{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T16:55:53Z","timestamp":1773334553971,"version":"3.50.1"},"reference-count":16,"publisher":"IEEE","license":[{"start":{"date-parts":[[2025,11,26]],"date-time":"2025-11-26T00:00:00Z","timestamp":1764115200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2025,11,26]],"date-time":"2025-11-26T00:00:00Z","timestamp":1764115200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,11,26]]},"DOI":"10.1109\/icsrs68021.2025.11422171","type":"proceedings-article","created":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T19:36:03Z","timestamp":1773257763000},"page":"220-226","source":"Crossref","is-referenced-by-count":0,"title":["Belief Reliability Modeling and Analysis for Motion Accuracy of the UHV DC Disconnector Mechanism"],"prefix":"10.1109","author":[{"given":"Pengxiang","family":"Zhou","sequence":"first","affiliation":[{"name":"State Grid Corporation of China,DC Technology Center,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lechao","family":"Hao","sequence":"additional","affiliation":[{"name":"Beihang University,School of Reliability and Systems Engineering,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lindong","family":"Chai","sequence":"additional","affiliation":[{"name":"Beihang University,School of Reliability and Systems Engineering,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shiwei","family":"Li","sequence":"additional","affiliation":[{"name":"Beihang University,School of Reliability and Systems Engineering,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenhua","family":"Deng","sequence":"additional","affiliation":[{"name":"Hunan changgao high voltage switchgear Co., Ltd.,Technical Department,Changsha,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Zhang","sequence":"additional","affiliation":[{"name":"Beihang University,School of Reliability and Systems Engineering,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref1","volume-title":"Ultra High Voltage AC&DC Grid.","author":"Liu","year":"2013"},{"issue":"10","key":"ref2","first-page":"93","article-title":"Cause analysis and treatment of common faults of outdoor high-voltage disconnector","volume":"46","author":"Sheng","year":"2010","journal-title":"High Volt. Appar."},{"issue":"4","key":"ref3","first-page":"34","article-title":"Research on kinematic analysis and assembly method of GW4 type disconnector","volume":"54","author":"Zhao","year":"2018","journal-title":"High Volt. Appar."},{"issue":"4","key":"ref4","first-page":"134","article-title":"Path-analysis on opening and closing circuit of GW4 disconnector and optimization improvements","volume":"49","author":"Chang","year":"2013","journal-title":"High Volt. Appar."},{"issue":"1","key":"ref5","first-page":"93","article-title":"Optimal design of the conductor leader movement mechanism in the outdoors high-voltage disconnector","author":"Qin","year":"2006","journal-title":"Mach. Des. Res."},{"issue":"3","key":"ref6","first-page":"32","article-title":"Error analysis for transmission mechanism of disconnector","volume":"54","author":"Li","year":"2018","journal-title":"High Volt. Appar."},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1007\/978-981-16-0823-0"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.mechmachtheory.2008.08.003"},{"key":"ref9","first-page":"58","article-title":"Wear theory and mechanisms","volume":"1980","author":"Archard","journal-title":"Wear Control Handbook"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.protcy.2015.02.025"},{"issue":"2","key":"ref11","first-page":"264","article-title":"Analytical model of mechanism moving reliability taking account of kinematics joint gap","volume":"29","author":"Huang","year":"2007","journal-title":"J. Mech. Strength"},{"issue":"5","key":"ref12","first-page":"679","article-title":"Analysis of the motion reliability based on the effective length model of continuous contact and the Archard\u2019s wear theory","volume":"32","author":"Wan","year":"2013","journal-title":"Mech. Sci. Technol."},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-84800-131-2_16"},{"key":"ref14","article-title":"Materials and Design: The Art and Science of Material Selection in Product Design","author":"Ashby","year":"2013"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1201\/9781482265873"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/j.ress.2020.107234"}],"event":{"name":"2025 9th International Conference on System Reliability and Safety (ICSRS)","location":"Turin, Italy","start":{"date-parts":[[2025,11,26]]},"end":{"date-parts":[[2025,11,28]]}},"container-title":["2025 9th International Conference on System Reliability and Safety (ICSRS)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx8\/11422028\/11422048\/11422171.pdf?arnumber=11422171","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T05:07:36Z","timestamp":1773292056000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/11422171\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,26]]},"references-count":16,"URL":"https:\/\/doi.org\/10.1109\/icsrs68021.2025.11422171","relation":{},"subject":[],"published":{"date-parts":[[2025,11,26]]}}}