{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T23:35:04Z","timestamp":1781739304023,"version":"3.54.5"},"reference-count":22,"publisher":"IEEE","license":[{"start":{"date-parts":[[2019,9,1]],"date-time":"2019-09-01T00:00:00Z","timestamp":1567296000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"},{"start":{"date-parts":[[2019,9,1]],"date-time":"2019-09-01T00:00:00Z","timestamp":1567296000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2019,9,1]],"date-time":"2019-09-01T00:00:00Z","timestamp":1567296000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,9]]},"DOI":"10.1109\/systol.2019.8864749","type":"proceedings-article","created":{"date-parts":[[2019,10,15]],"date-time":"2019-10-15T00:25:36Z","timestamp":1571099136000},"page":"110-116","source":"Crossref","is-referenced-by-count":5,"title":["Fault detection and isolation system for four-wheels drive electric vehicles"],"prefix":"10.1109","author":[{"given":"Boulaid","family":"Boulkroune","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastiaan","family":"van Aalst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ellen","family":"van Nunen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoann","family":"Descas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"263","reference":[{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1109\/TVT.2016.2604759"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2012.2183835"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1177\/1077546309106525"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.automatica.2008.07.017"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1243\/PIME_AUTO_1956_000_032_02"},{"key":"ref15","year":"2014","journal-title":"E-VECTOORC"},{"key":"ref16","year":"2016","journal-title":"ICOMPOSE"},{"key":"ref17","author":"hrastovak","year":"2018","journal-title":"Modeling and identification of passenger car dynamics Flanders Make internal report"},{"key":"ref18","article-title":"Active vibration control for torsional oscillations in powertrains for fully electric vehicles","author":"orus","year":"2014","journal-title":"FISITA 2014 - Special Session &#x2018;Vehicle Dynamics Control for Fully Electric Vehicles Outcomes of the European Project E-VECTOORC&#x2019;"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1115\/DSCC2008-2152"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s12206-009-0357-9"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1076\/vesd.36.2.77.3554"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1177\/0954407016643225"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1109\/CDC.2014.7040418"},{"key":"ref8","author":"yi","year":"2001","journal-title":"Fault detection and handling for longitudinal control California PATH Research Report UCB-ITS-P RR-2001&#x2013;21"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/87.930966"},{"key":"ref2","author":"blanke","year":"2006","journal-title":"Diagnosis and Fault-Tolerant Control"},{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1016\/S0967-0661(97)00049-X"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/279086"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/TCST.2012.2213088"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1109\/IVS.2017.7995739"},{"key":"ref21","author":"glvez-carrillo","year":"2010","journal-title":"Combined Signal and Model-Based Sensor Fault Diagnosis for a Doubly Fed Induction Generator"}],"event":{"name":"2019 4th Conference on Control and Fault Tolerant Systems (SysTol)","location":"Casablanca, Morocco","start":{"date-parts":[[2019,9,18]]},"end":{"date-parts":[[2019,9,20]]}},"container-title":["2019 4th Conference on Control and Fault Tolerant Systems (SysTol)"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/8854871\/8864730\/08864749.pdf?arnumber=8864749","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,18]],"date-time":"2022-07-18T15:19:22Z","timestamp":1658157562000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/8864749\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,9]]},"references-count":22,"URL":"https:\/\/doi.org\/10.1109\/systol.2019.8864749","relation":{},"subject":[],"published":{"date-parts":[[2019,9]]}}}