{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,24]],"date-time":"2025-03-24T07:38:37Z","timestamp":1742801917335,"version":"3.28.0"},"reference-count":30,"publisher":"IEEE","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2015,6]]},"DOI":"10.1109\/isie.2015.7281580","type":"proceedings-article","created":{"date-parts":[[2015,10,1]],"date-time":"2015-10-01T21:54:18Z","timestamp":1443736458000},"page":"843-848","source":"Crossref","is-referenced-by-count":11,"title":["Induction machine bearing faults detection based on Hilbert-Huang transform"],"prefix":"10.1109","author":[{"given":"Elhoussin","family":"Elbouchikhi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vincent","family":"Choqueuse","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Youness","family":"Trachi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed","family":"Benbouzid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"doi-asserted-by":"publisher","key":"ref30","DOI":"10.1109\/78.782222"},{"key":"ref10","first-page":"247","article-title":"Rotor cage faults detection in induction motors by motor current demodulation analysis","author":"jaksch","year":"2005","journal-title":"in Proceedings of the 2005 SDEMPED Cracow Poland"},{"doi-asserted-by":"publisher","key":"ref11","DOI":"10.1109\/TIE.2009.2026211"},{"doi-asserted-by":"publisher","key":"ref12","DOI":"10.1109\/TEC.2008.2003207"},{"doi-asserted-by":"publisher","key":"ref13","DOI":"10.1109\/TEC.2013.2279917"},{"doi-asserted-by":"publisher","key":"ref14","DOI":"10.1109\/61.216849"},{"doi-asserted-by":"publisher","key":"ref15","DOI":"10.1109\/61.568235"},{"key":"ref16","first-page":"1","article-title":"Demodulation analysis for exact rotor faults detection under changing parameters","author":"jaksch","year":"2009","journal-title":"SDEMPED"},{"doi-asserted-by":"publisher","key":"ref17","DOI":"10.1016\/j.ymssp.2009.05.015"},{"doi-asserted-by":"publisher","key":"ref18","DOI":"10.1109\/TSP.2014.2333565"},{"key":"ref19","first-page":"1249","article-title":"Hilbert transform-based bearing failure detection in dfig-based wind turbines","volume":"6","author":"amirat","year":"2011","journal-title":"International Review of Electrical Engineering"},{"doi-asserted-by":"publisher","key":"ref28","DOI":"10.1109\/78.558469"},{"doi-asserted-by":"publisher","key":"ref4","DOI":"10.1109\/TIE.2008.2007527"},{"year":"1995","author":"schwartz","journal-title":"Communication Systems and Techniques New York 1995","key":"ref27"},{"doi-asserted-by":"publisher","key":"ref3","DOI":"10.1109\/TIE.2011.2160138"},{"doi-asserted-by":"publisher","key":"ref6","DOI":"10.1109\/TIA.2009.2031888"},{"year":"1991","author":"boashash","journal-title":"Time-Frequency signal analysis in advances in Spectrum Estimation S Haykin Ed","key":"ref29"},{"doi-asserted-by":"publisher","key":"ref5","DOI":"10.1109\/41.873206"},{"key":"ref8","first-page":"3584","article-title":"A comparative study of time-frequency representations for fault detection in wind turbine","author":"elbouchikhi","year":"2011","journal-title":"Proceedings of the 2011 IEEE IECON Melbourne (Australia)"},{"year":"1997","author":"stoica","journal-title":"Introduction to Spectral Analysis","key":"ref7"},{"doi-asserted-by":"publisher","key":"ref2","DOI":"10.1109\/TNNLS.2011.2178443"},{"key":"ref9","first-page":"176","article-title":"Stator current demodulation for induction machine rotor faults diagnosis","author":"elbouchikhi","year":"2014","journal-title":"Proceedings of the 2014 IEEE ICGE Sfax Tunisia IEEE"},{"year":"2006","author":"blolt","journal-title":"Condition monitoring of mechanical faults in variable speed induction motor drives applications of stator current time-frequency analysis and parameter estimation","key":"ref1"},{"doi-asserted-by":"publisher","key":"ref20","DOI":"10.1016\/j.ymssp.2013.06.012"},{"doi-asserted-by":"publisher","key":"ref22","DOI":"10.1109\/TIA.2009.2027558"},{"doi-asserted-by":"publisher","key":"ref21","DOI":"10.1109\/TIE.2008.2011580"},{"doi-asserted-by":"publisher","key":"ref24","DOI":"10.1098\/rspa.1998.0193"},{"doi-asserted-by":"publisher","key":"ref23","DOI":"10.1109\/TII.2013.2289941"},{"year":"1996","author":"hahn","journal-title":"Hilbert Transforms in Signal Processing","key":"ref26"},{"key":"ref25","article-title":"On empirical mode decomposition and its algorithms","author":"rilling","year":"2003","journal-title":"IEEE-EURASIP Workshop on Nonlinear Signal and Image Processing"}],"event":{"name":"2015 IEEE 24th International Symposium on Industrial Electronics (ISIE)","start":{"date-parts":[[2015,6,3]]},"location":"Buzios, Rio de Janeiro, Brazil","end":{"date-parts":[[2015,6,5]]}},"container-title":["2015 IEEE 24th International Symposium on Industrial Electronics (ISIE)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/7268961\/7281431\/07281580.pdf?arnumber=7281580","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,3,24]],"date-time":"2017-03-24T20:39:42Z","timestamp":1490387982000},"score":1,"resource":{"primary":{"URL":"http:\/\/ieeexplore.ieee.org\/document\/7281580\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,6]]},"references-count":30,"URL":"https:\/\/doi.org\/10.1109\/isie.2015.7281580","relation":{},"subject":[],"published":{"date-parts":[[2015,6]]}}}