{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,29]],"date-time":"2024-10-29T11:02:22Z","timestamp":1730199742685,"version":"3.28.0"},"reference-count":10,"publisher":"IEEE","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,3]]},"DOI":"10.1109\/bhi.2018.8333361","type":"proceedings-article","created":{"date-parts":[[2018,4,9]],"date-time":"2018-04-09T21:11:30Z","timestamp":1523308290000},"page":"25-28","source":"Crossref","is-referenced-by-count":6,"title":["Non-contact measurements of diaphragm electromyogram, electrocardiogram and respiratory variations with sheet-type fabric electrodes for neonatal monitoring"],"prefix":"10.1109","author":[{"given":"Hayato","family":"Uesawa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomoya","family":"Takehara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akinori","family":"Ueno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.14326\/abe.6.28"},{"key":"ref3","first-page":"30","author":"fukuda","year":"1958","journal-title":"Infants Surgery"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"14732","DOI":"10.3390\/s140814732","article-title":"Flexible capacitive electrodes for minimizing motion artifacts in ambulatory electrocardiograms","volume":"14","author":"lee","year":"2014","journal-title":"SENSORS"},{"key":"ref6","first-page":"364","article-title":"Suppression of common-mode noise and signal saturation in non-contact in-bed electrocardiogram measurement using laminated feedback electrode","author":"takano","year":"2017","journal-title":"Proc Conf"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC.2013.6609560"},{"key":"ref8","first-page":"5","article-title":"A study on breath detection algorithm for capacitive in-bed cardiorespiratory monitor","volume":"115","author":"yamagishi","year":"2016","journal-title":"IECE Technical Report"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2008.4649665"},{"key":"ref2","first-page":"42","article-title":"Unrestrained facile measurement of narrow-band ECG and respiratory variation in infants with a capacitive sheet-type sensor","volume":"47","author":"yama","year":"2009","journal-title":"Trans Japan Soc Med Biol Eng"},{"key":"ref9","first-page":"30","article-title":"Photoplethysmography for Simultaneous Monitoring of Heart and Respiratory Rates Using Digital Filters","volume":"31","author":"nakajima","year":"1993","journal-title":"Med Biol Eng"},{"key":"ref1","first-page":"98","article-title":"Neonatology introduction","author":"nishida","year":"2012","journal-title":"4th ed Tokyo Igaku-Shoin Ltd"}],"event":{"name":"2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI)","start":{"date-parts":[[2018,3,4]]},"location":"Las Vegas, NV, USA","end":{"date-parts":[[2018,3,7]]}},"container-title":["2018 IEEE EMBS International Conference on Biomedical &amp; Health Informatics (BHI)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/8328660\/8333343\/08333361.pdf?arnumber=8333361","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,26]],"date-time":"2022-01-26T05:03:54Z","timestamp":1643173434000},"score":1,"resource":{"primary":{"URL":"http:\/\/ieeexplore.ieee.org\/document\/8333361\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3]]},"references-count":10,"URL":"https:\/\/doi.org\/10.1109\/bhi.2018.8333361","relation":{},"subject":[],"published":{"date-parts":[[2018,3]]}}}