{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T06:29:05Z","timestamp":1793860145971,"version":"4.6.1"},"reference-count":24,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"2","license":[{"start":{"date-parts":[[2013,2,1]],"date-time":"2013-02-01T00:00:00Z","timestamp":1359676800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Biomed. Eng."],"published-print":{"date-parts":[[2013,2]]},"DOI":"10.1109\/tbme.2012.2227318","type":"journal-article","created":{"date-parts":[[2012,11,21]],"date-time":"2012-11-21T15:10:04Z","timestamp":1353510604000},"page":"417-426","source":"Crossref","is-referenced-by-count":19,"title":["Advantages and Limitations of Using Matrix Pencil Method for the Modal Analysis of Medical Percussion Signals"],"prefix":"10.1109","volume":"60","author":[{"given":"Moinuddin","family":"Bhuiyan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eugene V.","family":"Malyarenko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mircea A.","family":"Pantea","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fedar M.","family":"Seviaryn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roman","family":"Gr. Maev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1007\/BF02478184"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.95.08101756"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1007\/BF02345077"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1989.66.1.273"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1007\/BF02345450"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1049\/cp:20010163"},{"key":"ref7","first-page":"161","article-title":"Spectrum estimation methods for signal analysis in the supply system of a DC arc furnace","volume-title":"Proc. 13th Int. Symp. Theor. Electr. Eng.","author":"Zbigniew"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1121\/1.407519"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1109\/ICHQP.2008.4668751"},{"key":"ref10","first-page":"612","article-title":"Power system interharmonics monitoring based on wavelet transform and AR model","volume-title":"Proc. Comput. Intell. Ind. Appl., Pacific-Asia Workshop","author":"Zhenmei"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/TCSII.2006.883100"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2005.862015"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/PROC.1981.12184"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1006\/dspr.1996.0011"},{"issue":"11","key":"ref15","first-page":"2081","article-title":"A model order estimation in the matrix pencil method for the transient response of a microwave circuit discontinuity","volume":"E82-C","author":"Kitamura","year":"1999","journal-title":"IEICE Trans. Electron."},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2009.2032551"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/TASSP.1982.1163974"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1109\/74.370583"},{"key":"ref19","article-title":"Scattering centers measurements using a modified matrix pencil method","volume-title":"8th Int. Conf. Signal Process.","author":"Shiyong"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1134\/1.1983603"},{"key":"ref21","volume-title":"Theory of Matrices","volume":"1","author":"Gantmacher","year":"1960"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1121\/1.3665985"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1109\/29.56027"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1109\/ICASSP.2000.862122"}],"container-title":["IEEE Transactions on Biomedical Engineering"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx5\/10\/6413218\/06353178.pdf?arnumber=6353178","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T06:00:42Z","timestamp":1793858442000},"score":1,"resource":{"primary":{"URL":"http:\/\/ieeexplore.ieee.org\/document\/6353178\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,2]]},"references-count":24,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.1109\/tbme.2012.2227318","relation":{},"ISSN":["0018-9294","1558-2531"],"issn-type":[{"value":"0018-9294","type":"print"},{"value":"1558-2531","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,2]]}}}