{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,5]],"date-time":"2026-03-05T12:57:08Z","timestamp":1772715428125,"version":"3.50.1"},"reference-count":39,"publisher":"IEEE","license":[{"start":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T00:00:00Z","timestamp":1747180800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T00:00:00Z","timestamp":1747180800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R01 EB036341"],"award-info":[{"award-number":["R01 EB036341"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007880","name":"Johns Hopkins University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007880","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,5,14]]},"DOI":"10.1109\/ismr67322.2025.11025971","type":"proceedings-article","created":{"date-parts":[[2025,6,13]],"date-time":"2025-06-13T17:47:42Z","timestamp":1749836862000},"page":"164-171","source":"Crossref","is-referenced-by-count":1,"title":["Cannula-Mounted Robots for Semi-Autonomous Vertebroplasty: A Comparison of Piezo-Based and Screw-Based Inchworm Drive Designs"],"prefix":"10.1109","author":[{"given":"Michelle J.","family":"Song","sequence":"first","affiliation":[{"name":"Johns Hopkins University,Department of Mechanical Engineering,Baltimore,MD,USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benjamin D.","family":"Killeen","sequence":"additional","affiliation":[{"name":"Johns Hopkins University,Department of Computer Science,Baltimore,MD,USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Justin D.","family":"Opfermann","sequence":"additional","affiliation":[{"name":"Johns Hopkins University,Department of Mechanical Engineering,Baltimore,MD,USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Blanca","family":"Inigo","sequence":"additional","affiliation":[{"name":"Johns Hopkins University,Department of Computer Science,Baltimore,MD,USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher","family":"Bailey","sequence":"additional","affiliation":[{"name":"Johns Hopkins University,Department of Radiology,Baltimore,MD,USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali","family":"Uneri","sequence":"additional","affiliation":[{"name":"Johns Hopkins University,Department of Biomedical Engineering,Baltimore,MD,USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mathias","family":"Unberath","sequence":"additional","affiliation":[{"name":"Johns Hopkins University,Department of Computer Science,Baltimore,MD,USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Axel","family":"Krieger","sequence":"additional","affiliation":[{"name":"Johns Hopkins University,Department of Mechanical Engineering,Baltimore,MD,USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1007\/s00198-006-0172-4"},{"key":"ref2","doi-asserted-by":"crossref","DOI":"10.1227\/NEU.0000000000000947","article-title":"Management of the Elderly With Vertebral Compression Fractures","volume":"77","author":"Goldstein","year":"2015","journal-title":"Neurosurgery"},{"issue":"1","key":"ref3","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1038\/s41598-023-50145-w","article-title":"Prevalence, incidence of and risk factors for vertebral fracture in the community: the Vietnam Osteoporosis Study","volume":"14","author":"Nguyen","year":"2024","journal-title":"Scientific Reports"},{"issue":"5","key":"ref4","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1016\/j.spinee.2021.12.007","article-title":"Global incidence, prevalence, and disability of vertebral fractures: a systematic analysis of the global burden of disease study 2019","volume":"22","author":"Dong","year":"2022","journal-title":"The Spine Journal"},{"issue":"4","key":"ref5","doi-asserted-by":"crossref","first-page":"46","DOI":"10.7812\/TPP\/12-037","article-title":"Evaluation and Management of Vertebral Compression Fractures","volume":"16","author":"Alexandru","year":"2012","journal-title":"The Permanente Journal"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-022-03147-9"},{"issue":"7","key":"ref7","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.amjmed.2022.02.035","article-title":"Diagnosis and Management of Vertebral Compression Fracture","volume":"135","author":"Alsoof","year":"2022","journal-title":"The American Journal of Medicine"},{"key":"ref8","article-title":"Percutaneous Vertebroplasty and Kyphoplasty","volume-title":"StatPearls","author":"Patel","year":"2024"},{"issue":"2","key":"ref9","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.afos.2017.06.002","article-title":"Surgical techniques and clinical evidence of vertebroplasty and kyphoplasty for osteoporotic vertebral fractures","volume":"3","author":"Lee","year":"2017","journal-title":"Osteoporosis and Sarcopenia"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(10)60954-3"},{"issue":"10","key":"ref11","doi-asserted-by":"crossref","first-page":"1548","DOI":"10.1016\/j.jvir.2010.06.015","article-title":"The Safety and Effectiveness of a Curved Needle for Vertebral Augmentation: Comparison with Traditional Techniques","volume":"21","author":"Saxena","year":"2010","journal-title":"Journal of Vascular and Interventional Radiology"},{"key":"ref12","doi-asserted-by":"crossref","DOI":"10.3171\/2020.9.SPINE201525","article-title":"Comparison of operator and patient radiation exposure during fluoroscopy-guided vertebroplasty and kyphoplasty: a systematic review and meta-analysis","author":"Kopparapu","year":"2021","journal-title":"section: Journal of Neurosurgery: Spine"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1007\/s00701-011-1239-3"},{"issue":"9","key":"ref14","doi-asserted-by":"crossref","first-page":"1536","DOI":"10.3390\/medicina59091536","article-title":"Complications of Percutaneous Vertebroplasty: A Pictorial Review","volume":"59","author":"Cavka","year":"2023","journal-title":"Medicina"},{"issue":"5","key":"ref15","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.3390\/jcm13051495","article-title":"Efficacy and Complication Rates of Percutaneous Vertebroplasty and Kyphoplasty in the Treatment of Vertebral Compression Fractures: A Retrospective Analysis of 280 Patients","volume":"13","author":"Cerny","year":"2024","journal-title":"Journal of Clinical Medicine"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1007\/s11604-022-01322-w"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2020-016733"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"101721","DOI":"10.1016\/j.inat.2023.101721","article-title":"Evolution of robotics in spine surgery: A historical perspective","volume":"33","author":"Gajjar","year":"2023","journal-title":"Interdisciplinary Neurosurgery"},{"key":"ref19","doi-asserted-by":"crossref","DOI":"10.1109\/BIBE52308.2021.9635356","article-title":"Feasibility of a Cannula-Mounted Piezo Robot for Image-Guided Vertebral Augmentation: Toward a Low Cost, Semi-Autonomous Approach","volume-title":"BIBE 2021\u201321st IEEE International Conference on BioInformatics and BioEngineering, Proceedings. Institute of Electrical and Electronics Engineers Inc.","author":"Opfermann","year":"2021"},{"issue":"5","key":"ref20","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1049\/htl.2018.5066","article-title":"Augmented reality-based feedback for technician-in-the-loop C-arm repositioning","volume":"5","author":"Unberath","year":"2018","journal-title":"Healthcare Technology Letters"},{"issue":"2","key":"ref21","first-page":"2722","article-title":"Reflective-AR Display: An Interaction Methodology for Virtual-to-Real Alignment in Medical Robotics","volume-title":"IEEE Robotics and Automation Letters","volume":"5","author":"Fotouhi","year":"2020"},{"issue":"2","key":"ref22","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1109\/TMI.2020.3037013","article-title":"Development and Pre-Clinical Analysis of Spatiotemporal-Aware Augmented Reality in Orthopedic Interventions","volume":"40","author":"Fotouhi","year":"2021","journal-title":"IEEE transactions on medical imaging"},{"key":"ref23","volume-title":"Micromate: Your robotic assistant for all needle interventions from head to toe","year":"2023"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1007\/11566489_14"},{"key":"ref25","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.wneu.2021.10.066","article-title":"Clinical and Radiologic Outcomes of RobotAssisted Kyphoplasty versus Fluoroscopy-Assisted Kyphoplasty in the Treatment of Osteoporotic Vertebral Compression Fractures: A Retrospective Comparative Study","volume":"158","author":"Jin","year":"2022","journal-title":"World Neurosurgery"},{"key":"ref26","first-page":"196","article-title":"Design of A Novel Hybrid Robot for Percutaneous Vertebroplasty","volume-title":"2019 4th International Conference on Robotics and Automation Engineering (ICRAE)","author":"Cheng","year":"2019"},{"key":"ref27","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1109\/RAMECH.2008.4681395","article-title":"A Robot-Assisted System for Minimally Invasive Spine Surgery of Percutaneous Vertebroplasty Based on CT Images","volume-title":"2008 IEEE Conference on Robotics, Automation and Mechatronics","author":"Ju","year":"2008"},{"key":"ref28","first-page":"1","article-title":"Positioning Accuracy of a Medical Robotic System for Spine Surgery","volume-title":"2009 2nd International Conference on Biomedical Engineering and Informatics","author":"Song","year":"2009"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1177\/21925682221096625"},{"key":"ref30","doi-asserted-by":"crossref","first-page":"4391","DOI":"10.1109\/EMBC48229.2022.9871709","article-title":"Development of Needle Guide Unit Considering Buckling Bone-Perforation Control Strategy Based on Computed TomographyGuided Needle Insertion Robot","volume-title":"2022 44th Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)","author":"Takahashi","year":"2022"},{"issue":"4","key":"ref31","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1016\/j.jvir.2009.01.008","article-title":"A Unilateral Vertebroplasty Approach Using a Curved Injection Cannula for Directed, Site-specific Vertebral Body Filling","volume":"20","author":"Hunt","year":"2009","journal-title":"Journal of Vascular and Interventional Radiology"},{"issue":"2","key":"ref32","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.jmbbm.2007.06.004","article-title":"Bone material properties and fracture analysis: Needle insertion for spinal surgery","volume":"1","author":"Teoh","year":"2008","journal-title":"Journal of the Mechanical Behavior of Biomedical Materials"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.08.1503"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1088\/2516-1091\/acd28b"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-030-00937-3_12"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-019-02011-2"},{"key":"ref37","article-title":"FluoroSAM: A Languagealigned Foundation Model for X-ray Image Segmentation","author":"Killeen","year":"2024","journal-title":"arXiv"},{"key":"ref38","volume-title":"Thorlabs - PK2FVF1 Amplified Piezoelectric Actuator with Flexure Mount, 75 V, 420 \u03bcm Max Displacement"},{"key":"ref39","article-title":"Sterilization for Medical Devices","volume-title":"FDA","year":"2024"}],"event":{"name":"2025 International Symposium on Medical Robotics (ISMR)","location":"Atlanta, GA, USA","start":{"date-parts":[[2025,5,14]]},"end":{"date-parts":[[2025,5,16]]}},"container-title":["2025 International Symposium on Medical Robotics (ISMR)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx8\/11025555\/11025956\/11025971.pdf?arnumber=11025971","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T05:06:55Z","timestamp":1749877615000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/11025971\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,14]]},"references-count":39,"URL":"https:\/\/doi.org\/10.1109\/ismr67322.2025.11025971","relation":{},"subject":[],"published":{"date-parts":[[2025,5,14]]}}}