{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T01:09:37Z","timestamp":1740100177542,"version":"3.37.3"},"reference-count":24,"publisher":"IEEE","license":[{"start":{"date-parts":[[2021,7,15]],"date-time":"2021-07-15T00:00:00Z","timestamp":1626307200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2021,7,15]],"date-time":"2021-07-15T00:00:00Z","timestamp":1626307200000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"funder":[{"DOI":"10.13039\/501100019976","name":"Jiaxing Science and Technology Bureau","doi-asserted-by":"publisher","award":["2019AY32021,2020AY30013"],"award-info":[{"award-number":["2019AY32021,2020AY30013"]}],"id":[{"id":"10.13039\/501100019976","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,7,15]]},"DOI":"10.1109\/rcar52367.2021.9517487","type":"proceedings-article","created":{"date-parts":[[2021,8,31]],"date-time":"2021-08-31T20:32:50Z","timestamp":1630441970000},"page":"1397-1401","source":"Crossref","is-referenced-by-count":2,"title":["Robot-Assisted quantitative assessment of axis misalignment of wrist joint"],"prefix":"10.1109","author":[{"given":"Dong","family":"Xu","sequence":"first","affiliation":[{"name":"Auckland Tongji Medical &#x0026; Rehabilitation Equipment Research Centre,Tongji Zhejiang College,Jiaxing,China"}]},{"given":"Han","family":"Xu","sequence":"additional","affiliation":[{"name":"Auckland Tongji Medical &#x0026; Rehabilitation Equipment Research Centre,Tongji Zhejiang College,Jiaxing,China"}]},{"given":"Ya","family":"Sun","sequence":"additional","affiliation":[{"name":"Rehabilitation Medical Centre, the Second Affiliated Hospital of Jiaxing University,Jiaxing,China"}]},{"given":"Yibin","family":"Li","sequence":"additional","affiliation":[{"name":"Auckland Tongji Medical &#x0026; Rehabilitation Equipment Research Centre,Tongji Zhejiang College,Jiaxing,China"}]},{"given":"Xu","family":"Zhang","sequence":"additional","affiliation":[{"name":"Auckland Tongji Medical &#x0026; Rehabilitation Equipment Research Centre,Tongji Zhejiang College,Jiaxing,China"}]},{"given":"Xiaolong","family":"Li","sequence":"additional","affiliation":[{"name":"Auckland Tongji Medical &#x0026; Rehabilitation Equipment Research Centre,Tongji Zhejiang College,Jiaxing,China"}]},{"given":"Jianming","family":"Fu","sequence":"additional","affiliation":[{"name":"Rehabilitation Medical Centre, the Second Affiliated Hospital of Jiaxing University,Jiaxing,China"}]}],"member":"263","reference":[{"key":"ref10","first-page":"1","article-title":"Low-profile Two-degree-of-freedom Wrist Exoskeleton Device using Multiple Spring Blade","volume":"pp","author":"higuma","year":"2017","journal-title":"IEEE l of Robotics and Automation"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2009.2019147"},{"key":"ref12","article-title":"Misalignment compensation as a way to ensure full human-exoskeleton kinematic compatibility: state of the art and evaluation","author":"naf","year":"2019","journal-title":"Applied Mechanics Reviews"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/BIOROB.2016.7523798"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/ICORR.2013.6650357"},{"key":"ref15","first-page":"1","article-title":"Self-Aligning Mechanism Improves Comfort and Performance with a Powered Knee Exoskeleton","volume":"pp","author":"sarkisian","year":"2021","journal-title":"IEEE Transactions on Neural Systems and Rehabilitation Engineering"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/AIM.2018.8452363"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2019.07.003"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2018.03.001"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2001.1020443"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1109\/TCDS.2021.3072096"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1023\/A:1024494031121"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/TASE.2020.2992890"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1109\/BIOROB.2006.1639236"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2007.903899"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1115\/IMECE2006-16103"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1109\/ICORR.2005.1501040"},{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1093\/ptj\/74.5.399"},{"journal-title":"ARMin III - arm therapy exoskeleton with an ergonomic shoulder actuation","year":"0","author":"nef","key":"ref9"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1519\/15184.1"},{"key":"ref22","article-title":"Evaluation and Verification of A Novel Wrist Rehabilitation Robot employing Safety-related Mechanism","author":"ju-hwan","year":"0","journal-title":"2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR)"},{"key":"ref21","article-title":"Statistical Methods for Health Care Research","author":"munro","year":"1995","journal-title":"Statistical Methods for Health Care Research"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.3390\/s100403180"},{"journal-title":"A simple camera tracking virtual reality system for evaluation of wrist range of motion","year":"2010","author":"eini","key":"ref23"}],"event":{"name":"2021 IEEE International Conference on Real-time Computing and Robotics (RCAR)","start":{"date-parts":[[2021,7,15]]},"location":"Xining, China","end":{"date-parts":[[2021,7,19]]}},"container-title":["2021 IEEE International Conference on Real-time Computing and Robotics (RCAR)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/9517075\/9517076\/09517487.pdf?arnumber=9517487","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,2]],"date-time":"2022-08-02T23:45:28Z","timestamp":1659483928000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/9517487\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,15]]},"references-count":24,"URL":"https:\/\/doi.org\/10.1109\/rcar52367.2021.9517487","relation":{},"subject":[],"published":{"date-parts":[[2021,7,15]]}}}