{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T08:47:22Z","timestamp":1769503642890,"version":"3.49.0"},"reference-count":20,"publisher":"IEEE","license":[{"start":{"date-parts":[[2022,10,30]],"date-time":"2022-10-30T00:00:00Z","timestamp":1667088000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2022,10,30]],"date-time":"2022-10-30T00:00:00Z","timestamp":1667088000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,10,30]]},"DOI":"10.1109\/sensors52175.2022.9967248","type":"proceedings-article","created":{"date-parts":[[2022,12,8]],"date-time":"2022-12-08T13:42:41Z","timestamp":1670506961000},"page":"01-04","source":"Crossref","is-referenced-by-count":3,"title":["Leakage Sensor Placement Optimization Using Acoustic Attenuation Features in Water Mains"],"prefix":"10.1109","author":[{"given":"Akihiro","family":"Koyama","sequence":"first","affiliation":[{"name":"Hitachi, Ltd.,Research &#x0026; Development Group,Tokyo,Japan"}]},{"given":"Yusuke","family":"Sugita","sequence":"additional","affiliation":[{"name":"Hitachi, Ltd.,Research &#x0026; Development Group,Tokyo,Japan"}]},{"given":"Atsushi","family":"Isobe","sequence":"additional","affiliation":[{"name":"Hitachi, Ltd.,Research &#x0026; Development Group,Tokyo,Japan"}]},{"given":"Yudai","family":"Kamada","sequence":"additional","affiliation":[{"name":"Hitachi America, Ltd.,Research &#x0026; Development Group,California,U.S.A."}]},{"given":"Munenori","family":"Degawa","sequence":"additional","affiliation":[{"name":"Hitachi, Ltd.,Research &#x0026; Development Group,Tokyo,Japan"}]},{"given":"Toshiyuki","family":"Mine","sequence":"additional","affiliation":[{"name":"Hitachi, Ltd.,Research &#x0026; Development Group,Tokyo,Japan"}]},{"given":"Takashi","family":"Kawamoto","sequence":"additional","affiliation":[{"name":"Hitachi, Ltd.,Research &#x0026; Development Group,Tokyo,Japan"}]}],"member":"263","reference":[{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1109\/JSEN.2019.2948172"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2020.2991533"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/SENSORS47087.2021.9639707"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.3390\/s131114984"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.jprocont.2020.08.003"},{"key":"ref15","first-page":"ii333","article-title":"A Planninng Model for Optimal Deployment of Leak Sensors in A Water Pipeline Network","volume":"72","author":"arai","year":"2016","journal-title":"Journal of Japan Society of Civil Engineers Environmental Research"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1016\/S0041-624X(03)00166-5"},{"key":"ref17","article-title":"Analysis of the frequency-dependent attenuation of transient pressure waves in plastic pipes","author":"jinzhe","year":"0","journal-title":"WDSA \/ CCWI 2018 Proceedings of the Water Distribution System Analysis & Computing and Control for the Water Industry Joint Conference"},{"key":"ref18","article-title":"Detecting sound waves generated by leaks in buried water distribution pipes","author":"kirby","year":"2017","journal-title":"Acoustics"},{"key":"ref19","author":"mitchell","year":"0","journal-title":"PuLP A Linear Programming Toolkit for Python"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2019.2896302"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.5610\/jaee.16.8_145"},{"key":"ref6","article-title":"A Review of Inspection Methods for Continuously Monitoring PVC Drinking Water Mains","author":"tran","year":"2021","journal-title":"IEEE Internet of Things Journal"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.2166\/9781789060850"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.scitotenv.2021.151110"},{"key":"ref7","first-page":"3057","article-title":"Leak acoustic detection in water distribution pipelines","author":"yang","year":"2018","journal-title":"2008 7th World Congress on Intelligent Control and Automation"},{"key":"ref2","article-title":"Labour and Welfare 2017 About the Present Conditions of Water Supply","year":"2017","journal-title":"Ministry of Health"},{"key":"ref1","first-page":"1","author":"folkman","year":"2018","journal-title":"Water Main Break Rates in the USA and Canada A Comprehensive Study"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1109\/JMEMS.2019.2903349"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1287\/educ.1053.0020"}],"event":{"name":"2022 IEEE Sensors","location":"Dallas, TX, USA","start":{"date-parts":[[2022,10,30]]},"end":{"date-parts":[[2022,11,2]]}},"container-title":["2022 IEEE Sensors"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/9966996\/9966997\/09967248.pdf?arnumber=9967248","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,26]],"date-time":"2022-12-26T14:47:20Z","timestamp":1672066040000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/9967248\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,30]]},"references-count":20,"URL":"https:\/\/doi.org\/10.1109\/sensors52175.2022.9967248","relation":{},"subject":[],"published":{"date-parts":[[2022,10,30]]}}}