{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T14:09:07Z","timestamp":1784210947912,"version":"3.55.0"},"reference-count":21,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"State Grid Corporation of China Technology Project","award":["520940230004"],"award-info":[{"award-number":["520940230004"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Access"],"published-print":{"date-parts":[[2024]]},"DOI":"10.1109\/access.2024.3392851","type":"journal-article","created":{"date-parts":[[2024,4,23]],"date-time":"2024-04-23T19:38:22Z","timestamp":1713901102000},"page":"187471-187482","source":"Crossref","is-referenced-by-count":16,"title":["Dynamic Reactive Power Optimization Strategy for AC\/DC Hybrid Power Grid Considering Different Wind Power Penetration Levels"],"prefix":"10.1109","volume":"12","author":[{"given":"Nan","family":"Feng","sequence":"first","affiliation":[{"name":"State Grid Shanghai Electric Power Company Ltd., Electric Power Research Institute, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuyao","family":"Feng","sequence":"additional","affiliation":[{"name":"State Grid Shanghai Electric Power Company Ltd., Electric Power Research Institute, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2462-7073","authenticated-orcid":false,"given":"Yun","family":"Su","sequence":"additional","affiliation":[{"name":"State Grid Shanghai Electric Power Company Ltd., Electric Power Research Institute, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yajun","family":"Zhang","sequence":"additional","affiliation":[{"name":"State Grid Shanghai Electric Power Company Ltd., Electric Power Research Institute, Shanghai, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4461-9481","authenticated-orcid":false,"given":"Tao","family":"Niu","sequence":"additional","affiliation":[{"name":"Electrical Engineering Department, Chongqing University, Chongqing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.17775\/CSEEJPES.2022.01620"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2018.2800666"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1109\/POWERCON53785.2021.9697569"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.23919\/AEIT50178.2020.9241102"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1109\/IAECST54258.2021.9695739"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2022.3192489"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1007\/978-981-13-9779-0_21"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/TSTE.2022.3164923"},{"issue":"20","key":"ref9","first-page":"25","article-title":"Research on the impact of synchronous condensers on the operation of provincial-level power grids and control strategies","volume":"47","author":"Zhao","year":"2019","journal-title":"Protection Control Power Syst."},{"issue":"8","key":"ref10","first-page":"2961","article-title":"Research on multi-objective reactive power and voltage coordinated control system based on the new synchronous condensers","volume":"43","author":"Li","year":"2019","journal-title":"Power Syst. Technol."},{"issue":"11","key":"ref11","first-page":"21","article-title":"Coordinated voltage control strategy and simulation study of ultra high voltage AC\/DC hybrid power grid","volume":"42","author":"Chen","journal-title":"Protection Control Power Syst."},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/TASC.2012.2235132"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2011.2174387"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/TSTE.2023.3269532"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2007.907387"},{"issue":"10","key":"ref16","first-page":"37","article-title":"Study on reactive power optimization and voltage control of AC\/DC system based on simulated annealing genetic algorithm","volume":"44","author":"Huang","year":"2016","journal-title":"Protection Control Power Syst."},{"issue":"2","key":"ref17","first-page":"158","article-title":"Reactive power optimization of AC\/DC system based on singular value decomposition and interior point method","volume":"24","author":"Di","year":"2009","journal-title":"J. Electr. Eng."},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2014.2343625"},{"issue":"7","key":"ref19","first-page":"1150","article-title":"INNC method for solving multi-objective reactive power optimization of AC\/DC interconnected power grid","volume":"34","author":"Li","year":"2014","journal-title":"Proc. Chin. Soc. Electr. Eng."},{"issue":"9","key":"ref20","first-page":"119","article-title":"Multi-objective reactive power optimization control of AC\/DC system considering loss characteristics of converter stations","volume":"45","author":"Li","year":"2017","journal-title":"Protection Control Power Syst."},{"issue":"10","key":"ref21","first-page":"91","article-title":"Study on optimal point selection and capacity of reactive power compensation in AC\/DC power grid","volume":"45","author":"Liu","year":"2017","journal-title":"Protection Control Power Syst."}],"container-title":["IEEE Access"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/6287639\/10380310\/10506911.pdf?arnumber=10506911","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,15]],"date-time":"2025-01-15T20:09:34Z","timestamp":1736971774000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10506911\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":21,"URL":"https:\/\/doi.org\/10.1109\/access.2024.3392851","relation":{},"ISSN":["2169-3536"],"issn-type":[{"value":"2169-3536","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024]]}}}