{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,28]],"date-time":"2026-03-28T16:42:12Z","timestamp":1774716132602,"version":"3.50.1"},"reference-count":39,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"10","license":[{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"},{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["NIH P41EB015894"],"award-info":[{"award-number":["NIH P41EB015894"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["NIH S10 RR25437"],"award-info":[{"award-number":["NIH S10 RR25437"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["NIH P30 NS076408"],"award-info":[{"award-number":["NIH P30 NS076408"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["NIH R21 EB009133"],"award-info":[{"award-number":["NIH R21 EB009133"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000888","name":"W. M. Keck Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000888","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Goverment of Russian Federation","award":["08-08"],"award-info":[{"award-number":["08-08"]}]},{"DOI":"10.13039\/501100003443","name":"Ministry of Education and Science of the Russian Federation","doi-asserted-by":"publisher","award":["3.2465.2017\/4.6"],"award-info":[{"award-number":["3.2465.2017\/4.6"]}],"id":[{"id":"10.13039\/501100003443","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Biomed. Eng."],"published-print":{"date-parts":[[2019,10]]},"DOI":"10.1109\/tbme.2019.2897029","type":"journal-article","created":{"date-parts":[[2019,2,1]],"date-time":"2019-02-01T21:05:47Z","timestamp":1549055147000},"page":"2848-2854","source":"Crossref","is-referenced-by-count":5,"title":["A Coaxial RF Applicator for Ultra-High Field Human MRI"],"prefix":"10.1109","volume":"66","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3024-0545","authenticated-orcid":false,"given":"Georgiy","family":"Solomakha","sequence":"first","affiliation":[]},{"given":"Anna","family":"Andreychenko","sequence":"additional","affiliation":[]},{"given":"Pierre-Francois van de","family":"Moortele","sequence":"additional","affiliation":[]},{"given":"H.","family":"Kroeze","sequence":"additional","affiliation":[]},{"given":"Alexander J.","family":"Raaijmakers","sequence":"additional","affiliation":[]},{"given":"F. E.","family":"Euwe","sequence":"additional","affiliation":[]},{"given":"J. J. W.","family":"Lagendijk","sequence":"additional","affiliation":[]},{"given":"P. R.","family":"Luijten","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5565-6889","authenticated-orcid":false,"given":"C. A. T. van den","family":"Berg","sequence":"additional","affiliation":[]}],"member":"263","reference":[{"key":"ref39","year":"2010","journal-title":"International Electrotechnical Commission International Standard Medical Equipment Particular Requirements for the Safety of Magnetic Resonance Equipment"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1002\/cmr.a.20219"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21120"},{"key":"ref32","first-page":"1676","article-title":"Calibration tools for RF shim at very high field with multiple element RF coils: From ultra fast local relative phase to absolute magnitude b1+ mapping","author":"moortele","year":"0","journal-title":"Proc ISMRM 19th Annu Meeting"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.1431"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1063\/1.1134852"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27095"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1007\/978-0-387-49648-1"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20177"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.3680"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24922"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2014.11.006"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24726"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26754"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22886"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25596"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/ICEAA.2017.8065600"},{"key":"ref17","article-title":"31-channel receive coil array combined with an 8-channel whole-brain dipole transmit array","author":"clement","year":"0","journal-title":"Proceedings of the 26th Annual Meeting of ISMRM"},{"key":"ref18","article-title":"Optimization and validation of dipole antenna geometry for body imaging at 10.5T","author":"steensma","year":"0","journal-title":"Proceedings of the 26th Annual Meeting of ISMRM"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25666"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.23107"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.3300"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24512"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.13131725"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.3338"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1007\/s10334-016-0559-y"},{"key":"ref5","first-page":"54","article-title":"Skin sodium measured with 23Na MRI at 7.0 T","volume":"28","author":"linz","year":"2014","journal-title":"NMR Biomed"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25822"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2010.02.056"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.3268"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24281"},{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.13130757"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1016\/0022-2364(85)90257-4"},{"key":"ref22","author":"pozar","year":"1993","journal-title":"Microwave Engineering"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1038\/nature07752"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.23069"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22262"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22817"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24496"}],"container-title":["IEEE Transactions on Biomedical Engineering"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/10\/8844138\/08632760.pdf?arnumber=8632760","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T20:54:20Z","timestamp":1657745660000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/8632760\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10]]},"references-count":39,"journal-issue":{"issue":"10"},"URL":"https:\/\/doi.org\/10.1109\/tbme.2019.2897029","relation":{},"ISSN":["0018-9294","1558-2531"],"issn-type":[{"value":"0018-9294","type":"print"},{"value":"1558-2531","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,10]]}}}