{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,29]],"date-time":"2024-10-29T16:21:25Z","timestamp":1730218885196,"version":"3.28.0"},"reference-count":14,"publisher":"IEEE","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,7]]},"DOI":"10.1109\/embc.2013.6609994","type":"proceedings-article","created":{"date-parts":[[2013,10,1]],"date-time":"2013-10-01T18:37:56Z","timestamp":1380652676000},"page":"2287-2290","source":"Crossref","is-referenced-by-count":3,"title":["Local Pulse Wave Velocity estimation using Magnetic Plethysmograph"],"prefix":"10.1109","author":[{"given":"Anand","family":"Chandrasekhar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jayaraj","family":"Joseph","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohanasankar","family":"Sivaprakasam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"13","doi-asserted-by":"publisher","DOI":"10.1109\/IECBES.2010.5742222"},{"journal-title":"Carotid Artery Pulse Wave Velocity Measurement by Cardiovascular Magnetic Resonance","year":"2006","author":"keenan","key":"14"},{"key":"11","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC.2012.6345909"},{"key":"12","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC.2012.6346144"},{"key":"3","first-page":"282","article-title":"Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger","volume":"3","author":"boehmer","year":"1987","journal-title":"Journal of Clinical Monitoring"},{"key":"2","doi-asserted-by":"publisher","DOI":"10.1038\/jhh.2008.42"},{"key":"1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehl254"},{"key":"10","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.219.2.r01ap40551"},{"key":"7","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(03)00416-8"},{"key":"6","doi-asserted-by":"publisher","DOI":"10.1161\/01.HYP.26.3.485"},{"key":"5","first-page":"2","article-title":"A novel method for measurement of pulse wave velocity by dual-channel photoplethysmography","author":"wu","year":"2004","journal-title":"Biomedical Circuits and Systems 2004 IEEE International Workshop on"},{"key":"4","first-page":"6907","article-title":"Initial study on pulse wave velocity acquired from one hand using two synchronized wireless reflectance pulse oximeters","author":"li","year":"2011","journal-title":"Engineering in Medicine and Biology Society EMBC 2011 Annual International Conference of the IEEE"},{"key":"9","doi-asserted-by":"publisher","DOI":"10.1016\/S0895-7061(00)00707-X"},{"key":"8","doi-asserted-by":"publisher","DOI":"10.1088\/0143-0815\/10\/2\/002"}],"event":{"name":"2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","start":{"date-parts":[[2013,7,3]]},"location":"Osaka","end":{"date-parts":[[2013,7,7]]}},"container-title":["2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/6596169\/6609410\/06609994.pdf?arnumber=6609994","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,3,22]],"date-time":"2017-03-22T17:15:51Z","timestamp":1490202951000},"score":1,"resource":{"primary":{"URL":"http:\/\/ieeexplore.ieee.org\/document\/6609994\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7]]},"references-count":14,"URL":"https:\/\/doi.org\/10.1109\/embc.2013.6609994","relation":{},"subject":[],"published":{"date-parts":[[2013,7]]}}}