{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T12:35:33Z","timestamp":1780317333405,"version":"3.54.1"},"reference-count":47,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"8","license":[{"start":{"date-parts":[[2021,8,1]],"date-time":"2021-08-01T00:00:00Z","timestamp":1627776000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"},{"start":{"date-parts":[[2021,8,1]],"date-time":"2021-08-01T00:00:00Z","timestamp":1627776000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2021,8,1]],"date-time":"2021-08-01T00:00:00Z","timestamp":1627776000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"funder":[{"name":"FCT"},{"DOI":"10.13039\/501100006111","name":"Minist\u00e9rio da Ci\u00eancia, Tecnologia e Ensino Superior","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100006111","id-type":"DOI","asserted-by":"publisher"}]},{"name":"EU funds","award":["UIDB\/EEA\/50008\/2020"],"award-info":[{"award-number":["UIDB\/EEA\/50008\/2020"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Ind. Electron."],"published-print":{"date-parts":[[2021,8]]},"DOI":"10.1109\/tie.2020.3003626","type":"journal-article","created":{"date-parts":[[2020,6,25]],"date-time":"2020-06-25T20:07:45Z","timestamp":1593115665000},"page":"7485-7495","source":"Crossref","is-referenced-by-count":27,"title":["Detection of Turn-to-Turn Faults in the Stator and Rotor of Synchronous Machines During Startup"],"prefix":"10.1109","volume":"68","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3035-7129","authenticated-orcid":false,"given":"Saeed","family":"Afrandideh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5442-4878","authenticated-orcid":false,"given":"Farhad","family":"Haghjoo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9651-8925","authenticated-orcid":false,"given":"Sergio","family":"Cruz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mostafa","family":"Eshaghi Milasi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"263","reference":[{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1049\/iet-rpg.2015.0013"},{"key":"ref38","year":"2006","journal-title":"IEEE Guide for Control of Hydroelectric Power Plants"},{"key":"ref33","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1109\/TEC.2011.2169264","article-title":"Steady-state calculation and online monitoring of interturn short circuit of field windings in synchronous machines","volume":"27","author":"hao","year":"2011","journal-title":"IEEE Trans Energy Convers"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2017.2745408"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2018.2861860"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2014.2339300"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1049\/iet-epa.2017.0118"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2017.2741503"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1109\/MIAS.2012.2215644"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1109\/TPAS.1971.293048"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2013.2259777"},{"key":"ref40","first-page":"1","article-title":"Modeling and simulation of the startup of a pumped storage power plant unit","author":"karaagac","year":"2009","journal-title":"Proc Int Conf Power Syst Transients"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/IEMDC.2011.5994623"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2012.2188138"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2018.2879686"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/28.952496"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2017.2688973"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2016.2535959"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/TMAG.2014.2318207"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1016\/j.matcom.2018.04.012"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2012.02.012"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1109\/60.326478"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2012.2216270"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1109\/TMAG.2016.2514406"},{"key":"ref3","volume":"21","author":"stone","year":"2004","journal-title":"Electrical Insulation for Rotating Machines Design Evaluation Aging Testing and Repair"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.4236\/jemaa.2009.13028"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2016.2521422"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1109\/APPEEC.2011.5748614"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2018.2837389"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.3390\/en11102524"},{"key":"ref2","volume":"38","author":"klempner","year":"2011","journal-title":"Handbook of Large Turbo-Generator Operation and Maintenance"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2018.2860128"},{"key":"ref1","year":"0"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2018.2870265"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2015.2402641"},{"key":"ref45","first-page":"14","article-title":"A new method for modeling and analyzing the increments of leakage flux in power transformer in inter-turn fault condition","author":"hajiaghasi","year":"2013","journal-title":"Proc 28th Int Power Syst Conf"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2014.2370931"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.1109\/TITS.2019.2897583"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1049\/iet-epa.2009.0264"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1109\/PSPC.2015.7094924"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2012.2227808"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2002.1009480"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1109\/JSEN.2014.2319175"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2006.881620"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2009.2018905"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1049\/iet-gtd.2015.0738"},{"key":"ref25","first-page":"161","article-title":"Stator turn-to-turn fault detection of synchronous generator using total harmonic distortion (THD) analyzing of magnetic flux linkage","volume":"37","author":"yaghobi","year":"2013","journal-title":"IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF ELECTRICAL ENGINEERING"}],"container-title":["IEEE Transactions on Industrial Electronics"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/41\/9420632\/09126264.pdf?arnumber=9126264","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,10]],"date-time":"2022-05-10T14:49:34Z","timestamp":1652194174000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/9126264\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8]]},"references-count":47,"journal-issue":{"issue":"8"},"URL":"https:\/\/doi.org\/10.1109\/tie.2020.3003626","relation":{},"ISSN":["0278-0046","1557-9948"],"issn-type":[{"value":"0278-0046","type":"print"},{"value":"1557-9948","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,8]]}}}