{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,13]],"date-time":"2025-02-13T05:09:51Z","timestamp":1739423391531,"version":"3.37.0"},"reference-count":19,"publisher":"IEEE","license":[{"start":{"date-parts":[[2024,10,14]],"date-time":"2024-10-14T00:00:00Z","timestamp":1728864000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,10,14]],"date-time":"2024-10-14T00:00:00Z","timestamp":1728864000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,10,14]]},"DOI":"10.1109\/isgteurope62998.2024.10863700","type":"proceedings-article","created":{"date-parts":[[2025,2,11]],"date-time":"2025-02-11T18:19:23Z","timestamp":1739297963000},"page":"1-6","source":"Crossref","is-referenced-by-count":0,"title":["Power transformers winding deformation diagnostic using a fast and affordable method for measuring leakage inductance"],"prefix":"10.1109","author":[{"given":"Vladimir","family":"Valenti\u0107","sequence":"first","affiliation":[{"name":"Croatian Transmission System Operator Ltd.,Rijeka,Croatia"}]},{"given":"Tomislav","family":"Plav\u0161i\u0107","sequence":"additional","affiliation":[{"name":"Croatian Transmission System Operator Ltd.,Zagreb,Croatia"}]},{"given":"Ivica","family":"Petrovi\u0107","sequence":"additional","affiliation":[{"name":"Croatian Transmission System Operator Ltd.,Osijek,Croatia"}]},{"given":"Robert","family":"Noskov","sequence":"additional","affiliation":[{"name":"Croatian Transmission System Operator Ltd.,Osijek,Croatia"}]}],"member":"263","reference":[{"issue":"179","key":"ref1","first-page":"768","volume":"i","author":"Lech","year":"1968","journal-title":"Detecting transformer winding damage\u2014the low voltage impulse method"},{"key":"ref2","first-page":"paper 12-05","article-title":"Short-circuit testing of power transformers and the detection and location of damage","author":"Waters","year":"1968","journal-title":"CIGRE Session (Paris)"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1109\/TPAS.1972.293487"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1109\/TPAS.1973.293659"},{"key":"ref5","first-page":"paper 12-01","article-title":"Insulation diagnostic system for HV power transformer insulation","author":"Malewski","year":"1986","journal-title":"CIGRE Session (Paris)"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/61.368384"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/TPAS.1978.354718"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/61.4283"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1109\/61.796226"},{"key":"ref10","first-page":"37","article-title":"Diagnostic of power transformers by using the transfer function method ISH\u201999","volume-title":"11th Int. Symp. on High Voltage Engineering (London, 1999)","volume":"1","author":"Christian"},{"issue":"347","key":"ref11","first-page":"1","article-title":"Samimi, M.H.;Siegel, M. Diagnostic Measurements for Power Transformers","volume":"9","author":"Tenbohlen","year":"2016","journal-title":"Energies"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2013.2289944"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/ISIE.2007.4374785"},{"article-title":"Detection of Transformer Windings Failures With Frequency Response Analysis Method Obtained With Different Signals","volume-title":"Conference: 9th International Scientific Symposium on Electrical Power Engineering","author":"Kuniewski","key":"ref14"},{"issue":"1","key":"ref15","first-page":"8","article-title":"Finite-Impulse-Response Modeling of Voltage Instrument Transformers Applicable for Fast Front Transients Simulations","volume":"67","author":"Dadi\u0107","year":"2018","journal-title":"Journal of Energy"},{"key":"ref16","first-page":"A2","article-title":"Prikaz metode analize frekvencijskog odziva transformatora i prva iskustva","volume-title":"8. savjetovanje HRO CIGR\u00c9","author":"Hutter","year":"2007"},{"key":"ref17","article-title":"Enhanced Diagnosis of Power Transformers using On- and Off-line Methods: Results, Examples and Future Trends","volume-title":"CIGR\u00c9, Session","author":"Tenbohlen","year":"2000"},{"issue":"2007","key":"ref18","first-page":"584","article-title":"The Numerical Calculation of Low Frequency Electro-Magnetic Transient Phenomena in Power Transformers","volume":"56","author":"Toki\u0107","year":"2007","journal-title":"Journal of Energy"},{"issue":"1-4","key":"ref19","first-page":"40","article-title":"Calculation of voltage distribution along the transformer winding using the wide band transformer model","volume":"66","author":"Juri\u0161i\u0107","year":"2007","journal-title":"Journal of Energy"}],"event":{"name":"2024 IEEE PES Innovative Smart Grid Technologies Europe (ISGT EUROPE)","start":{"date-parts":[[2024,10,14]]},"location":"Dubrovnik, Croatia","end":{"date-parts":[[2024,10,17]]}},"container-title":["2024 IEEE PES Innovative Smart Grid Technologies Europe (ISGT EUROPE)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx8\/10861900\/10861888\/10863700.pdf?arnumber=10863700","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,12]],"date-time":"2025-02-12T06:40:32Z","timestamp":1739342432000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10863700\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,14]]},"references-count":19,"URL":"https:\/\/doi.org\/10.1109\/isgteurope62998.2024.10863700","relation":{},"subject":[],"published":{"date-parts":[[2024,10,14]]}}}