{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T00:04:09Z","timestamp":1729641849754,"version":"3.28.0"},"reference-count":49,"publisher":"IEEE","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2015,11]]},"DOI":"10.1109\/iecon.2015.7392272","type":"proceedings-article","created":{"date-parts":[[2016,3,8]],"date-time":"2016-03-08T22:52:31Z","timestamp":1457477551000},"page":"001252-001257","source":"Crossref","is-referenced-by-count":3,"title":["A portable point-of-care device for multi-parametric diabetes mellitus analysis"],"prefix":"10.1109","author":[{"given":"Jaime","family":"Punter-Villagrasa","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristina","family":"Paez-Aviles","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jordi","family":"Colomer-Farrarons","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jaime","family":"Lopez-Sanchez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Esteve","family":"Juanola-Feliu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pere","family":"Miribel-Catala","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joan","family":"Cid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria","family":"Kitsara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miguel","family":"Aller-Pellitero","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Neus","family":"Sabate","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F. Javier","family":"del Campo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ivon","family":"Rodriguez-Villarreal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2013.12.025"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1002\/anie.201207239"},{"key":"ref33","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1093\/clinchem\/39.2.283","article-title":"Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer","volume":"39","author":"erickson","year":"1993","journal-title":"Clin Chern"},{"key":"ref32","first-page":"155","article-title":"Existing and Emerging Technologies for Point-of-Care Testing","volume":"35","author":"st john","year":"2014","journal-title":"Clin Biochem Rev"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"22313","DOI":"10.3390\/s141222313","article-title":"Evaluation of optical detection platforms for multiplexed detection of proteins and the need for point-of-care biosensors for clinical use","volume":"14","author":"spindel","year":"2014","journal-title":"Sensors (Basel)"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1158\/1940-6207.CAPR-14-0248"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1039\/c2lc21299d"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1021\/ac9013989"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-950X.2011.00854.x"},{"key":"ref34","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1093\/clinchem\/39.6.1069","article-title":"Analytical evaluation of i-STAT Portable Clinical Analyzer and use by nonlaboratory health-care professionals","volume":"39","author":"jacobs","year":"1993","journal-title":"Clin Chern"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1039\/C5AN00054H"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1007\/s00340-012-5080-z"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.3003981"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.atherosclerosis.2015.01.039"},{"key":"ref1","first-page":"88","article-title":"Prevalence of diabetes mellitus and impaired glucose regulation in Spain: the Dibet.es Study","volume":"55","author":"soriguer","year":"2011"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2011.11.031"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1172\/JCI76666"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.5617\/jeb.238"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1039\/C4LC00669K"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1002\/biot.201200386"},{"key":"ref26","first-page":"933209","article-title":"Ex-vivo glucose sensors using micro-dialysis: importance of on-line recovery rate determination by multi-analyte infrared spectrometry","author":"vahlsing","year":"2015","journal-title":"Proc SPIE 9332 Optical Diagnostics and Sensing XV Toward Point-of-Care Diagnostics"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1021\/ac2030199"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1111\/j.1749-6632.1962.tb13623.x"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"1596","DOI":"10.1093\/clinchem\/45.9.1596","article-title":"In Vitro Diagnostics in Diabetes: Meeting the Challenge","volume":"45","author":"turner","year":"1999","journal-title":"Clin Chem"},{"journal-title":"Blood glucose monitoring test systems for prescription point-of-care use FDA draft guidance","year":"2014","key":"ref40"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/0265-928X(89)80026-4"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/0956-5663(91)85005-H"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.2337\/diab.23.5.397"},{"key":"ref15","first-page":"594","article-title":"Getting under the skin: Implantable Glucose Sensors","volume":"70","author":"celia","year":"2011","journal-title":"Anal Chem"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/MIM.2012.6145254"},{"article-title":"European Diabetes Diagnostic Market: Growing Diabetes Prevalence Drives Demand","year":"2012","author":"sashidar","key":"ref17"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.3390\/s150204564"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2012.09.033"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1111\/j.1523-1755.2005.00226.x"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1681\/ASN.2005030226"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2013.10.075"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.tibtech.2014.01.003"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1177\/193229681200600228"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2011.6090122"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2014.2364139"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"4558","DOI":"10.3390\/s100504558","article-title":"Glucose biosensors: an overview of use in clinical practice","volume":"10","author":"yoo","year":"2010","journal-title":"Sensors (Basel)"},{"key":"ref46","article-title":"Small-volume multiparametric electrochemical detection at low cost polymeric devices featuring nanoelectrodes","author":"kitsara","year":"0","journal-title":"Proc SPIE 9518 Bio-MEMS and Medical Microdevices II"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2013.12.016"},{"key":"ref48","doi-asserted-by":"publisher","DOI":"10.1039\/c2lc40946a"},{"key":"ref47","article-title":"Bioelectronics for Amperometric Biosensors","author":"punter-villagrasa","year":"0","journal-title":"State of the Art in Biosensors - General Aspects"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1016\/j.snb.2007.07.021"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/23\/3\/033001"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1016\/S0013-4686(97)00171-0"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1016\/j.aca.2010.08.001"}],"event":{"name":"IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society","start":{"date-parts":[[2015,11,9]]},"location":"Yokohama","end":{"date-parts":[[2015,11,12]]}},"container-title":["IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/7378180\/7392066\/07392272.pdf?arnumber=7392272","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,9,16]],"date-time":"2020-09-16T21:43:23Z","timestamp":1600292603000},"score":1,"resource":{"primary":{"URL":"http:\/\/ieeexplore.ieee.org\/document\/7392272\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11]]},"references-count":49,"URL":"https:\/\/doi.org\/10.1109\/iecon.2015.7392272","relation":{},"subject":[],"published":{"date-parts":[[2015,11]]}}}