{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,29]],"date-time":"2024-10-29T20:34:18Z","timestamp":1730234058816,"version":"3.28.0"},"reference-count":31,"publisher":"IEEE","license":[{"start":{"date-parts":[[2021,7,6]],"date-time":"2021-07-06T00:00:00Z","timestamp":1625529600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2021,7,6]],"date-time":"2021-07-06T00:00:00Z","timestamp":1625529600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,7,6]]},"DOI":"10.1109\/icccnt51525.2021.9579952","type":"proceedings-article","created":{"date-parts":[[2021,11,3]],"date-time":"2021-11-03T15:29:48Z","timestamp":1635953388000},"page":"1-5","source":"Crossref","is-referenced-by-count":1,"title":["A Curvature Based Approach for the Identification of Tortuous Blood Vessels in Retinal images of Preterm Infants"],"prefix":"10.1109","author":[{"given":"Unnikrishnan M","family":"S","sequence":"first","affiliation":[{"name":"College of Engineering,Department of Electronics and Communication Engineering,Trivandrum,Kerala"}]},{"given":"Bejoy","family":"Abraham","sequence":"additional","affiliation":[{"name":"College of Engineering,Department of Computer Science and Engineering,Perumon,Kerala"}]},{"given":"Sivakumar","family":"Ramachandran","sequence":"additional","affiliation":[{"name":"College of Engineering,Department of Electronics and Communication Engineering,Trivandrum,Kerala"}]}],"member":"263","reference":[{"key":"ref31","doi-asserted-by":"crossref","first-page":"3577","DOI":"10.1167\/iovs.07-1353","article-title":"Computerized analysis of retinal vessel width and tortuosity in premature infants","volume":"49","author":"clare","year":"2008","journal-title":"Investigative Ophthalmology & Visual Science"},{"key":"ref30","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.jaapos.2007.04.008","article-title":"A pilot study using &#x201C;roptool&#x201D; to quantify plus disease in retinopathy of prematurity","volume":"11","author":"david","year":"2007","journal-title":"Journal of American Association for Pediatric Ophthalmology and Strabismus"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/S1361-8415(02)00058-0"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2006.07.008"},{"key":"ref12","first-page":"560","article-title":"Magnetic-Measuring Square in the Measurement of the Circular Curve of Rail Transport Tracks Sensors","volume":"20","author":"kampczyk","year":"2020","journal-title":"Multidisciplinary Digital Publishing Institute"},{"journal-title":"Clinical Ophthalmology A Systematic Approach","year":"2011","author":"kanski","key":"ref13"},{"key":"ref14","article-title":"Computer-assisted measurement of retinal vascular width and tortuosity in retinopathy of prematurity","volume":"128","author":"amanda","year":"2010","journal-title":"Archives of Ophthalmology"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC.2014.6944850"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.jaapos.2010.03.006","article-title":"Retinal arterial but not venous tortuosity correlates with facioscapulohumeral muscular dystrophy severity","volume":"14","author":"susannah","year":"2010","journal-title":"Journal of American Association for Pediatric Ophthalmology and Strabismus"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1007\/BF00414653"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.3.4.044505"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1109\/INECCE.2011.5953872"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2010.2050771"},{"journal-title":"Oxford English Dictionary Oxford english dictionary","year":"1989","key":"ref4"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1159\/000158993"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2003.816964"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-0646"},{"key":"ref29","article-title":"Curvature-based tortuosity evaluation for infant retinal images","volume":"2","author":"turior","year":"2012","journal-title":"Journal of Information Engineering and Applications"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2004.07.001"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2007.904657"},{"key":"ref7","first-page":"181","article-title":"Adris: an automatic diabetic retinal image screening system","volume":"60","author":"guan goh","year":"2001","journal-title":"Studies in Fuzziness and Soft Computing"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00414652"},{"key":"ref9","article-title":"Measurement and classification of retinal vascular tortuosity","volume":"53","author":"william","year":"1999","journal-title":"International Journal of Medical Informatics"},{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02150097"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC.2012.6347105"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1007\/s00521-019-04697-6"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1016\/j.bbe.2021.02.005"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1109\/ISED.2016.7977093"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2011.01.008"},{"key":"ref26","first-page":"503","article-title":"A curvature based approach for the automated screening of retinopathy of prematurity in preterm infants","author":"sivakumar","year":"0","journal-title":"2017 13th International Conference on Signal-Image Technology & Internet-Based Systems (SITIS)"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1109\/ICIINFS.2016.8262975"}],"event":{"name":"2021 12th International Conference on Computing Communication and Networking Technologies (ICCCNT)","start":{"date-parts":[[2021,7,6]]},"location":"Kharagpur, India","end":{"date-parts":[[2021,7,8]]}},"container-title":["2021 12th International Conference on Computing Communication and Networking Technologies (ICCCNT)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/9579467\/9579470\/09579952.pdf?arnumber=9579952","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,2]],"date-time":"2022-08-02T19:43:04Z","timestamp":1659469384000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/9579952\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,6]]},"references-count":31,"URL":"https:\/\/doi.org\/10.1109\/icccnt51525.2021.9579952","relation":{},"subject":[],"published":{"date-parts":[[2021,7,6]]}}}