{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,15]],"date-time":"2025-12-15T19:48:42Z","timestamp":1765828122859,"version":"3.37.3"},"reference-count":56,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"3","license":[{"start":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T00:00:00Z","timestamp":1646092800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"},{"start":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T00:00:00Z","timestamp":1646092800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2022,3,1]],"date-time":"2022-03-01T00:00:00Z","timestamp":1646092800000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"funder":[{"DOI":"10.13039\/100007880","name":"Johns Hopkins University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007880","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Biomed. Eng."],"published-print":{"date-parts":[[2022,3]]},"DOI":"10.1109\/tbme.2021.3123887","type":"journal-article","created":{"date-parts":[[2021,10,29]],"date-time":"2021-10-29T19:21:47Z","timestamp":1635535307000},"page":"1264-1272","source":"Crossref","is-referenced-by-count":3,"title":["Parylene-C Microbore Tubing: A Simpler Shunt for Reducing Intraocular Pressure"],"prefix":"10.1109","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4739-6287","authenticated-orcid":false,"given":"Brett","family":"Collar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5740-7520","authenticated-orcid":false,"given":"Jay","family":"Shah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abigail","family":"Cox","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gabriel","family":"Simon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pedro","family":"Irazoqui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1093\/ajhp\/62.7.691"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2010.02455.x"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S32933"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.5041\/rmmj.10345"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.4103\/jovr.jovr_190_17"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.3109\/08820538.2014.959199"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2008.03.031"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1586\/17469899.2013.825461"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0183142"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1111\/ceo.12805"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2009.172"},{"year":"2017","key":"ref12","article-title":"Directions for use for the XEN Glaucoma treatment system"},{"year":"2017","key":"ref13","article-title":"iStent Inject trabecular micro-bypass system instructions for use"},{"year":"2018","key":"ref14","article-title":"Ex-PRESS Glaucoma filtration device"},{"year":"2018","key":"ref15","article-title":"Hydrus microstent instructions for use"},{"year":"2020","key":"ref16","article-title":"Microshunt  innfocus"},{"article-title":"NEI Research Initiatives: Audacious goals initiative","volume-title":"AGI for Regenerative Medicine","year":"2021","key":"ref17"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1111\/cts.12660"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-017-3895-3"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2017.05.004"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2011-300218"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.03.025"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.2147\/opth.s57217"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1038\/eye.2013.234"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1016\/j.tjo.2015.04.004"},{"key":"ref26","article-title":"Long term results of the Ex-PRESS P-200 miniature Glaucoma filtration device in primary and secondary Glaucoma","volume":"1","author":"Salvetat","year":"2018","journal-title":"World J. Surg. Surg. Res. - Ophthalmol."},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2019.04.034"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-019-0162-1"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2020.02.020"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4614-8348-9_17"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1016\/j.kjms.2011.10.016"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1007\/s12177-009-9018-6"},{"year":"2017","key":"ref33","article-title":"PARA TECH: Parylene medical device coatings for stents catheters atherectomy and occlusion devices"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.3928\/15428877-20110603-01"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-3921"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1016\/j.exer.2005.10.019"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1016\/S0014-4835(05)80131-9"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-200306000-00017"},{"year":"2020","key":"ref39","article-title":"iStent inject important safety information"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.4103\/0974-9233.56226"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-019-0157-y"},{"issue":"9","key":"ref42","first-page":"492","article-title":"A rabbit model for Glaucoma filtration surgery","volume":"59","author":"Nagar","year":"2018","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1155\/2016\/1056573"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1111\/ceo.13526"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1159\/000509135"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.17925\/eor.2019.13.1.27"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.1155\/2016\/2731856"},{"journal-title":"Mitosol","article-title":"EX-PRESS Glaucoma filtration device procedure","year":"2017","key":"ref48"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.1002\/0471238961"},{"key":"ref50","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2011.09.007"},{"key":"ref51","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2011.02356.x"},{"key":"ref52","doi-asserted-by":"publisher","DOI":"10.2147\/opth.s195457"},{"key":"ref53","doi-asserted-by":"publisher","DOI":"10.1093\/rb\/rbw005"},{"key":"ref54","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.117.2.233"},{"key":"ref55","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.cd002897.pub2"},{"key":"ref56","doi-asserted-by":"publisher","DOI":"10.1021\/acsami.5b01993"}],"container-title":["IEEE Transactions on Biomedical Engineering"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/10\/9716148\/09594677.pdf?arnumber=9594677","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,12]],"date-time":"2024-01-12T02:13:32Z","timestamp":1705025612000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/9594677\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3]]},"references-count":56,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.1109\/tbme.2021.3123887","relation":{},"ISSN":["0018-9294","1558-2531"],"issn-type":[{"type":"print","value":"0018-9294"},{"type":"electronic","value":"1558-2531"}],"subject":[],"published":{"date-parts":[[2022,3]]}}}