{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,18]],"date-time":"2025-10-18T10:35:35Z","timestamp":1760783735442},"reference-count":47,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"3","license":[{"start":{"date-parts":[[2014,9,1]],"date-time":"2014-09-01T00:00:00Z","timestamp":1409529600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"}],"funder":[{"name":"Funda\u00e7\u00e3o para a Ci\u00eancia e a Tecnologia","award":["SFRH\/BDE\/15624\/2006"],"award-info":[{"award-number":["SFRH\/BDE\/15624\/2006"]}]},{"name":"Siemens S.A. Healthcare Sector"},{"name":"Instituto de Telecomunica\u00e7\u00f5es, University of Beira Interior, Portugal"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Systems Journal"],"published-print":{"date-parts":[[2014,9]]},"DOI":"10.1109\/jsyst.2013.2284101","type":"journal-article","created":{"date-parts":[[2013,10,16]],"date-time":"2013-10-16T18:03:42Z","timestamp":1381946622000},"page":"929-938","source":"Crossref","is-referenced-by-count":17,"title":["Classification of Breast Masses on Contrast-Enhanced Magnetic Resonance Images Through Log Detrended Fluctuation Cumulant-Based Multifractal Analysis"],"prefix":"10.1109","volume":"8","author":[{"given":"Filipe","family":"Soares","sequence":"first","affiliation":[]},{"given":"Filipe","family":"Janela","sequence":"additional","affiliation":[]},{"given":"Manuela","family":"Pereira","sequence":"additional","affiliation":[]},{"given":"Joao","family":"Seabra","sequence":"additional","affiliation":[]},{"given":"Mario M.","family":"Freire","sequence":"additional","affiliation":[]}],"member":"263","reference":[{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevE.74.061104"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2009.05.003"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.5566\/ias.v20.p169-174"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-008-0276-8"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1109\/PACRIM.2009.5291288"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1118\/1.3446799"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1109\/MEMEA.2010.5480209"},{"key":"ref36","first-page":"16103-1","article-title":"Wavelet versus detrended fluctuation analysis of multifractal structures","volume":"74","author":"o?wiecimka","year":"2006","journal-title":"Phys Rev E Stat Nonlin Soft Matter Phys"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevE.49.1685"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1016\/S0378-4371(02)01383-3"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2012.02.011"},{"key":"ref40","author":"peitgen","year":"1993","journal-title":"Chaos and Fractals New Frontiers of Science"},{"key":"ref11","first-page":"3681","article-title":"Mammogram enhancement using alpha weighted quadratic filter","author":"zhou","year":"0","journal-title":"Proc 31st Annu Int Conf IEEE Eng Med Biol Soc"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/IPTA.2010.5586759"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/TITB.2011.2164259"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1053\/j.sult.2004.07.003"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1118\/1.598345"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/S1076-6332(99)80401-2"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1117\/12.387599","article-title":"Fractal discrimination of MRI breast masses using multiple segmentations","volume":"3979","author":"penn","year":"0","journal-title":"Proc SPIE"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1118\/1.1695652"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1118\/1.2210568"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2008.916959"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.05.0572"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1016\/j.artmed.2004.09.001"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1111\/j.1524-4741.2007.00513.x"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.213.3.r99dc01881"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/ISBI.2010.5490373"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1118\/1.2936220"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.211.1.r99ap38101"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/DICTA.2009.29"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1053\/sroe.2001.25116"},{"key":"ref9","first-page":"2299","article-title":"Response of MCF7 human breast cancer to tamoxifen: Evaluation by the three-time-point, contrast-enhanced magnetic resonance imaging method","volume":"4","author":"furman-haran","year":"1998","journal-title":"Clin Cancer Res"},{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.08.1229"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.2307\/2531595"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/JSTSP.2008.2011110"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1023\/A:1012487302797"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.20794"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.1002\/1522-2586(200012)12:6<965::AID-JMRI23>3.0.CO;2-1"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1118\/1.3151811"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1109\/MSP.2007.4286563"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2005.854517"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1007\/s100510170074"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1016\/S0730-725X(01)00222-3"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2010.5626792"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2009.01.029"},{"key":"ref43","author":"joachims","year":"1999","journal-title":"Making large-scale SVM learning practical"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2008.06.005"}],"container-title":["IEEE Systems Journal"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/4267003\/6881767\/06634209.pdf?arnumber=6634209","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,12]],"date-time":"2022-01-12T16:24:12Z","timestamp":1642004652000},"score":1,"resource":{"primary":{"URL":"http:\/\/ieeexplore.ieee.org\/document\/6634209\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,9]]},"references-count":47,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.1109\/jsyst.2013.2284101","relation":{},"ISSN":["1932-8184","1937-9234"],"issn-type":[{"value":"1932-8184","type":"print"},{"value":"1937-9234","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,9]]}}}