{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T15:53:01Z","timestamp":1776441181568,"version":"3.51.2"},"reference-count":35,"publisher":"IEEE","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,7,1]]},"DOI":"10.1109\/metroind4.0iot66048.2025.11122050","type":"proceedings-article","created":{"date-parts":[[2025,8,19]],"date-time":"2025-08-19T18:08:07Z","timestamp":1755626887000},"page":"342-347","source":"Crossref","is-referenced-by-count":1,"title":["Experimental Assessment of a 3D-Printed FBG-Based Forceps for Minimally Invasive Surgery: Gripping Tests on Ex Vivo Animal Tissues"],"prefix":"10.1109","author":[{"given":"Vincenzo","family":"Lavorgna","sequence":"first","affiliation":[{"name":"Universit&#x00E0; Campus Bio-Medico di Roma,Department of Engineering,Rome,Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martina","family":"Pucinelli","sequence":"additional","affiliation":[{"name":"Universit&#x00E0; Campus Bio-Medico di Roma,Department of Engineering,Rome,Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlo","family":"Massaroni","sequence":"additional","affiliation":[{"name":"Universit&#x00E0; Campus Bio-Medico di Roma &#x0026; Fond. Pol. Campus Bio-Medico,Department of Engineering,Rome,Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guido","family":"Gabriele","sequence":"additional","affiliation":[{"name":"Universit&#x00E0; degli Studi di Siena,Department of Medical Biotechnologies,Siena,Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emiliano","family":"Schena","sequence":"additional","affiliation":[{"name":"Universit&#x00E0; Campus Bio-Medico di Roma &#x0026; Fond. Pol. Campus Bio-Medico,Department of Engineering,Rome,Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniela Lo","family":"Presti","sequence":"additional","affiliation":[{"name":"Universit&#x00E0; Campus Bio-Medico di Roma &#x0026; Fond. Pol. Campus Bio-Medico,Department of Engineering,Rome,Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0037-1608651"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4028649"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1055\/s-2004-814113"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-007-9727-5"},{"key":"ref5","article-title":"Tactile sensing and displays: haptic feedback for minimally invasive surgery and robotics","author":"Dargahi","year":"2012"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1080\/13645700701820242"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1162\/pres.16.3.252"},{"key":"ref8","article-title":"Force Control for Grasping Soft Tissue","author":"Stoll","year":"2006"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1109\/jsen.2008.917481"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.3389\/frobt.2021.705662"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1243\/09544062JMES1917"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1155\/2012\/412816"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/JSEN.2025.3557470"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/SR.2024.3513953"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/tim.2024.3497153"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/access.2020.3019138"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1063\/5.0251132"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.3390\/s140406633"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1109\/jsen.2021.3081444"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/jsen.2022.3224042"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1109\/ICRA.2017.7989114"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1049\/el.2013.4182"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1117\/12.909602"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1007\/s00170-022-08860-7"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1007\/978-981-19-4208-2_18"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1109\/JSEN.2022.3202101"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1063\/5.0226556"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2024.116236"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/50.618322"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.4018\/978-1-6684-5381-0.ch006"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1080\/02656736.2016.1230682"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.3109\/02656736.2014.928832"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.3390\/s140406633"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.3788\/col201614.120007"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-90755-0_6"}],"event":{"name":"2025 IEEE International Workshop on Metrology for Industry 4.0 &amp; IoT (MetroInd4.0 &amp; IoT)","location":"Castelldefels, Spain","start":{"date-parts":[[2025,7,1]]},"end":{"date-parts":[[2025,7,3]]}},"container-title":["2025 IEEE International Workshop on Metrology for Industry 4.0 &amp;amp; IoT (MetroInd4.0 &amp;amp; IoT)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx8\/11122018\/11121940\/11122050.pdf?arnumber=11122050","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T06:29:06Z","timestamp":1755671346000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/11122050\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,1]]},"references-count":35,"URL":"https:\/\/doi.org\/10.1109\/metroind4.0iot66048.2025.11122050","relation":{},"subject":[],"published":{"date-parts":[[2025,7,1]]}}}