{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,14]],"date-time":"2025-06-14T19:28:19Z","timestamp":1749929299559,"version":"3.37.3"},"reference-count":37,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"4","license":[{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"},{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Biomed. Eng."],"published-print":{"date-parts":[[2024,4]]},"DOI":"10.1109\/tbme.2023.3329343","type":"journal-article","created":{"date-parts":[[2023,11,1]],"date-time":"2023-11-01T18:09:02Z","timestamp":1698862142000},"page":"1151-1160","source":"Crossref","is-referenced-by-count":1,"title":["A Novel Articulating Chip-on-Tip Endoscope for Dynamic Middle Ear Surgical Visualization"],"prefix":"10.1109","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8475-9628","authenticated-orcid":false,"given":"Brennan L.","family":"Moeller","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, University of Colorado Boulder, USA"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2247-4330","authenticated-orcid":false,"given":"Brian W.","family":"Herrmann","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology-Head and Neck Surgery, University of Colorado Anschutz, USA"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5901-8358","authenticated-orcid":false,"given":"Mark E.","family":"Rentschler","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Colorado Boulder, Boulder, CO, USA"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1109\/RBME.2018.2810605","article-title":"Review on otological robotic systems: Toward microrobot-assisted cholesteatoma surgery","volume":"11","author":"Dahroug","year":"2018","journal-title":"IEEE Rev. Biomed. Eng."},{"issue":"6","key":"ref2","doi-asserted-by":"crossref","DOI":"10.3390\/cancers13061398","article-title":"Current advances in robotics for head and neck surgeryA systematic review","volume":"13","author":"Boehm","year":"2021","journal-title":"Cancers"},{"issue":"3","key":"ref3","doi-asserted-by":"crossref","first-page":"1488","DOI":"10.1109\/LRA.2017.2668468","article-title":"Through the eustachian tube and beyond: A new miniature robotic endoscope to see into the middle ear","volume":"2","author":"Fichera","year":"2017","journal-title":"IEEE Robot. Automat. Lett."},{"issue":"1","key":"ref4","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-022-05969-3","article-title":"A miniature robotic steerable endoscope for maxillary sinus surgery called PliENT","volume":"12","author":"Legrand","year":"2022","journal-title":"Sci. Rep."},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.wjorl.2020.09.003"},{"issue":"7","key":"ref6","doi-asserted-by":"crossref","DOI":"10.3390\/act10070145","article-title":"Current trends and prospects in compliant continuum robots: A survey","volume":"10","author":"Li","year":"2021","journal-title":"Actuators"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1115\/dscc2012-movic2012-8536"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1097\/mao.0000000000003384"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-020-02518-9"},{"issue":"3","key":"ref10","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1364\/BOE.8.001441","article-title":"Endoscope field of view measurement","volume":"8","author":"Wang","year":"2017","journal-title":"Biomed. Opt. Exp."},{"year":"2001","key":"ref11","article-title":"FocESS 30 degree rigid nasal endoscope sinuscopes stryker"},{"article-title":"Surgery for cholesteatoma","year":"2022","author":"Australia","key":"ref12"},{"key":"ref13","article-title":"IMAGE1 S H3-Z KARL STORZ Endoskope"},{"year":"2020","key":"ref14","article-title":"Zeiss OPMI sensera - streamlining your performance"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1177\/000348949910800913"},{"issue":"10","key":"ref16","doi-asserted-by":"crossref","first-page":"1450","DOI":"10.1097\/MAO.0000000000001572","article-title":"Long-term complications and surgical failures after ossiculoplasty","volume":"38","author":"Cox","year":"2017","journal-title":"Otol. Neurotol."},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1055\/s-0039-1697989"},{"issue":"4","key":"ref18","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1016\/j.joto.2020.06.004","article-title":"Role of endoscopy in surgical management of cholesteatoma: A systematic review","volume":"15","author":"Verma","year":"2020","journal-title":"J. Otol."},{"year":"2020","key":"ref19","article-title":"Ear conditions"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-540-47671-9"},{"issue":"3","key":"ref21","article-title":"Impact of intraoperative findings on hearing in revision ear surgery","volume":"35","author":"Kosec","year":"2023","journal-title":"Iranian J. Otorhinolaryngol."},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-015-3679-5"},{"issue":"1","key":"ref23","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.joto.2019.11.004","article-title":"Endoscopic ear surgery","volume":"15","author":"Emre","year":"2020","journal-title":"J. Otol."},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1177\/014556130808700507"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1097\/01.mao.0000226305.43951.13"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.tacc.2020.02.001","article-title":"Evaluation of intubation and intensive care use of the new ambu aScopeTM 4 broncho and ambu aViewTM compared to a customary flexible endoscope a multicentre prospective, non-interventional study","volume":"31","author":"Kriege","year":"2020","journal-title":"Trends Anaesth. Crit. Care"},{"key":"ref27","doi-asserted-by":"crossref","first-page":"e717","DOI":"10.1016\/j.wneu.2019.03.247","article-title":"Breadth and depth: Three-dimensional endoscopic field of view: Two-dimensional versus three-dimensional endoscopic field of view","volume":"127","author":"Bickerton","year":"2019","journal-title":"World Neurosurgery"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1201\/b12887"},{"article-title":"Quick MTF: About resolution","year":"2008","author":"Kurtsev","key":"ref29"},{"article-title":"Quick MTF: Basic steps in calculating the MTF (SFR), and comparing it with the open-source tools SFRMAT3 and mitre SFR 1.4","year":"2011","author":"Kurtsev","key":"ref30"},{"year":"2015","key":"ref31","article-title":"Introduction to modulation transfer function edmund optics"},{"year":"2000","key":"ref32","article-title":"Modulation transfer function"},{"issue":"12","key":"ref33","first-page":"1","article-title":"Camera resolution and distortion: Advanced edge fitting","volume":"30","author":"Burns","year":"2018","journal-title":"Electron. Imag."},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1051\/matecconf\/201711901044"},{"volume-title":"Ergonomics and Design: A Reference Guide","year":"2007","author":"Openshaw","key":"ref35"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0079400"},{"year":"2013","key":"ref37","article-title":"How to make a needle insertion trainer"}],"container-title":["IEEE Transactions on Biomedical Engineering"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/10\/10477172\/10304323.pdf?arnumber=10304323","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,26]],"date-time":"2024-03-26T20:29:09Z","timestamp":1711484949000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10304323\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":37,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.1109\/tbme.2023.3329343","relation":{},"ISSN":["0018-9294","1558-2531"],"issn-type":[{"type":"print","value":"0018-9294"},{"type":"electronic","value":"1558-2531"}],"subject":[],"published":{"date-parts":[[2024,4]]}}}