{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T10:00:07Z","timestamp":1740132007450,"version":"3.37.3"},"reference-count":33,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"8","license":[{"start":{"date-parts":[[2013,4,1]],"date-time":"2013-04-01T00:00:00Z","timestamp":1364774400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["0925809"],"award-info":[{"award-number":["0925809"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,4]]},"abstract":"<jats:p>The stator turn-to-turn short circuit is an important type of fault in automotive claw-pole generators. In a typical vehicle electric power system, the built-in rectifier of the generator makes it difficult to access the ac current or voltage information, rendering conventional sequence-component-based fault-detection methods useless. To detect such fault using only the available sensor information, a dynamic model of the claw-pole generator with stator turn faults is derived in this paper to analyze how the fault would interact with the connected battery and the static full-bridge rectifier and how it would affect the generator's output voltage and current. It is found that, in the rectified generator output current, the harmonic at one-third of the rectifier ripple frequency is a robust signature of the stator turn fault. The performance of the stator turn-fault detector is demonstrated by extensive experimental results. Although the fault detector is originally proposed for claw-pole generators, it is also applicable to most polyphase ac generators with a dc-link rectifier.<\/jats:p>","DOI":"10.1109\/tie.2012.2205353","type":"journal-article","created":{"date-parts":[[2012,6,20]],"date-time":"2012-06-20T15:33:48Z","timestamp":1340206428000},"page":"3462-3471","source":"Crossref","is-referenced-by-count":17,"title":["Using Only the DC Current Information to Detect Stator Turn Faults in Automotive Claw-Pole Generators"],"prefix":"10.1109","volume":"60","author":[{"given":"Siwei","family":"Cheng","sequence":"first","affiliation":[]},{"given":"Thomas","family":"Habetler","sequence":"additional","affiliation":[]}],"member":"263","reference":[{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2011.2159691"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2009.2036643"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1109\/59.898088"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1109\/60.124547"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2064276"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2066538"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2062480"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2072895"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2009.2012468"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2009.2013557"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2009.2018905"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2008.926773"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2008.921380"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2009.2027198"},{"key":"ref28","article-title":"A practical approach for belt slip detection in automotive electric power generation and storage system","author":"zhang","year":"2010","journal-title":"Proc IEEE Aerosp Conf"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2068533"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1109\/TR.2009.2020484"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2010.2090839"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2053337"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/ICPHM.2011.6024315"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2054054"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2081955"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2087296"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1109\/28.464536"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2089937"},{"key":"ref1","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1109\/TIA.1985.349532","article-title":"Report of large motor reliability survey of industrial and commercial installations, Part I","volume":"ia 21","author":"o'donnell","year":"1985","journal-title":"IEEE Trans Ind Appl"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2004.834012"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2004.826432"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1109\/IECEC.1996.553407"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1109\/ACC.2007.4282836"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1115\/IMECE2006-14504"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1109\/DEMPED.2011.6063611"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1109\/DEMPED.2011.6063686"}],"container-title":["Industrial Electronics, IEEE Transactions on"],"original-title":[],"link":[{"URL":"http:\/\/ieeexplore.ieee.org\/iel5\/41\/6497104\/06221979.pdf?arnumber=6221979","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/xplorestaging.ieee.org\/ielx5\/41\/6497104\/06221979.pdf?arnumber=6221979","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,29]],"date-time":"2021-11-29T15:45:39Z","timestamp":1638200739000},"score":1,"resource":{"primary":{"URL":"http:\/\/ieeexplore.ieee.org\/document\/6221979\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,4]]},"references-count":33,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2013,4]]}},"URL":"https:\/\/doi.org\/10.1109\/tie.2012.2205353","relation":{},"ISSN":["0278-0046"],"issn-type":[{"type":"print","value":"0278-0046"}],"subject":[],"published":{"date-parts":[[2013,4]]}}}