{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T17:05:18Z","timestamp":1770743118212,"version":"3.49.0"},"reference-count":34,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Access"],"published-print":{"date-parts":[[2024]]},"DOI":"10.1109\/access.2024.3439684","type":"journal-article","created":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T17:53:24Z","timestamp":1723053204000},"page":"183999-184009","source":"Crossref","is-referenced-by-count":1,"title":["Study on the Triggered Discharge Characteristics of Sphere Gaps for Protecting Transformer Neutral Point"],"prefix":"10.1109","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8687-8612","authenticated-orcid":false,"given":"Hongyan","family":"Nie","sequence":"first","affiliation":[{"name":"Key Laboratory of Engineering Dielectrics and Its Application, Harbin University of Science and Technology, Harbin, China"}]},{"given":"Pengfei","family":"Wang","sequence":"additional","affiliation":[{"name":"Key Laboratory of Engineering Dielectrics and Its Application, Harbin University of Science and Technology, Harbin, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0028-8393","authenticated-orcid":false,"given":"Qingguo","family":"Chen","sequence":"additional","affiliation":[{"name":"Key Laboratory of Engineering Dielectrics and Its Application, Harbin University of Science and Technology, Harbin, China"}]},{"given":"Zhen","family":"An","sequence":"additional","affiliation":[{"name":"Wujiang Transformer Factory Company Ltd, Suzhou, China"}]},{"given":"Zhixun","family":"Li","sequence":"additional","affiliation":[{"name":"Key Laboratory of Engineering Dielectrics and Its Application, Harbin University of Science and Technology, Harbin, China"}]}],"member":"263","reference":[{"key":"ref1","volume-title":"Technical Code for Relaying Protection and Security Automatic Equipment, GB\/T Standard 14285","year":"2023"},{"key":"ref2","first-page":"26","article-title":"A new controllable gap in parallel with MOA at 110 kV and 220 kV transformer neutral-point without earthing","volume-title":"Proc. Asia\u2013Pacific Int. Conf. Lightning","author":"Chen"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2016.2606365"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1109\/ICPES56491.2022.10073131"},{"key":"ref5","volume-title":"Insulation Co-Ordination\u2014Part1: Definitions, Principles and Rules, IEC Standard 60071-1","year":"2019"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/ICPES53652.2021.9683842"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/APEC48139.2024.10509435"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/appeec.2012.6307360"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1109\/ISGT-Europe54678.2022.9960344"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1109\/APL.2019.8815979"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2005.861319"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2022.3147014"},{"issue":"2","key":"ref13","first-page":"243","article-title":"New composite gap for protection at 110 kV and 220 kV transformer neutrals","volume":"34","author":"Peng","year":"2008","journal-title":"High Voltage Eng."},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2020.3027960"},{"issue":"2","key":"ref15","first-page":"699","article-title":"A new rod-plate-rod combined protection gap for 110 kV transformer neutral point","volume":"41","author":"Yan","year":"2015","journal-title":"High Voltage Eng."},{"issue":"7","key":"ref16","first-page":"1786","article-title":"Mathematical analysis on power frequency discharge characteristic of air-water two-phase flow combined protection gap for transformer neutral points","volume":"37","author":"Li","year":"2014","journal-title":"Power Sys. Tech."},{"issue":"12","key":"ref17","first-page":"1989","article-title":"Research on power frequency discharge characteristics and mechanism of the protection gap of the combined fluid of air and water used on transformer neutral points","volume":"34","author":"Li","year":"2014","journal-title":"Proc. CSEE"},{"issue":"3","key":"ref18","first-page":"772","article-title":"Protection mode of parallel connection of water flow protection gap and arrester for neutral points of 110 kV power transformers","volume":"40","author":"Li","year":"2014","journal-title":"High Voltage Eng."},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/1601\/4\/042030"},{"issue":"2","key":"ref20","first-page":"57","article-title":"Ttiggering controlled discharge gap used for protection of neutral point of power transformer in 110 kV power system","volume":"18","author":"Wang","year":"2013","journal-title":"J. Harbin Univ. Scien. Tech."},{"key":"ref21","first-page":"2295","article-title":"Breakdown characteristics and gap distance standardization of neutral point gap in 110 kV and 220 kV transformers","volume-title":"Proc. Int. Conf. Power Syst. Technol., Carbon Neutrality New Type Power Syst.","author":"Liu"},{"key":"ref22","first-page":"1","article-title":"110 kV and 220 kV transformer neutral point gap and arrester standardization and relay protection configuration","volume-title":"Proc. Int. Conf. Power Syst. Technol. (POWERCON)","author":"Han"},{"key":"ref23","first-page":"360","article-title":"Selection method of neutral point overvoltage protection for 220 kV transformer","volume-title":"Proc. IEEE PES Innov. Smart Grid Technol. Asia","author":"Wang"},{"issue":"2","key":"ref24","first-page":"45","article-title":"Sparkover voltage estimation of standard sphere gaps for negative polarity by calculation of ionization index","volume":"18","author":"Nishikori","year":"2004","journal-title":"KIEE Int. Trans. EA"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1109\/TMAG.2021.3074035"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1541\/ieejfms.137.184"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1002\/tee.23750"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1002\/eej.1165"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2019.2927159"},{"key":"ref30","volume-title":"Voltage Measurement By Means of Standard Air Gaps","year":"2002"},{"key":"ref31","volume-title":"High-Voltage Test Techniques\u2014Part 1: General Definitions and Test Requirements, IEC Standard 60060-1","year":"2010"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1088\/2058-6272\/ad0c1c"},{"key":"ref33","first-page":"2016","article-title":"100 millimeters sphere-gap with non uniform field electrodes triggered gaps","volume-title":"Proc. Appl. Mech. Mater.","author":"Suksamosorn"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1109\/TPS.2023.3310523"}],"container-title":["IEEE Access"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx8\/6287639\/10380310\/10630513.pdf?arnumber=10630513","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,15]],"date-time":"2025-01-15T20:11:49Z","timestamp":1736971909000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10630513\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024]]},"references-count":34,"URL":"https:\/\/doi.org\/10.1109\/access.2024.3439684","relation":{},"ISSN":["2169-3536"],"issn-type":[{"value":"2169-3536","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024]]}}}