{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,1]],"date-time":"2026-02-01T05:47:04Z","timestamp":1769924824929,"version":"3.49.0"},"reference-count":24,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"5","license":[{"start":{"date-parts":[[2015,5,1]],"date-time":"2015-05-01T00:00:00Z","timestamp":1430438400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"}],"funder":[{"DOI":"10.13039\/100008875","name":"University of Akron","doi-asserted-by":"crossref","id":[{"id":"10.13039\/100008875","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Biomed. Eng."],"published-print":{"date-parts":[[2015,5]]},"DOI":"10.1109\/tbme.2014.2386136","type":"journal-article","created":{"date-parts":[[2014,12,24]],"date-time":"2014-12-24T14:47:43Z","timestamp":1419432463000},"page":"1316-1323","source":"Crossref","is-referenced-by-count":46,"title":["An Inductive Sensor for Real-Time Measurement of Plantar Normal and Shear Forces Distribution"],"prefix":"10.1109","volume":"62","author":[{"given":"Li","family":"Du","sequence":"first","affiliation":[]},{"given":"Xiaoliang","family":"Zhu","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5452-549X","authenticated-orcid":false,"given":"Jiang","family":"Zhe","sequence":"additional","affiliation":[]}],"member":"263","reference":[{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1088\/0957-0233\/23\/10\/105705"},{"key":"ref11","article-title":"Development and characterization of a high-spatial-temporal-resolution foot-sole-pressure measurement system","author":"kalamdani","year":"2006"},{"key":"ref12","article-title":"An early detection system for foot ulceration in diabetic patients","author":"bernard","year":"0"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"766","DOI":"10.20965\/jrm.2012.p0766","article-title":"Insole-type simultaneous measurement system of plantar pressure and shear force during gait for diabetic patients","volume":"24","author":"mori","year":"2012","journal-title":"J Robot Mechatron"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1123\/jab.14.1.93","article-title":"A device for simultaneous measurement of pressure and shear force distribution on the plantar surface of the foot","volume":"14","author":"davis","year":"1998","journal-title":"J Appl Biomech"},{"key":"ref15","doi-asserted-by":"crossref","DOI":"10.1117\/12.914979","article-title":"Pressure and shear sensing based on microstrip antennas","author":"mohammad","year":"2012"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1049\/ip-a-3.1992.0004","article-title":"three-dimensional displacement and force transducer","volume":"139","author":"warren-forward","year":"1992","journal-title":"Science Measurement and Technology IEE Proceedings A"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2014.04.009"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1088\/0964-1726\/23\/6\/065018"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1007\/s11249-013-0179-x"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2007.02.006"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2014.2322993"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1001\/jama.293.2.217"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2007.10.008"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1177\/193229681300700218"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.2337\/dc06-1600"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1016\/S0966-6362(01)00176-X"},{"key":"ref1","article-title":"Global health risks: Mortality and burden of disease attributable to selected major risks","year":"2009"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1145\/2413097.2413107"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1088\/0957-0233\/24\/7\/075106"},{"key":"ref22","first-page":"1105","article-title":"Analysis and interpretation of ground reaction forces in normal gait","volume":"8","author":"marasovic","year":"2009","journal-title":"WSEAS Trans Syst"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2010.03.036"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1088\/0957-0233\/10\/1\/017"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1053\/apmr.2001.16347"}],"container-title":["IEEE Transactions on Biomedical Engineering"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/10\/7088669\/06998018.pdf?arnumber=6998018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,12]],"date-time":"2022-01-12T11:41:54Z","timestamp":1641987714000},"score":1,"resource":{"primary":{"URL":"http:\/\/ieeexplore.ieee.org\/document\/6998018\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,5]]},"references-count":24,"journal-issue":{"issue":"5"},"URL":"https:\/\/doi.org\/10.1109\/tbme.2014.2386136","relation":{},"ISSN":["0018-9294","1558-2531"],"issn-type":[{"value":"0018-9294","type":"print"},{"value":"1558-2531","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,5]]}}}