{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T12:41:26Z","timestamp":1777552886191,"version":"3.51.4"},"reference-count":52,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"10","license":[{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T00:00:00Z","timestamp":1727740800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"funder":[{"name":"Schweizer Paraplegiker Stiftung"},{"name":"ETH Z&#x00FC;rich Foundation ETH-SPS Digital Transformation in Personalized Health Care for SCI"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE J. Biomed. Health Inform."],"published-print":{"date-parts":[[2024,10]]},"DOI":"10.1109\/jbhi.2024.3411693","type":"journal-article","created":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T17:26:50Z","timestamp":1718040410000},"page":"5768-5779","source":"Crossref","is-referenced-by-count":10,"title":["Robust Feature Selection for BP Estimation in Multiple Populations: Towards Cuffless Ambulatory BP Monitoring"],"prefix":"10.1109","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1556-7179","authenticated-orcid":false,"given":"Ana","family":"Cisnal","sequence":"first","affiliation":[{"name":"Spinal Cord Injury &amp; Artificial Intelligence Lab, ETH Zurich, Z&#x00FC;rich, Switzerland"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-3176-0188","authenticated-orcid":false,"given":"Yanke","family":"Li","sequence":"additional","affiliation":[{"name":"Spinal Cord Injury &amp; Artificial Intelligence Lab, ETH Zurich, Z&#x00FC;rich, Switzerland"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-5107-428X","authenticated-orcid":false,"given":"Bertram","family":"Fuchs","sequence":"additional","affiliation":[{"name":"Spinal Cord Injury &amp; Artificial Intelligence Lab, ETH Zurich, Z&#x00FC;rich, Switzerland"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1191-9042","authenticated-orcid":false,"given":"Mehdi","family":"Ejtehadi","sequence":"additional","affiliation":[{"name":"Spinal Cord Injury &amp; Artificial Intelligence Lab, ETH Zurich, Z&#x00FC;rich, Switzerland"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1726-2950","authenticated-orcid":false,"given":"Robert","family":"Riener","sequence":"additional","affiliation":[{"name":"Sensory-Motor Systems Lab, ETH Zurich, Z&#x00FC;rich, Switzerland"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6143-1432","authenticated-orcid":false,"given":"Diego","family":"Paez-Granados","sequence":"additional","affiliation":[{"name":"Spinal Cord Injury &amp; Artificial Intelligence Lab, ETH Zurich, Z&#x00FC;rich, Switzerland"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1208\/aapsj080117"},{"issue":"2","key":"ref2","first-page":"323","article-title":"Wearable cuffless blood pressure monitoring devices: A systematic review and meta-analysis","volume-title":"Eur. Heart J.-Digit. Health","volume":"3","author":"Islam","year":"2022"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/28\/3\/r01"},{"issue":"12","key":"ref4","first-page":"3299","article-title":"Nonlinear cuffless blood pressure estimation of healthy subjects using pulse transit time and arrival time","volume-title":"IEEE Trans. Instrum. Meas.","volume":"66","author":"Esmaili","year":"2017"},{"issue":"9","key":"ref5","article-title":"Improving cuff-less continuous blood pressure estimation with linear regression analysis","volume-title":"Electronics","volume":"11","author":"Figini","year":"2022"},{"issue":"3","key":"ref6","first-page":"2475","article-title":"Towards robust blood pressure estimation from pulse wave velocity measured by photoplethysmography sensors","volume-title":"IEEE Sensors J.","volume":"22","author":"Byfield","year":"2022"},{"issue":"5","key":"ref7","first-page":"2096","article-title":"Continuous PPG-Based blood pressure monitoring using multi-linear regression","volume-title":"IEEE J. Biomed. Health Inform.","volume":"26","author":"Haddad","year":"2022"},{"key":"ref8","first-page":"58146","article-title":"Cuffless blood pressure estimation using single channel photoplethysmography: A two-step method","volume-title":"IEEE Access","volume":"8","author":"Khalid","year":"2020"},{"key":"ref9","first-page":"138817","article-title":"A benchmark study of machine learning for analysis of signal feature extraction techniques for blood pressure estimation using photoplethysmography (PPG)","volume-title":"IEEE Access","volume":"9","author":"Maqsood","year":"2021"},{"issue":"19","key":"ref10","article-title":"Generalized deep neural network model for cuffless blood pressure estimation with photoplethysmogram signal only","volume-title":"Sensors","volume":"20","author":"Hsu","year":"2020"},{"issue":"3","key":"ref11","first-page":"236","article-title":"Joint regression network and window function-based piecewise neural network for cuffless continuous blood pressure estimation only using single photoplethesmogram","volume-title":"IEEE Trans. Consum. Electron.","volume":"68","author":"Qiu","year":"2022"},{"issue":"8","key":"ref12","first-page":"3708","article-title":"Multi-dimensional feature combination method for continuous blood pressure measurement based on wrist PPG sensor","volume-title":"IEEE J. Biomed. Health Inform.","volume":"26","author":"Yao","year":"2022"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1177\/000331977302400407"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1177\/0954411920921628"},{"issue":"7","key":"ref15","first-page":"2864","article-title":"A comparison of wearable tonometry, photoplethysmography, and electrocardiography for cuffless measurement of blood pressure in an ambulatory setting","volume-title":"IEEE J. Biomed. Health Inform.","volume":"26","author":"Mieloszyk","year":"2022"},{"key":"ref16","article-title":"VitalPy: A vital signal analysis python package","author":"Cisnal","year":"2023"},{"issue":"4","key":"ref17","first-page":"1018","article-title":"Estimation and validation of arterial blood pressure using photoplethysmogram morphology features in conjunction with pulse arrival time in large open databases","volume-title":"IEEE J. Biomed. Health Inform.","volume":"25","author":"Yang","year":"2021"},{"issue":"21","key":"ref18","article-title":"Blood pressure continuous measurement through a wearable device: Development and validation of a cuffless method","volume-title":"Sensors","volume":"21","author":"Marchi","year":"2021"},{"issue":"1","key":"ref19","first-page":"79","article-title":"Multi-sensor fusion approach for cuff-less blood pressure measurement","volume-title":"IEEE J. Biomed. Health Inform.","volume":"24","author":"Miao","year":"2020"},{"issue":"12","key":"ref20","article-title":"Cuffless blood pressure estimation using pressure pulse wave signals","volume-title":"Sensors","volume":"18","author":"Liu","year":"2018"},{"issue":"8","key":"ref21","first-page":"4300","article-title":"Blood pressure estimation using photoplethysmogram signal and its morphological features","volume-title":"IEEE Sensors J.","volume":"20","author":"Hasanzadeh","year":"2020"},{"issue":"10","key":"ref22","first-page":"1063","article-title":"In vivo evaluation of a novel, wrist-mounted arterial pressure sensing device versus the traditional hand-held tonometer","volume-title":"Med. Eng. Phys.","volume":"38","author":"Vardoulis","year":"2016"},{"key":"ref23","article-title":"Photoplethysmogram analysis and applications: An integrative review","volume-title":"Front. Physiol.","volume":"12","author":"Park","year":"2022"},{"issue":"5","key":"ref24","article-title":"Baseline correction using adaptive iteratively reweighted penalized least squares","volume-title":"Analyst","volume":"135","author":"Zhang","year":"2010"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1088\/0967-3334\/32\/3\/008"},{"issue":"3","key":"ref26","first-page":"832","article-title":"Signal quality indices for the electrocardiogram and photoplethysmogram: Derivation and applications to wireless monitoring","volume-title":"IEEE J. Biomed. Health Inform.","volume":"19","author":"Orphanidou","year":"2015"},{"issue":"2","key":"ref27","first-page":"154","article-title":"An innovative dicrotic notch detection algorithm which combines rule-based logic with digital signal processing techniques","volume-title":"Comput. Biomed. Res.","volume":"28","author":"Oppenheim","year":"1995"},{"issue":"09","key":"ref28","article-title":"Methods of extracting feature from photoplethysmogram waveform for non-invasive diagnostic applications","volume-title":"Int. J. Online Eng.","volume":"16","author":"Hafifah","year":"2020"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/ICECTECH.2010.5480006"},{"key":"ref30","article-title":"The assessment of autonomic nervous system activity based on photoplethysmography in healthy young men","volume-title":"Front. Physiol.","volume":"12","author":"Liu","year":"2021"},{"issue":"4","key":"ref31","first-page":"859","article-title":"Cuffless blood pressure estimation algorithms for continuous health-care monitoring","volume-title":"IEEE Trans. Biomed. Eng.","volume":"64","author":"Kachuee","year":"2017"},{"key":"ref32","first-page":"44963","article-title":"Central blood pressure estimation from distal PPG measurement using semiclassical signal analysis features","volume-title":"IEEE Access","volume":"9","author":"Li","year":"2021"},{"key":"ref33","article-title":"TSFEL: Time series feature extraction library","volume-title":"SoftwareX","volume":"11","author":"Barandas","year":"2020"},{"issue":"4","key":"ref34","article-title":"Optimal signal quality index for photoplethysmogram signals","volume":"3","author":"Elgendi","year":"2016"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6579\/abc8dd"},{"issue":"8","key":"ref36","first-page":"1226","article-title":"Feature selection based on mutual information criteria of max-dependency, max-relevance, and min-redundancy","volume-title":"IEEE Trans. Pattern Anal. Mach. Intell.","volume":"27","author":"Peng","year":"2005"},{"key":"ref37","article-title":"PPFS: Predictive permutation feature selection","author":"Hassan","year":"2021"},{"key":"ref38","article-title":"Review of causal discovery methods based on graphical models","volume-title":"Front. Genet.","volume":"10","author":"Glymour","year":"2019"},{"key":"ref39","first-page":"21","article-title":"HITON: A novel Markov blanket algorithm for optimal variable selection","volume-title":"Proc. AMIA Annu. Symp. Proc.","author":"Aliferis","year":"2003"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.1016\/j.eswa.2021.115222"},{"key":"ref41","volume-title":"IEEE standard for wearable cuffless blood pressure measuring devices","year":"2014"},{"key":"ref42","article-title":"American national standards for electronic or automated sphygmomanometers","year":"1987"},{"issue":"6","key":"ref43","first-page":"677","article-title":"Short report: An outline of the revised British hypertension society protocol for the evaluation of blood pressure measuring devices","volume-title":"J. Hypertension","volume":"11","author":"OBrien","year":"1993"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1146\/annurev-statistics-030718-104938"},{"key":"ref45","first-page":"1","article-title":"Sinkhorn distances: Lightspeed computation of optimal transport","volume-title":"Proc. Annu. Conf. Neural Inf. Process. Syst.","author":"Cuturi","year":"2013"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.1161\/hyp.0000000000000065"},{"issue":"2","key":"ref47","article-title":"Cuffless blood pressure measurement using linear and nonlinear optimized feature selection","volume-title":"Diagnostics","volume":"12","author":"Mamun","year":"2022"},{"key":"ref48","doi-asserted-by":"publisher","DOI":"10.1166\/jmihi.2018.2474"},{"issue":"6","key":"ref49","first-page":"1730","article-title":"A novel continuous blood pressure estimation approach based on data mining techniques","volume-title":"IEEE J. Biomed. Health Inform.","volume":"21","author":"Miao","year":"2017"},{"issue":"1","key":"ref50","article-title":"Pulse transit time based continuous cuffless blood pressure estimation: A new extension and a comprehensive evaluation","volume-title":"Sci. Rep.","volume":"7","author":"Ding","year":"2017"},{"issue":"8","key":"ref51","first-page":"3697","article-title":"DeepCNAP: A deep learning approach for continuous noninvasive arterial blood pressure monitoring using photoplethysmography","volume-title":"IEEE J. Biomed. Health Inform.","volume":"26","author":"Kim","year":"2022"},{"issue":"2","key":"ref52","first-page":"83","article-title":"Recursive feature elimination with random forest for PTR-MS analysis of agroindustrial products","volume-title":"Chemometrics Intell. Lab. Syst.","volume":"83","author":"Granitto","year":"2006"}],"container-title":["IEEE Journal of Biomedical and Health Informatics"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx8\/6221020\/10704792\/10552318.pdf?arnumber=10552318","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,15]],"date-time":"2025-01-15T20:05:44Z","timestamp":1736971544000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10552318\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10]]},"references-count":52,"journal-issue":{"issue":"10"},"URL":"https:\/\/doi.org\/10.1109\/jbhi.2024.3411693","relation":{},"ISSN":["2168-2194","2168-2208"],"issn-type":[{"value":"2168-2194","type":"print"},{"value":"2168-2208","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10]]}}}