{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,29]],"date-time":"2024-10-29T19:13:16Z","timestamp":1730229196722,"version":"3.28.0"},"reference-count":51,"publisher":"IEEE","license":[{"start":{"date-parts":[[2019,7,1]],"date-time":"2019-07-01T00:00:00Z","timestamp":1561939200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"},{"start":{"date-parts":[[2019,7,1]],"date-time":"2019-07-01T00:00:00Z","timestamp":1561939200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2019,7,1]],"date-time":"2019-07-01T00:00:00Z","timestamp":1561939200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,7]]},"DOI":"10.1109\/icarm.2019.8833890","type":"proceedings-article","created":{"date-parts":[[2019,9,13]],"date-time":"2019-09-13T00:27:41Z","timestamp":1568334461000},"page":"475-480","source":"Crossref","is-referenced-by-count":4,"title":["The Prosthetic Arm: A Dramatic Improvement For The Limb Amputation From The Humerus"],"prefix":"10.1109","author":[{"given":"Guoxin","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yueyue","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhijun","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2008.2005942"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2009.116"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1080\/03091900210142459"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1007\/s00422-006-0124-2"},{"key":"ref31","article-title":"The Intrinsic Handa 22 degree-of-freedom artificial hand-wrist replacement","author":"weir","year":"2008","journal-title":"MEC08 measuring success in upper limb prosthetics University of New Brunswicks myoelectric controls\/powered prosthetics symposium"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2004.00014.x"},{"key":"ref37","first-page":"723729","article-title":"Use and satisfaction with prosthetic limb devices and related services","volume":"85","author":"pezzin","year":"2004","journal-title":"Arch Phys Med Rehabil"},{"key":"ref36","first-page":"32.132.61","article-title":"Design of artificial arms and hands for prosthetic applications","author":"weir","year":"2003","journal-title":"Standard Handbook of Biomedical Engineering and Design"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2008.923917"},{"key":"ref34","first-page":"173193","article-title":"Control of limb prostheses","volume":"3","author":"childress","year":"2004","journal-title":"Atlas of Amputations and Limb Deficiencies"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2009.2033113"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1177\/0309364613506913"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2010.5626225"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jelekin.2006.08.006"},{"key":"ref1","first-page":"12681270","article-title":"A Russian bioelectric-controlled prosthesis","volume":"91","author":"sherman","year":"1964","journal-title":"Can Med Assoc J"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"143163","DOI":"10.1023\/B:AURO.0000016862.38337.f1","article-title":"The MANUS-HAND dextrous robotics upper limb prothesis: Mechanical and manipulation aspects","volume":"16","author":"pons","year":"2004","journal-title":"Auton Robots"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1109\/IROS.2008.4650628"},{"key":"ref21","first-page":"36923697","article-title":"Multisensory five-fingered dexterous hand: The DLR\/ HIT Hand II","volume":"2226","author":"h","year":"0","journal-title":"Proc IEEE\/RSJ Int Conf Intell Robots Syst"},{"key":"ref24","first-page":"207216","article-title":"An overview of the developmental process for the modular prosthetic limb","volume":"30","author":"johannes","year":"2011","journal-title":"Johns Hopkins APL Tech Digest"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1017\/S0263574701003538"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.2010.07.0127"},{"key":"ref25","first-page":"14","article-title":"Design considerations in upper extremity prostheses","volume":"11","author":"altobelli","year":"2011","journal-title":"Symposium Proceedings MEC"},{"key":"ref50","doi-asserted-by":"publisher","DOI":"10.1126\/scirobotics.aau8892"},{"key":"ref51","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.3006820"},{"journal-title":"Bebionic Grip Patterns","year":"2012","key":"ref10"},{"journal-title":"iLimb Ultra","year":"2012","key":"ref11"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.1109\/10.914793"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/ICORR.2011.5975476"},{"journal-title":"iLimb Ultra Revolution","year":"2013","key":"ref13"},{"key":"ref14","article-title":"First experiences with the Vincent Hand","author":"schulz","year":"2011","journal-title":"Myoelectr Controls Symp"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2009.2033113"},{"key":"ref16","article-title":"An overview of the UNB hand system, presented at the Myoelectr","author":"losier","year":"0","journal-title":"Controls\/Powered Prosthetics Symp"},{"key":"ref17","article-title":"Mechanical design of a multifunction hand prosthesis system The UNB Hand","author":"clawson a","year":"0","journal-title":"13th World Congr"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1109\/ICORR.2013.6650441"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1186\/1743-0003-8-29"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1109\/RBME.2010.2085429"},{"key":"ref3","first-page":"275294","article-title":"Myoelectric control systemsA survey","volume":"2","author":"oskoei","year":"2007","journal-title":"Biomed Signal Process Control"},{"key":"ref6","first-page":"326334","article-title":"The Southampton Hand: an intelligent myoelectric prosthesis","volume":"31","author":"kyberd","year":"1994","journal-title":"J Rehabil Res Dev"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.2010.08.0161"},{"journal-title":"Touch Bionics","year":"0","key":"ref8"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2002.1011247"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.aao6990"},{"journal-title":"Michelangelo Hand","year":"0","key":"ref9"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-015-0044-2"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1080\/03093640600994581"},{"key":"ref48","first-page":"346357","article-title":"Consumer design priorities for upper limb prosthetics","volume":"2","author":"biddiss","year":"2006","journal-title":"Disabil Rehabil Assist Technol"},{"key":"ref47","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1097\/00008526-199600810-00003","article-title":"Epidemiologic overview of individuals with upper-limb loss and their reported research priorities","volume":"8","author":"atkins","year":"1996","journal-title":"J Prosthet Orthot"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2013.2260172"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1186\/1743-0003-7-16"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1109\/RBME.2010.2085429"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2011.2175488"}],"event":{"name":"2019 IEEE 4th International Conference on Advanced Robotics and Mechatronics (ICARM)","start":{"date-parts":[[2019,7,3]]},"location":"Toyonaka, Japan","end":{"date-parts":[[2019,7,5]]}},"container-title":["2019 IEEE 4th International Conference on Advanced Robotics and Mechatronics (ICARM)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/8826169\/8833630\/08833890.pdf?arnumber=8833890","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,19]],"date-time":"2022-07-19T20:18:07Z","timestamp":1658261887000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/8833890\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7]]},"references-count":51,"URL":"https:\/\/doi.org\/10.1109\/icarm.2019.8833890","relation":{},"subject":[],"published":{"date-parts":[[2019,7]]}}}