{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,21]],"date-time":"2026-06-21T00:21:43Z","timestamp":1782001303648,"version":"3.54.5"},"reference-count":28,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"12","license":[{"start":{"date-parts":[[2013,12,1]],"date-time":"2013-12-01T00:00:00Z","timestamp":1385856000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Instrum. Meas."],"published-print":{"date-parts":[[2013,12]]},"DOI":"10.1109\/tim.2013.2272202","type":"journal-article","created":{"date-parts":[[2013,7,24]],"date-time":"2013-07-24T22:51:52Z","timestamp":1374706312000},"page":"3243-3250","source":"Crossref","is-referenced-by-count":15,"title":["Optimization of a Low-Cost Force Sensor for Spinal Orthosis Applications"],"prefix":"10.1109","volume":"62","author":[{"given":"Katherine R.","family":"Evans","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edmond","family":"Lou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gary","family":"Faulkner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"263","reference":[{"key":"ref10","first-page":"1","article-title":"Development of instrumented spinal brace for measuring compliance and skin microclimate in the conservative treatment of adolescent idiopathic scoliosis","author":"nicholson","year":"2002","journal-title":"Proc BSS Silver Jubilee Meeting"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-200201150-00018"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/86.593280"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/ICMECH.2009.4957201"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/ROBOT.2004.1307240"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1177\/107110079801901004"},{"key":"ref16","first-page":"636","article-title":"Experimental evaluation of two commercial force sensors for applications in biomechanics and motor control","author":"vecchi","year":"2000","journal-title":"Proc 5th Annu Conf IFESS"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/MIM.2010.5399212"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"8452","DOI":"10.3390\/s100908452","article-title":"A high-sensitivity hydraulic load cell for small kitchen appliances","volume":"10","author":"pa?nik","year":"2010","journal-title":"SENSORS"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.3390\/s6070697"},{"key":"ref28","first-page":"191","author":"kalpakjian","year":"2010","journal-title":"Manufacturing Engineering and Technology"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-009-0884-9"},{"key":"ref27","year":"1979","journal-title":"ANSI\/ISA Process Instrumentation Terminology"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.3109\/09593985.2010.503989"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1097\/00007632-199902150-00010"},{"key":"ref5","first-page":"346","article-title":"Brace wear characteristics during the first 6 months for the treatment of scoliosis","volume":"176","author":"lou","year":"2012","journal-title":"Studies Health Technol Inf"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000197412.70050.0d"},{"key":"ref7","first-page":"294","article-title":"Preliminary validation of curve progression model for brace treatment","volume":"140","author":"lou","year":"2008","journal-title":"Studies Health Technol Inf"},{"key":"ref2","first-page":"529","volume":"54","author":"parent","year":"2005","journal-title":"Instructional Course Lectures"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1097\/01.BRS.0000085098.69522.52"},{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1186\/1748-7161-1-2"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2002.807792"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1007\/s11517-010-0575-4"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2010.10.016"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1007\/BF02430952"},{"key":"ref23","first-page":"81","article-title":"A method for the measurement of the boston brace biomechanical action on scoliotic deformities","author":"cote","year":"1992","journal-title":"Proc Int Symp SDM"},{"key":"ref26","first-page":"569","article-title":"Expanding applications and opportunities with polyjet rapid prototyping technology","author":"sagi","year":"2007","journal-title":"Proc 3rd Int Conf Adv Res Virtual Rapid Prototyping"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1016\/j.medengphy.2011.12.022"}],"container-title":["IEEE Transactions on Instrumentation and Measurement"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/19\/6650212\/06567924.pdf?arnumber=6567924","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,29]],"date-time":"2021-11-29T20:47:26Z","timestamp":1638218846000},"score":1,"resource":{"primary":{"URL":"http:\/\/ieeexplore.ieee.org\/document\/6567924\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,12]]},"references-count":28,"journal-issue":{"issue":"12"},"URL":"https:\/\/doi.org\/10.1109\/tim.2013.2272202","relation":{},"ISSN":["0018-9456","1557-9662"],"issn-type":[{"value":"0018-9456","type":"print"},{"value":"1557-9662","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,12]]}}}