{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,4]],"date-time":"2026-03-04T17:34:38Z","timestamp":1772645678886,"version":"3.50.1"},"reference-count":45,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"4","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"},{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"funder":[{"DOI":"10.13039\/501100012166","name":"National Key Research and Development Program of China","doi-asserted-by":"publisher","award":["2022YFB4400800"],"award-info":[{"award-number":["2022YFB4400800"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE J. Solid-State Circuits"],"published-print":{"date-parts":[[2025,4]]},"DOI":"10.1109\/jssc.2024.3516040","type":"journal-article","created":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T19:25:27Z","timestamp":1734636327000},"page":"1411-1422","source":"Crossref","is-referenced-by-count":4,"title":["A 97.3-dB SNR Bioimpedance AFE With \u221284-dB THD Segmented- \u0394\u03a3 M Sinusoidal Current Generator and Passing-Through Instrumentation Amplifier"],"prefix":"10.1109","volume":"60","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7424-0865","authenticated-orcid":false,"given":"Qinjing","family":"Pan","sequence":"first","affiliation":[{"name":"State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China"}]},{"given":"Qi","family":"Luo","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2244-736X","authenticated-orcid":false,"given":"Tianxiang","family":"Qu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7084-3757","authenticated-orcid":false,"given":"Liheng","family":"Liu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China"}]},{"given":"Xiao","family":"Li","sequence":"additional","affiliation":[{"name":"Chipsea Technologies Corporation, Shenzhen, China"}]},{"given":"Min","family":"Chen","sequence":"additional","affiliation":[{"name":"Chipsea Technologies Corporation, Shenzhen, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9968-5964","authenticated-orcid":false,"given":"Zhiliang","family":"Hong","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4150-0971","authenticated-orcid":false,"given":"Jiawei","family":"Xu","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1109\/RBME.2020.3041053"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-030-71752-0"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.2196\/22911"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1109\/OJCAS.2021.3075302"},{"key":"ref5","article-title":"Respiration rate measurement based on impedance pneumography","author":"Gupta","year":"2011"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/tbcas.2013.2297353"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/TBCAS.2018.2878395"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2015.2464705"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1109\/ISSCC.2019.8662352"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2022.3221478"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2020.2991511"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2020.3032723"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.118.010998"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/isscc19947.2020.9063112"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/cicc.2018.8357025"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2019.2939077"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/isscc42613.2021.9365801"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2014.2380781"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2021.3100716"},{"key":"ref20","volume-title":"Safe Current Limits for Electromedical Apparatus","year":"1993"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2022.3199492"},{"key":"ref22","first-page":"1","article-title":"A 97.3dB SNR bioimpedance AFE with -84dB THD segmented-\u0394\u03a3M sinusoidal current generator and passing-through instrumentation amplifier","volume-title":"Proc. IEEE Symp. VLSI Technol. Circuits (VLSI Technol. Circuits)","author":"Pan"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2010.2074350"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2017.2753234"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1109\/TBCAS.2024.3370399"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1109\/VLSITechnologyandCir46783.2024.10631313"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1109\/ISSCC49657.2024.10454399"},{"key":"ref28","first-page":"357","article-title":"A 3.8 mW 1.9 m\u03a9\/\u221aHz electrical impedance tomography imaging with 28.4 m\u03a9 high input impedance and loading calibration","volume-title":"Proc. ESSCIRC IEEE 49th Eur. Solid State Circuits Conf. (ESSCIRC)","author":"Um"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/ESSCIRC59616.2023.10268742"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1109\/LSSC.2018.2855429"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1109\/TBCAS.2022.3171163"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2008.2006462"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1109\/TCSII.2015.2483258"},{"key":"ref34","first-page":"332","article-title":"A 0.5mO\/vHz 106dB SNR 0.45cm2 dry-electrode bioimpedance interface with current mismatch cancellation and boosted input impedance of 100MO at 50 kHz","volume-title":"Proc. IEEE Int. Solid- State Circuits Conf. (ISSCC)","volume":"65","author":"Pan"},{"key":"ref35","first-page":"2023","article-title":"A PVT-insensitive sub-ranging current reference achieving 11.4ppm\/\u2218C from -20 \u2218C to 125 \u2218C","volume-title":"IEEE Int. Solid-State Circuits Conf. Dig. Tech. Papers, Feb.","author":"Park"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1109\/TCSII.2018.2828600"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1109\/4.735526"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2008.2006314"},{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2007.908664"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.1109\/4.535417"},{"key":"ref41","volume-title":"Analog Design Essentials","author":"Sansen","year":"2006"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2014.2359962"},{"key":"ref43","first-page":"5","article-title":"A 2-Electrode ECG amplifier with 0.5% nominal gain shift and 0.13% THD in a 530 mVpp input common-mode range","volume-title":"Proc. IEEE Asian Solid-State Circuits Conf. (A-SSCC)","author":"Xu"},{"issue":"9","key":"ref44","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/JSSC.2023.3269671","article-title":"A 26.6\u2013119.3-\u03bc w 101.9-dB SNR direct digitization bio-impedance readout IC","volume":"58","author":"Zhang","year":"2023","journal-title":"IEEE J. Solid-State Circuits"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1109\/LSSC.2023.3318815"}],"container-title":["IEEE Journal of Solid-State Circuits"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx8\/4\/10944491\/10810349.pdf?arnumber=10810349","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,29]],"date-time":"2025-03-29T03:34:02Z","timestamp":1743219242000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10810349\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":45,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.1109\/jssc.2024.3516040","relation":{},"ISSN":["0018-9200","1558-173X"],"issn-type":[{"value":"0018-9200","type":"print"},{"value":"1558-173X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]}}}