{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T13:40:38Z","timestamp":1758894038151},"reference-count":5,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"3","license":[{"start":{"date-parts":[[2014,5,1]],"date-time":"2014-05-01T00:00:00Z","timestamp":1398902400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/IEEE.html"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Smart Grid"],"published-print":{"date-parts":[[2014,5]]},"DOI":"10.1109\/tsg.2013.2277940","type":"journal-article","created":{"date-parts":[[2013,8,20]],"date-time":"2013-08-20T18:02:04Z","timestamp":1377021724000},"page":"1159-1164","source":"Crossref","is-referenced-by-count":36,"title":["Design and Performance Testing of a Multivendor IEC61850\u20139-2 Process Bus Based Protection Scheme"],"prefix":"10.1109","volume":"5","author":[{"given":"Li","family":"Yang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter A.","family":"Crossley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"An","family":"Wen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ray","family":"Chatfield","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Wright","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref4","first-page":"1","article-title":"Performance assessment of a IEC 61850?9-2 based protection scheme for a transmission substation","author":"yang","year":"2011","journal-title":"Proc 2nd Eur Conf Exhib Innovative Smart Grid Technologies (ISGT-EUROPE 2011)"},{"key":"ref3","first-page":"534","article-title":"Design and performance evaluation for a protection system utilising","author":"peter","year":"2011","journal-title":"IEC 61850?9-2 Process bus Int Conf on Advanced Power Syst Automation Protection 2011"},{"key":"ref5","first-page":"5b","article-title":"Performance assessment of an IEC 61850-9-2 based protection scheme for the mesh corner of a 400 kV transmission substation","author":"peter","year":"2012","journal-title":"Proc Cigre Session 41"},{"key":"ref2","year":"0","journal-title":"Implementation Guideline for Digital Interface to Instrument Transformers Using IEC 61850?9-2"},{"key":"ref1","year":"2005","journal-title":"International Standard IEC 61850 Communication Networks and Systems in Substations"}],"container-title":["IEEE Transactions on Smart Grid"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/5165411\/6800037\/06583245.pdf?arnumber=6583245","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,12]],"date-time":"2022-01-12T16:18:40Z","timestamp":1642004320000},"score":1,"resource":{"primary":{"URL":"http:\/\/ieeexplore.ieee.org\/document\/6583245\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5]]},"references-count":5,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.1109\/tsg.2013.2277940","relation":{},"ISSN":["1949-3053","1949-3061"],"issn-type":[{"value":"1949-3053","type":"print"},{"value":"1949-3061","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,5]]}}}