{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T16:41:27Z","timestamp":1774629687301,"version":"3.50.1"},"reference-count":38,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"6","license":[{"start":{"date-parts":[[2016,12,1]],"date-time":"2016-12-01T00:00:00Z","timestamp":1480550400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Biomed. Circuits Syst."],"published-print":{"date-parts":[[2016,12]]},"DOI":"10.1109\/tbcas.2016.2518923","type":"journal-article","created":{"date-parts":[[2016,4,19]],"date-time":"2016-04-19T20:02:48Z","timestamp":1461096168000},"page":"1171-1180","source":"Crossref","is-referenced-by-count":19,"title":["Exploiting Electrocorticographic Spectral Characteristics for Optimized Signal Chain Design: A 1.08 W Analog Front End With Reduced ADC Resolution Requirements&lt;formula formulatype=\"inline\"&gt; &lt;tex Notation=\"TeX\"\/&gt; &lt;\/formula&gt;"],"prefix":"10.1109","volume":"10","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4958-9712","authenticated-orcid":false,"given":"William A.","family":"Smith","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian J.","family":"Mogen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eberhard E.","family":"Fetz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Visvesh S.","family":"Sathe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brian P.","family":"Otis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2011.2163552"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1109\/TBCAS.2013.2293821"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2009.5334436"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1109\/TBCAS.2013.2288680"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1109\/BioCAS.2011.6107721"},{"key":"ref37","first-page":"193","article-title":"An ultra-low-power frontend neural interface with automatic gain for uncalibrated monitoring","author":"paraskevopoulou","year":"2012","journal-title":"Proc IEEE Int Symp Circuits and Systems"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2012.2213842"},{"key":"ref35","author":"jacob baker","year":"2009","journal-title":"CMOS Mixed-Signal Circuit Design"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2003.811979"},{"key":"ref10","author":"penfield","year":"1954","journal-title":"Epilepsy and the Functional Anatomy of the Human Brain"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/RBME.2011.2172408"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuron.2011.11.006"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"3968","DOI":"10.1152\/jn.1996.76.6.3968","article-title":"Synchronization of neurons during local field potential oscillations in sensorimotor cortex of awake monkeys","volume":"76","author":"murthy","year":"1996","journal-title":"J Neurophys"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/0166-2236(92)90039-B"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1093\/acprof:oso\/9780195050387.001.0001"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1038\/nrn3241"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.57.11.2045"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/S1388-2457(00)00545-9","article-title":"Induced electrocorticographic gamma activity during auditory perception","volume":"112","author":"crone","year":"2001","journal-title":"Clin Neurophys"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2012.10.020"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pcbi.1000609"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"3025","DOI":"10.1109\/JSSC.2008.2006462","article-title":"A 200 <ref_formula><tex Notation=\"TeX\">$\\mu{\\rm W}$<\/tex><\/ref_formula> eight- channel EEG acquisition ASIC for ambulatory EEG systems","volume":"43","author":"yazicioglu","year":"2008","journal-title":"IEEE J Solid-State Circuits"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1109\/ESSCIRC.2014.6942033"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"2934","DOI":"10.1109\/JSSC.2007.908664","article-title":"A 2 <ref_formula><tex Notation=\"TeX\">$\\mu{\\rm W}$<\/tex><\/ref_formula> 100 nV\/rtHz Chopper-stabilized instrumentation amplifier for chronic measurement of neural field potentials","volume":"42","author":"denison","year":"2007","journal-title":"IEEE J Solid-State Circuits"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/JETCAS.2011.2180835"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.1987.1052869"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1109\/TCSI.2011.2163972"},{"key":"ref8","first-page":"412","article-title":"A miniaturized 64-channel 225 <ref_formula><tex Notation=\"TeX\">$\\mu{\\rm W}$<\/tex><\/ref_formula> wireless electrocorticographic neural sensor","author":"muller","year":"2014","journal-title":"IEEE ISSCC Tech Dig"},{"key":"ref7","first-page":"141","article-title":"85 db dynamic range 1.2 mW 156 kS\/s biopotential recording IC for highdensity ECoG flexible active electrode array","author":"ha","year":"2013","journal-title":"Proc ESSCIRC"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1523\/JNEUROSCI.5506-08.2009"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/1\/2\/001"},{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/5\/1\/008"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1523\/JNEUROSCI.3886-06.2007"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1016\/S0079-6123(06)59019-3"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1093\/brain\/121.12.2301"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/6\/6\/066001"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1002\/ana.22613"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/11\/4\/046011"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1016\/j.nurt.2007.10.069"}],"container-title":["IEEE Transactions on Biomedical Circuits and Systems"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/4156126\/7802655\/07448483.pdf?arnumber=7448483","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,12]],"date-time":"2022-01-12T16:12:12Z","timestamp":1642003932000},"score":1,"resource":{"primary":{"URL":"http:\/\/ieeexplore.ieee.org\/document\/7448483\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12]]},"references-count":38,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.1109\/tbcas.2016.2518923","relation":{},"ISSN":["1932-4545","1940-9990"],"issn-type":[{"value":"1932-4545","type":"print"},{"value":"1940-9990","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,12]]}}}