{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T10:12:54Z","timestamp":1760609574723},"reference-count":79,"publisher":"IEEE","license":[{"start":{"date-parts":[[2023,11,28]],"date-time":"2023-11-28T00:00:00Z","timestamp":1701129600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2023,11,28]],"date-time":"2023-11-28T00:00:00Z","timestamp":1701129600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,11,28]]},"DOI":"10.1109\/ispec58282.2023.10403021","type":"proceedings-article","created":{"date-parts":[[2024,1,25]],"date-time":"2024-01-25T18:26:03Z","timestamp":1706207163000},"page":"1-13","source":"Crossref","is-referenced-by-count":1,"title":["Review of Insulator Wet Flashover Modelling and Factors Affecting Characteristics"],"prefix":"10.1109","volume":"30","author":[{"given":"Chuanbang","family":"Xia","sequence":"first","affiliation":[{"name":"State Grid Zhejiang Electric Power Co., Ltd. Wenzhou Power Supply Company"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Furong","family":"Pan","sequence":"additional","affiliation":[{"name":"State Grid Zhejiang Electric Power Co., Ltd. Wenzhou Power Supply Company"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qin","family":"Hu","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station of Chongqing University,Chongqing,China,400044"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dunhua","family":"Long","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station of Chongqing University,Chongqing,China,400044"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenqi","family":"Rong","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station of Chongqing University,Chongqing,China,400044"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanan","family":"Wei","sequence":"additional","affiliation":[{"name":"State Grid Zhejiang Electric Power Co., Ltd. Wenzhou Power Supply Company"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhenyu","family":"Zhou","sequence":"additional","affiliation":[{"name":"State Grid Zhejiang Electric Power Co., Ltd. Wenzhou Power Supply Company"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1109\/ELINSL.2008.4570283"},{"volume-title":"Water drops dynamic deformation on composite post insulators shed edge under different shed parameters and influence on the electric field between sheds","year":"2022","author":"Shang","key":"ref2"},{"issue":"1","key":"ref3","first-page":"52","article-title":"Focus on the design of polluted external insulation for ultra-high voltage substation equipment","author":"Su","year":"2001","journal-title":"Electric Power"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1109\/61.19258"},{"issue":"4","key":"ref5","first-page":"184","article-title":"Impulse flashover characteristics of hollow composite insulators with different installation angles under heavy rainfall","author":"Liu","year":"2021","journal-title":"Insul. Surge Arresters"},{"issue":"2","key":"ref6","first-page":"63","article-title":"The influence of rain on the external insulation performance","author":"Zhang","year":"1998","journal-title":"High Voltage Eng"},{"article-title":"The performance of station post insulators for UHVDC applications","year":"1997","author":"Wu","key":"ref7"},{"issue":"6","key":"ref8","first-page":"5","article-title":"Preventive treatment and analysis of the flashover on porcelain bushing of 500 kV substation equipment in rain","author":"Xu","year":"1996","journal-title":"Power System Tech"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1109\/94.740762"},{"issue":"21","key":"ref10","first-page":"1","article-title":"Research on profiles of HVDC post insulator and bushing","volume-title":"Proceedings of the CSEE","author":"Fan"},{"issue":"1","key":"ref11","first-page":"14","article-title":"Wet flashover characteristic of composite post insulators at high altitudes","volume-title":"Proceedings of the CSEE","volume":"30","author":"Zhang"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2020.3042245"},{"issue":"6","key":"ref13","first-page":"820","article-title":"Improvement of dry flashover voltage and wet flashover voltage of line insulators with accessories system","volume":"47","author":"Deng","year":"2014","journal-title":"Eng. J. Wuhan Univ"},{"issue":"6","key":"ref14","first-page":"155","article-title":"Experimental study on silicone rubber accessories to improve external insulation properties of porcelain post insulators","author":"Sun","year":"2018","journal-title":"Insul. Surge Arresters"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/ICHVE.2010.5640720"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/TDC.2018.8440283"},{"issue":"8","key":"ref17","first-page":"7","article-title":"Study on the water? cut shed\u2019s influence on the electric field of composite post insulators under wet condition","volume":"54","author":"Tan","year":"2018","journal-title":"High Voltage Appar"},{"issue":"12","key":"ref18","first-page":"2980","article-title":"Test research on heavy rain flashover performance improvement of outdoor insulation in EHV\/UHV substation","volume":"39","author":"Yu","year":"2013","journal-title":"High Voltage Eng"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2020.3012978"},{"issue":"10","key":"ref20","first-page":"93","article-title":"DC pollution flashover performance of ultra high voltage convert stations large-Size composite post insulators at high altitude areas","volume":"31","author":"Gu","year":"2016","journal-title":"Transactions of China Electrotechnical Society"},{"issue":"8","key":"ref21","first-page":"2872","article-title":"External insulation characteristics and anti-ice umbrella application of HV composite post insulators","volume":"46","author":"Liu","year":"2020","journal-title":"High Voltage Eng"},{"issue":"6","key":"ref22","first-page":"22","article-title":"Effect of booster shed arrangement on the electrical property of post insulator","author":"Li","year":"2015","journal-title":"Insul. Surge Arresters"},{"issue":"4","key":"ref23","first-page":"17","article-title":"Effect of booster shed location on the insulation performance of post insulator","author":"Wang","year":"2016","journal-title":"Insul. Surge Arresters"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1088\/1757-899X\/394\/4\/042083"},{"issue":"22","key":"ref25","first-page":"183","article-title":"Optimization of shed parameters of polluted DC post composite insulators based on finite element method","volume-title":"Proceedings of the CSEE","volume":"33","author":"Hao"},{"issue":"5","key":"ref26","first-page":"37","article-title":"Optimization and simulation of shed parameters of transformer bushing under rain conditions","volume":"12","author":"Yao","year":"2018","journal-title":"Southern Power System Tech"},{"issue":"1","key":"ref27","first-page":"23","article-title":"The experiment on auxiliary bushing shed against rain flashover of 500 kV transformers","volume":"6","author":"Chen","year":"2012","journal-title":"Southern Power System Tech"},{"issue":"6","key":"ref28","first-page":"16","article-title":"Analysis and prevention treatment for rain flashover accident of \u00b1500 kV composite bushing","author":"Shen","year":"2015","journal-title":"Insul. Surge Arresters"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/TPAS.1982.317255"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1109\/61.85878"},{"issue":"4","key":"ref31","first-page":"7","article-title":"Study of influencing factors on polluted RTV coatings hydrophobicity migration","volume":"47","author":"Xu","year":"2011","journal-title":"High Voltage Appar"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1109\/TPS.2006.876498"},{"issue":"6","key":"ref33","first-page":"1352","article-title":"Research of adhesion force between dust particles and insulator surface using atomic force mircoscope","volume":"39","author":"Wang Li Yan","year":"2013","journal-title":"High Voltage Eng"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1109\/ISEIM.2011.6826314"},{"issue":"11","key":"ref35","first-page":"14","article-title":"Preparation and anti-moisture flash performance of epoxy resin\/nano-SiO_2 composite superhydrophobic surface","volume":"50","author":"Zhao","year":"2017","journal-title":"Insul. Mater"},{"issue":"5","key":"ref36","first-page":"49","article-title":"Preparation and wet flashover characteristics of silicone superhydrophobic coating","volume":"56","author":"Su","year":"2023","journal-title":"Insul. Mater"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1109\/TDEI.2023.3322121"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1016\/j.cej.2022.138679"},{"issue":"2","key":"ref39","first-page":"673","article-title":"Experimental research on external insulation performance of semiconductive anti-Icing coated insulators with switch-off effect","volume":"42","author":"Zhou","year":"2018","journal-title":"Power System Tech"},{"author":"Farhang","key":"ref40","article-title":"Effects of the Filler Type and Quantity on the Flashover Voltage and Hydrophobicity of RTV Silicone Rubber Coatings"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1016\/j.jestch.2019.06.002"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1111\/j.1744-7402.2009.02395.x"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1016\/j.cej.2020.126476"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1109\/CATCON.2017.8280256"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1109\/TDEI.2014.004227"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2016.04.025"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.1109\/ICEMPE51623.2021.9509057"},{"key":"ref48","doi-asserted-by":"publisher","DOI":"10.1088\/0022-3727\/37\/16\/007"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.1088\/1009-0630\/9\/5\/14"},{"key":"ref50","doi-asserted-by":"publisher","DOI":"10.1116\/1.5030718"},{"key":"ref51","doi-asserted-by":"publisher","DOI":"10.1140\/epjd\/s10053-022-00417-3"},{"key":"ref52","doi-asserted-by":"publisher","DOI":"10.1088\/2058-6272\/acd83b"},{"key":"ref53","article-title":"Insulators and external insulation of power transmission and transformation equipment","author":"Guan","year":"2006","journal-title":"Tsinghua University Press"},{"issue":"6","key":"ref54","first-page":"1703","article-title":"Cleaning effect of rainfall on surface contamination of insulators","volume":"39","author":"Wang","year":"2015","journal-title":"Power System Tech"},{"key":"ref55","doi-asserted-by":"publisher","DOI":"10.1109\/ICPADM.2000.875711"},{"issue":"10","key":"ref56","first-page":"2568","article-title":"Pollution flashover performance of converter station post insulator at high altitude area","volume":"38","author":"Zhang","year":"2012","journal-title":"High Voltage Eng"},{"volume-title":"Study on AC flashover performance and flashover model of insulator strings under heavy rainstorms","year":"2013","author":"Zhou","key":"ref57"},{"issue":"2","key":"ref58","first-page":"525","article-title":"Lightning impulse arc development process and flashover characteristics of 110 kV SIR insulators under heavy rainstorms","volume":"49","author":"Dong","year":"2023","journal-title":"High Voltage Eng"},{"issue":"6","key":"ref59","first-page":"216","article-title":"Influence of heavy rainfall on switching impulse flashover characteristics of composite hollow insulator","author":"Liu","year":"2017","journal-title":"Insul. Surge Arresters"},{"key":"ref60","doi-asserted-by":"publisher","DOI":"10.1109\/POWERCON.2018.8601963"},{"key":"ref61","doi-asserted-by":"publisher","DOI":"10.1049\/piee.1975.0124"},{"key":"ref62","doi-asserted-by":"publisher","DOI":"10.1109\/tce.1958.6372812"},{"key":"ref63","doi-asserted-by":"publisher","DOI":"10.1109\/61.103674"},{"issue":"1","key":"ref64","first-page":"45","article-title":"Influence of rainwater resistivity on power frequency wet lightning voltage","author":"Zhao","year":"1985","journal-title":"High Voltage Appar"},{"issue":"2","key":"ref65","first-page":"42","article-title":"Influence of rainwater temperature on power frequency wet lightning voltage","author":"Long","year":"1984","journal-title":"High Voltage Appar"},{"issue":"3","key":"ref66","first-page":"22","article-title":"High-voltage DC wall bushing nonuniform rain flashover and its protective measures","author":"Sun","year":"1993","journal-title":"Power System Tech"},{"issue":"4","key":"ref67","first-page":"56","article-title":"Finite element analysis of the effect of covered water conductivity on the ground insulator icing flashover","volume":"29","author":"Lei","year":"2015","journal-title":"J. Hunan Univ. Technology"},{"issue":"9","key":"ref68","first-page":"2278","article-title":"Influence of separated globules on post insulator electric field distribution","volume":"36","author":"Xu","year":"2010","journal-title":"High Voltage Eng"},{"issue":"17","key":"ref69","first-page":"148","article-title":"Study on electric field distribution and flashover characteristics of water droplets on the surface of silicone rubber","author":"Xiang","year":"2020","journal-title":"Electrical Eng"},{"issue":"9","key":"ref70","first-page":"69","article-title":"Study on discharge of separation water droplets under DC field","volume":"47","author":"Zhang","year":"2011","journal-title":"High Voltage Appar"},{"issue":"4","key":"ref71","first-page":"1017","article-title":"Morphologic characteristics of water droplets on composite insulator surface and their effects on flashover voltage","volume":"40","author":"Liu","year":"2014","journal-title":"High Voltage Eng"},{"issue":"2","key":"ref72","first-page":"135","article-title":"Influence of distribution of raindrops on electric field of insulator surface based on ANSYS","volume":"52","author":"Wang","year":"2016","journal-title":"High Voltage Appar"},{"issue":"6","key":"ref73","first-page":"171","article-title":"Dry and wet flashover characteristics analysis of silicone rubber composite insulators on the roof of EMU","volume":"58","author":"Ma","year":"2022","journal-title":"High Voltage Appar"},{"issue":"11","key":"ref74","first-page":"6","article-title":"Research on spatial electric field distribution of rod-plate electrode in rain environment","author":"Xiang","year":"2020","journal-title":"Electrical Eng"},{"issue":"2","key":"ref75","first-page":"151","article-title":"Study on space electric field distribution of rod-plate electrodes in rain environment","volume":"24","author":"Cao","year":"2020","journal-title":"Journal of Electrical Machinery and Control"},{"key":"ref76","doi-asserted-by":"publisher","DOI":"10.1049\/hve2.12082"},{"key":"ref77","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2020.3004878"},{"key":"ref78","doi-asserted-by":"publisher","DOI":"10.1049\/hve2.12133"},{"key":"ref79","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2021.107659"}],"event":{"name":"2023 IEEE Sustainable Power and Energy Conference (iSPEC)","start":{"date-parts":[[2023,11,28]]},"location":"Chongqing, China","end":{"date-parts":[[2023,11,30]]}},"container-title":["2023 IEEE Sustainable Power and Energy Conference (iSPEC)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/10402601\/10402797\/10403021.pdf?arnumber=10403021","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,1]],"date-time":"2024-02-01T10:22:52Z","timestamp":1706782972000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10403021\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,28]]},"references-count":79,"URL":"https:\/\/doi.org\/10.1109\/ispec58282.2023.10403021","relation":{},"subject":[],"published":{"date-parts":[[2023,11,28]]}}}