{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T18:10:13Z","timestamp":1775067013015,"version":"3.50.1"},"reference-count":24,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"Qingdao Huanghai University Doctoral Research Foundation Project","award":["2023boshi09"],"award-info":[{"award-number":["2023boshi09"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Access"],"published-print":{"date-parts":[[2025]]},"DOI":"10.1109\/access.2025.3594570","type":"journal-article","created":{"date-parts":[[2025,7,31]],"date-time":"2025-07-31T18:33:44Z","timestamp":1753986824000},"page":"152046-152062","source":"Crossref","is-referenced-by-count":1,"title":["A Novel Contactless Approach to Continuous Blood Pressure Monitoring Using Complex CEEMDAN and Neural Networks"],"prefix":"10.1109","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-0415-2558","authenticated-orcid":false,"given":"Ketao","family":"Ma","sequence":"first","affiliation":[{"name":"Qingdao Huanghai University, Qingdao, Shandong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8270-4500","authenticated-orcid":false,"given":"Yiyan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Qingdao Huanghai University, Qingdao, Shandong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Baohua","family":"Shan","sequence":"additional","affiliation":[{"name":"Qingdao Huanghai University, Qingdao, Shandong, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"issue":"10","key":"ref1","doi-asserted-by":"crossref","first-page":"2113","DOI":"10.3390\/healthcare10102113","article-title":"Blood pressure measurement: From cuff-based to contactless monitoring","volume":"10","author":"Man","year":"2022","journal-title":"Healthcare"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1109\/JBHI.2022.3172514"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/s10916-016-0439-z"},{"issue":"18","key":"ref4","doi-asserted-by":"crossref","first-page":"6022","DOI":"10.3390\/s21186022","article-title":"Assessment of non-invasive blood pressure prediction from PPG and rPPG signals using deep learning","volume":"21","author":"Schrumpf","year":"2021","journal-title":"Sensors"},{"issue":"3","key":"ref5","doi-asserted-by":"crossref","first-page":"619","DOI":"10.3390\/s25030619","article-title":"Accurate cardiac duration detection for remote blood pressure estimation using mm-wave Doppler radar","volume":"25","author":"Wang","year":"2025","journal-title":"Sensors"},{"issue":"14","key":"ref6","doi-asserted-by":"crossref","first-page":"6517","DOI":"10.3390\/s23146517","article-title":"Remote estimation of blood pressure using millimeter-wave frequency-modulated continuous-wave radar","volume":"23","author":"Singh","year":"2023","journal-title":"Sensors"},{"key":"ref7","first-page":"1413","article-title":"Non-contact beat-to-beat blood pressure measurement using continuous wave Doppler radar","volume-title":"IEEE MTT-S Int. Microw. Symp. Dig.","author":"Zhao"},{"issue":"23","key":"ref8","doi-asserted-by":"crossref","first-page":"39383","DOI":"10.1109\/JSEN.2024.3476130","article-title":"Noncontact blood pressure estimation from the carotid pulse wave signal using a modified ResNet-18 network with LFMCW radar","volume":"24","author":"Zhao","year":"2024","journal-title":"IEEE Sensors J."},{"key":"ref9","first-page":"1","article-title":"On models and approaches for human vital signs extraction from short range radar signals","volume-title":"Proc. 14th Eur. Conf. Antennas Propag. (EuCAP)","author":"Czerkawski"},{"issue":"4","key":"ref10","doi-asserted-by":"crossref","first-page":"1718","DOI":"10.1109\/TMTT.2013.2249525","article-title":"Data-based quadrature imbalance compensation for a CW Doppler radar system","volume":"61","author":"Singh","year":"2013","journal-title":"IEEE Trans. Microw. Theory Techn."},{"key":"ref11","doi-asserted-by":"crossref","first-page":"74033","DOI":"10.1109\/ACCESS.2022.3190355","article-title":"Non-contact heart rate monitoring based on millimeter wave radar","volume":"10","author":"Ling","year":"2022","journal-title":"IEEE Access"},{"issue":"12","key":"ref12","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1109\/LSP.2007.904710","article-title":"Bivariate empirical mode decomposition","volume":"14","author":"Rilling","year":"2007","journal-title":"IEEE Signal Process. Lett."},{"key":"ref13","first-page":"4144","article-title":"A complete ensemble empirical mode decomposition with adaptive noise","volume-title":"Proc. IEEE Int. Conf. Acoust., Speech Signal Process. (ICASSP)","author":"Torres"},{"issue":"1","key":"ref14","first-page":"33230","article-title":"A simple adaptive transfer function for deriving the central blood pressure waveform from a radial blood pressure waveform","volume-title":"Sci. Rep.","volume":"6","author":"Gao","year":"2016"},{"issue":"12","key":"ref15","doi-asserted-by":"crossref","first-page":"3299","DOI":"10.1109\/TIM.2017.2745081","article-title":"Nonlinear cuffless blood pressure estimation of healthy subjects using pulse transit time and arrival time","volume":"66","author":"Esmaili","year":"2017","journal-title":"IEEE Trans. Instrum. Meas."},{"issue":"1","key":"ref16","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1038\/s41597-020-00629-5","article-title":"A dataset of clinically recorded radar vital signs with synchronised reference sensor signals","volume":"7","author":"Schellenberger","year":"2020","journal-title":"Sci. Data"},{"issue":"11","key":"ref17","doi-asserted-by":"crossref","first-page":"2492","DOI":"10.3390\/s19112492","article-title":"A clinically evaluated interferometric continuous-wave radar system for the contactless measurement of human vital parameters","volume":"19","author":"Michler","year":"2019","journal-title":"Sensors"},{"issue":"24","key":"ref18","doi-asserted-by":"crossref","first-page":"9680","DOI":"10.3390\/s23249680","article-title":"TRCCBP: Transformer network for radar-based contactless continuous blood pressure monitoring","volume":"23","author":"Jiang","year":"2023","journal-title":"Sensors"},{"issue":"8","key":"ref19","doi-asserted-by":"crossref","first-page":"4553","DOI":"10.1109\/JBHI.2024.3400961","article-title":"Non-contact blood pressure estimation from radar signals by a stacked deformable convolution network","volume":"28","author":"Qiu","year":"2024","journal-title":"IEEE J. Biomed. Health Informat."},{"issue":"6","key":"ref20","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1109\/10.764946","article-title":"Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry","volume":"46","author":"Fetics","year":"1999","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1161\/01.hyp.0000223013.60612.72"},{"issue":"7","key":"ref22","doi-asserted-by":"crossref","first-page":"1524","DOI":"10.1109\/TBME.2016.2612639","article-title":"Estimation of pulse transit time as a function of blood pressure using a nonlinear arterial tube-load model","volume":"64","author":"Gao","year":"2017","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"ref23","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2023.1280899","article-title":"Estimation of central blood pressure waveform from femoral blood pressure waveform by blind sources separation","volume":"10","author":"Gbaoui","year":"2023","journal-title":"Frontiers Cardiovascular Med."},{"issue":"2","key":"ref24","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1109\/TBME.2023.3307658","article-title":"A physical model-based approach to one-point calibration of pulse transit time to blood pressure","volume":"71","author":"Mousavi","year":"2024","journal-title":"IEEE Trans. Biomed. Eng."}],"container-title":["IEEE Access"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx8\/6287639\/10820123\/11105460.pdf?arnumber=11105460","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T17:47:23Z","timestamp":1757353643000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/11105460\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"references-count":24,"URL":"https:\/\/doi.org\/10.1109\/access.2025.3594570","relation":{},"ISSN":["2169-3536"],"issn-type":[{"value":"2169-3536","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025]]}}}