{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,22]],"date-time":"2025-03-22T11:41:45Z","timestamp":1742643705473,"version":"3.37.3"},"reference-count":26,"publisher":"IEEE","license":[{"start":{"date-parts":[[2021,5,30]],"date-time":"2021-05-30T00:00:00Z","timestamp":1622332800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"},{"start":{"date-parts":[[2021,5,30]],"date-time":"2021-05-30T00:00:00Z","timestamp":1622332800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2021,5,30]],"date-time":"2021-05-30T00:00:00Z","timestamp":1622332800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"funder":[{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,5,30]]},"DOI":"10.1109\/icra48506.2021.9561959","type":"proceedings-article","created":{"date-parts":[[2021,10,20]],"date-time":"2021-10-20T00:28:35Z","timestamp":1634689715000},"page":"12588-12594","source":"Crossref","is-referenced-by-count":7,"title":["A Haptic Mouse Design with Stiffening Muscle Layer for Simulating Guarding in Abdominal Palpation Training"],"prefix":"10.1109","author":[{"given":"Liang","family":"He","sequence":"first","affiliation":[]},{"given":"Florence","family":"Leong","sequence":"additional","affiliation":[]},{"given":"Thilina Dulantha","family":"Lalitharatne","sequence":"additional","affiliation":[]},{"given":"Simon","family":"de Lusignan","sequence":"additional","affiliation":[]},{"given":"Thrishantha","family":"Nanayakkara","sequence":"additional","affiliation":[]}],"member":"263","reference":[{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1109\/TOH.2010.2"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/TOH.2010.19"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/MRA.2016.2582718"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/VRAIS.1993.380769"},{"year":"2020","key":"ref14","article-title":"Touch (haptic device, 3d systems)"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1088\/0964-1726\/23\/9\/095007"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/TOH.2015.2391093"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC.2018.8512709"},{"key":"ref18","first-page":"1","article-title":"An abdominal phantom with tunable stiffness nodules and force sensing capability for palpation training","author":"he","year":"2020","journal-title":"IEEE Transactions on Robotics"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2020.2980114"},{"key":"ref4","first-page":"444","article-title":"A survey of simulators for palpation training","volume":"142","author":"zhang","year":"2009","journal-title":"Studies in Health Technology and Informatics"},{"journal-title":"Physical Examination & Health Assessment","year":"2015","author":"jarvis","key":"ref3"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2020.3041173"},{"key":"ref5","article-title":"Inspection, auscultation, palpation, and percussion of the abdomen","author":"ferguson","year":"1990","journal-title":"Clinical Methods The History Physical and Laboratory Examinations"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1080\/01421590802206747"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1145\/2962723"},{"key":"ref2","first-page":"473","article-title":"Inspection, auscultation, palpation, and percussion of the abdomen","author":"ferguson","year":"1990","journal-title":"Clinical Methods The History Physical and Laboratory Examinations"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.2147\/IJGM.S25936"},{"journal-title":"Bates&#x2019; Guide to Physical Examination and History-Taking","year":"2012","author":"bickley","key":"ref1"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/LRA.2020.3048670"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1109\/LRA.2019.2905980"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1089\/soro.2014.0002"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1016\/0028-3932(71)90067-4"},{"key":"ref23","article-title":"Design and analysis of jammable granular systems","author":"cheng","year":"2013","journal-title":"Ph D Dissertation"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0237379"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.3390\/act9040104"}],"event":{"name":"2021 IEEE International Conference on Robotics and Automation (ICRA)","start":{"date-parts":[[2021,5,30]]},"location":"Xi'an, China","end":{"date-parts":[[2021,6,5]]}},"container-title":["2021 IEEE International Conference on Robotics and Automation (ICRA)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/9560720\/9560666\/09561959.pdf?arnumber=9561959","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,10]],"date-time":"2022-05-10T15:47:08Z","timestamp":1652197628000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/9561959\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,30]]},"references-count":26,"URL":"https:\/\/doi.org\/10.1109\/icra48506.2021.9561959","relation":{},"subject":[],"published":{"date-parts":[[2021,5,30]]}}}