{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T14:21:54Z","timestamp":1768832514014,"version":"3.49.0"},"reference-count":16,"publisher":"IEEE","license":[{"start":{"date-parts":[[2024,10,20]],"date-time":"2024-10-20T00:00:00Z","timestamp":1729382400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,10,20]],"date-time":"2024-10-20T00:00:00Z","timestamp":1729382400000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,10,20]]},"DOI":"10.1109\/sensors60989.2024.10784813","type":"proceedings-article","created":{"date-parts":[[2024,12,17]],"date-time":"2024-12-17T19:07:24Z","timestamp":1734462444000},"page":"1-4","source":"Crossref","is-referenced-by-count":1,"title":["A High-Performance Mode-Localized Vacuum Gauge Based on FPGA Closed-Loop Control"],"prefix":"10.1109","author":[{"given":"Jiaxin","family":"Qin","sequence":"first","affiliation":[{"name":"Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mengyang","family":"Zhou","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junbo","family":"Wang","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Deyong","family":"Chen","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bo","family":"Xie","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yulan","family":"Lu","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nan","family":"Li","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhaoyuan","family":"Tan","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jian","family":"Chen","sequence":"additional","affiliation":[{"name":"Aerospace Information Research Institute,Chinese Academy of Sciences,Beijing,China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.vacuum.2020.109880"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2010.08.015"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.vacuum.2021.110065"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6439\/ad1b1a"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1109\/LSENS.2019.2949047"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.vacuum.2021.110446"},{"key":"ref7","volume-title":"MKS Instruments. DA06A capacitance manometer datasheet","year":"2024"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/SENSORS56945.2023.10325141"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1109\/JMEMS.2017.2787544"},{"key":"ref10","first-page":"3001510","article-title":"Direct measuring the amplitude ratios of weakly coupled resonators employing automatic","volume":"70","author":"Guo","year":"2012","journal-title":"IEEE T. Instru. Meas"},{"key":"ref11","volume-title":"A MEMS sensor for stiffness change sensing applications based on three weakly coupled resonators","author":"Zhao","year":"2016"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1049\/el.2018.0353"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/JMEMS.2016.2580529"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1038\/micronano.2017.23"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/JSEN.2024.3365864"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/TED.2022.3213525"}],"event":{"name":"2024 IEEE SENSORS","location":"Kobe, Japan","start":{"date-parts":[[2024,10,20]]},"end":{"date-parts":[[2024,10,23]]}},"container-title":["2024 IEEE SENSORS"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx8\/10783834\/10784457\/10784813.pdf?arnumber=10784813","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T06:15:35Z","timestamp":1734588935000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10784813\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,20]]},"references-count":16,"URL":"https:\/\/doi.org\/10.1109\/sensors60989.2024.10784813","relation":{},"subject":[],"published":{"date-parts":[[2024,10,20]]}}}