{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,2]],"date-time":"2025-11-02T11:48:00Z","timestamp":1762084080889,"version":"build-2065373602"},"reference-count":23,"publisher":"IEEE","license":[{"start":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T00:00:00Z","timestamp":1668556800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T00:00:00Z","timestamp":1668556800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,11,16]]},"DOI":"10.1109\/m2vip55626.2022.10041067","type":"proceedings-article","created":{"date-parts":[[2023,2,16]],"date-time":"2023-02-16T23:01:52Z","timestamp":1676588512000},"page":"1-6","source":"Crossref","is-referenced-by-count":2,"title":["Spiral Resonator-based Corneal Contact Lens For Intraocular Pressure Monitoring"],"prefix":"10.1109","author":[{"given":"Yiming","family":"Lu","sequence":"first","affiliation":[{"name":"College of Precision Instrument and Opto-electronics Engineering, Tianjin University,State Key Laboratory of Precision Measuring Technology and Instrument,Tianjin,China,300072"}]},{"given":"Wentuo","family":"Yang","sequence":"additional","affiliation":[{"name":"College of Precision Instrument and Opto-electronics Engineering, Tianjin University,State Key Laboratory of Precision Measuring Technology and Instrument,Tianjin,China,300072"}]},{"given":"Yan","family":"Wang","sequence":"additional","affiliation":[{"name":"Tianjin Medical University,Clinical College of Ophthalmology,Tianjin,China,300072"}]},{"given":"Qian","family":"Fan","sequence":"additional","affiliation":[{"name":"Tianjin Medical University,Clinical College of Ophthalmology,Tianjin,China,300072"}]},{"given":"Xuexin","family":"Duan","sequence":"additional","affiliation":[{"name":"College of Precision Instrument and Opto-electronics Engineering, Tianjin University,State Key Laboratory of Precision Measuring Technology and Instrument,Tianjin,China,300072"}]},{"given":"Mengying","family":"Xie","sequence":"additional","affiliation":[{"name":"College of Precision Instrument and Opto-electronics Engineering, Tianjin University,State Key Laboratory of Precision Measuring Technology and Instrument,Tianjin,China,300072"}]}],"member":"263","reference":[{"key":"ref1","first-page":"887","article-title":"Glaucoma is second leading cause of blindness globally","volume":"82","author":"Sharon","year":"2004","journal-title":"Bulletin of the World Health Organization"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.4103\/jovr.jovr_208_17"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1038\/nm.3621"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.optom.2018.12.003"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1021\/acsami.0c02991"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1039\/c8ra10257k"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1039\/d0tb01687j"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1039\/C9LC00735K"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1021\/acs.nanolett.9b03605"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2011.6090698"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2019.04.050"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2013.08.029"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2014.06.005"},{"key":"ref14","first-page":"e119","article-title":"Effect of overnight wear of the Triggerfish\u00ae sensor on corneal thickness measured by Visante\u00ae anterior segment optical coherence tomography","author":"Ralitsa","year":"2014","journal-title":"Acta ophthalmologica 92.2"},{"key":"ref15","first-page":"471","author":"Kyoseung","year":"2019","journal-title":"Three-dimensional curvy electronics created using conformal additive stamp printing"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1103\/physrevb.69.014402"},{"key":"ref17","first-page":"626","article-title":"Accurate extraction of equivalent circuit parameters of spiral resonators for the design of metamaterials","author":"Danilo","year":"2018","journal-title":"IEEE Transactions on Microwave Theory and Techniques 67.2"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1109\/22.552045"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1007\/s00542-018-4137-2"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1039\/c7lc00046d"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1021\/acsami.8b02320"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1063\/5.0075446"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1046\/j.1475-1313.1997.97000239.x"}],"event":{"name":"2022 28th International Conference on Mechatronics and Machine Vision in Practice (M2VIP)","start":{"date-parts":[[2022,11,16]]},"location":"Nanjing, China","end":{"date-parts":[[2022,11,18]]}},"container-title":["2022 28th International Conference on Mechatronics and Machine Vision in Practice (M2VIP)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/10041021\/10041042\/10041067.pdf?arnumber=10041067","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,2]],"date-time":"2024-03-02T19:03:46Z","timestamp":1709406226000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10041067\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,16]]},"references-count":23,"URL":"https:\/\/doi.org\/10.1109\/m2vip55626.2022.10041067","relation":{},"subject":[],"published":{"date-parts":[[2022,11,16]]}}}