{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T10:27:17Z","timestamp":1769509637870,"version":"3.49.0"},"reference-count":42,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"Study on Failure Mechanism and Protection Technology of Measurement Transfer for Primary and Secondary Fused Distribution Equipment","award":["5400-202355734A-3-3-JC"],"award-info":[{"award-number":["5400-202355734A-3-3-JC"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Access"],"published-print":{"date-parts":[[2023]]},"DOI":"10.1109\/access.2023.3339377","type":"journal-article","created":{"date-parts":[[2023,12,4]],"date-time":"2023-12-04T18:57:03Z","timestamp":1701716223000},"page":"140395-140405","source":"Crossref","is-referenced-by-count":1,"title":["Test and Analysis on Electromagnetic Disturbance of Digital Unit of Primary\u2013Secondary Integrated 10kV Circuit Breaker"],"prefix":"10.1109","volume":"11","author":[{"given":"Feiyan","family":"Zhou","sequence":"first","affiliation":[{"name":"China Electric Power Research Institute, Beijing, China"}]},{"given":"Yan","family":"Wu","sequence":"additional","affiliation":[{"name":"China Electric Power Research Institute, Beijing, China"}]},{"given":"Lingyun","family":"Gu","sequence":"additional","affiliation":[{"name":"China Electric Power Research Institute, Beijing, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1965-4210","authenticated-orcid":false,"given":"Dingyu","family":"Qin","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9459-4043","authenticated-orcid":false,"given":"Chongqing","family":"Jiao","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing, China"}]},{"given":"Zhanpeng","family":"Du","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing, China"}]},{"given":"Zuoxing","family":"Deng","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing, China"}]},{"given":"Zhiye","family":"Jiang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing, China"}]},{"given":"Jiancheng","family":"Huang","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Alternate Electrical Power System with Renewable Energy Source, North China Electric Power University, Beijing, China"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2017.2695490"},{"issue":"10","key":"ref2","first-page":"3387","article-title":"Analysis and simulated experiment for port disturbance voltage due to switching operation in GIS substation","volume":"43","author":"Wu","year":"2017","journal-title":"High Voltage Eng."},{"issue":"5","key":"ref3","first-page":"1709","article-title":"Measurement and analysis on electromagnetic disturbance of intelligent electronic device current transformer ports due to switching operations in a 500 kV gas insulated substation","volume":"41","author":"Liu","year":"2015","journal-title":"High Voltage Eng."},{"issue":"12","key":"ref4","first-page":"4483","article-title":"Electromagnetic disturbance coupling and suppression of on-site electronic device power port in substations","volume":"47","author":"Ge","year":"2021","journal-title":"High Voltage Eng."},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2007.901292"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2005.852362"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1049\/iet-gtd.2016.0292"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1049\/hve2.12121"},{"issue":"5","key":"ref9","first-page":"1686","article-title":"Analysis on electromagnetic compatibility immunity requirements for secondary equipment during switching transient operations in intelligent substation","volume":"41","author":"Zhao","year":"2015","journal-title":"High Voltage Eng."},{"issue":"4","key":"ref10","first-page":"1204","article-title":"Influence of disconnector in gas insulated switchgear switching on\/off on electromagnetic compatibility of electronic transformer","volume":"44","author":"Liu","year":"2018","journal-title":"High Voltage Eng."},{"key":"ref11","first-page":"54","article-title":"Interference analysis and protection of electronic current transformer caused by disconnect switch operation in GIS","volume":"52","author":"Bai","year":"2016","journal-title":"High Voltage App."},{"issue":"3","key":"ref12","first-page":"1016","article-title":"Electromagnetic compatibility detection system of electronic transformer based on disconnector switching operation","volume":"44","author":"Liu","year":"2018","journal-title":"High Voltage Eng."},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/MPER.1984.5525907"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/MPER.1984.5525908"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/61.19267"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/61.329519"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/61.329520"},{"issue":"1","key":"ref18","first-page":"269","article-title":"Research progress in electromagnetic disturbance characteristics and protection due to switching operations of primary and secondary integrated switchgear","volume":"48","author":"Wang","year":"2022","journal-title":"High Voltage Eng."},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2009.2034008"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/TEMC.2021.3064154"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.3390\/en13051130"},{"issue":"16","key":"ref22","first-page":"4935","article-title":"Research progress on transient electromagnetic disturbance due to switching operations in GIS substation","volume":"39","author":"Chen","year":"2019","journal-title":"Proc. CSEE"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.3389\/fenrg.2021.819021"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1109\/TEMC.2021.3049144"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.3390\/en15051849"},{"issue":"3","key":"ref26","first-page":"960","article-title":"Modeling and characteristic analysis of switching transient disturbance in substation","volume":"43","author":"Wang","year":"2017","journal-title":"High Voltage Eng."},{"issue":"4","key":"ref27","first-page":"1605","article-title":"Disturbance voltage statistical characteristics of secondary system under impulse current and its consistency with immunity test","volume":"45","author":"Li","year":"2021","journal-title":"Power Syst. Technol."},{"issue":"11","key":"ref28","first-page":"57","article-title":"Measurement and analysis of electromagnetic disturbance caused by switch operation of distribution switchgear","volume":"38","author":"Li","year":"2019","journal-title":"Eng. Des."},{"issue":"8","key":"ref29","first-page":"27","article-title":"The EMI study of pole-mounted switch\u2019s breaking on its secondary smart devices","volume":"30","author":"Li","year":"2015","journal-title":"Trans. China Electrotechnical Soc."},{"issue":"377","key":"ref30","first-page":"11","article-title":"Test and simulation of electromagnetic radiation interference during capacitive closing process of pole-mounted switch in distribution network","volume":"56","author":"Niu","year":"2020","journal-title":"High Voltage App."},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.3390\/s21237800"},{"issue":"4","key":"ref32","first-page":"74","article-title":"Study on electromagnetic interference of lightning shock to primary and secondary fusion set switches","volume":"41","author":"Chen","year":"2020","journal-title":"J. Zhengzhou Univ."},{"issue":"2","key":"ref33","first-page":"214","article-title":"Influence of lightning impulse voltage on measurement accuracy of power distribution primary and secondary fusion equipment","volume":"40","author":"He","year":"2020","journal-title":"Electric Power Autom. Equip."},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2020.2971107"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1109\/TEMC.2017.2761998"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2016.2600277"},{"issue":"8","key":"ref37","first-page":"29","article-title":"Measurement and analysis of electromagnetic disturbance on the intelligent component CT port due to 500 kV gas insulated substation breaker operations","volume":"52","author":"Zhang","year":"2016","journal-title":"High Voltage App."},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1109\/T-PAS.1977.32520"},{"key":"ref39","volume-title":"Testing and Measurement Techniques\u2014Damped Oscillatory Wave Immunity Test","year":"2019"},{"key":"ref40","volume-title":"Electromagnetic Compatibility (EMC)\u2014Part 6\u20135: Generic Standards-Immunity for Equipment Used in Power Station and Substation Environment","year":"2015"},{"key":"ref41","volume-title":"High-Voltage Switchgear and Controlgear\u2014Part 1: Common Specifications for Alternating Current Switchgear and Controlgear","year":"2017"},{"key":"ref42","volume-title":"Testing and Measurement Techniques\u2014Damped Oscillatory Magnetic Field Immunity Test","year":"2016"}],"container-title":["IEEE Access"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/6287639\/10005208\/10341224.pdf?arnumber=10341224","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,12]],"date-time":"2024-01-12T03:20:59Z","timestamp":1705029659000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10341224\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"references-count":42,"URL":"https:\/\/doi.org\/10.1109\/access.2023.3339377","relation":{},"ISSN":["2169-3536"],"issn-type":[{"value":"2169-3536","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023]]}}}