{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T15:45:37Z","timestamp":1773330337509,"version":"3.50.1"},"reference-count":51,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"5","license":[{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/USG.html"},{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"am","delay-in-days":0,"URL":"https:\/\/ieeexplore.ieee.org\/Xplorehelp\/downloads\/license-information\/USG.html"},{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"}],"funder":[{"DOI":"10.13039\/100011661","name":"Pacific Northwest National Laboratory","doi-asserted-by":"publisher","award":["DE-AC05-76RL01830"],"award-info":[{"award-number":["DE-AC05-76RL01830"]}],"id":[{"id":"10.13039\/100011661","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Smart Grid"],"published-print":{"date-parts":[[2018,9]]},"DOI":"10.1109\/tsg.2017.2669642","type":"journal-article","created":{"date-parts":[[2017,2,16]],"date-time":"2017-02-16T19:12:28Z","timestamp":1487272348000},"page":"4755-4764","source":"Crossref","is-referenced-by-count":65,"title":["Enabling Resiliency Operations Across Multiple Microgrids With Grid Friendly Appliance Controllers"],"prefix":"10.1109","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1749-5014","authenticated-orcid":false,"given":"Kevin P.","family":"Schneider","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1960-9663","authenticated-orcid":false,"given":"Francis K.","family":"Tuffner","sequence":"additional","affiliation":[]},{"given":"Marcelo A.","family":"Elizondo","sequence":"additional","affiliation":[]},{"given":"Chen-Ching","family":"Liu","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0945-9024","authenticated-orcid":false,"given":"Yin","family":"Xu","sequence":"additional","affiliation":[]},{"given":"Scott","family":"Backhaus","sequence":"additional","affiliation":[]},{"given":"Dan","family":"Ton","sequence":"additional","affiliation":[]}],"member":"263","reference":[{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.2172\/1375380"},{"key":"ref38","article-title":"Pacific Northwest smart grid demonstration project 2011 annual report","author":"melton","year":"2011"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1109\/POWERCON.2014.6993833"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2014.2362191"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1109\/CICED.2012.6508530"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2010.2041139"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.2172\/926122"},{"key":"ref36","article-title":"Grid regulation services for energy storage devices based on grid frequency","author":"pratt","year":"2013"},{"key":"ref35","first-page":"647","article-title":"Design considerations for frequency responsive grid friendly&#x2122; appliances","author":"lu","year":"2006","journal-title":"Proc IEEE PES Transm Distrib Conf Exhibit"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2015.2397318"},{"key":"ref28","year":"0"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1109\/ICNSC.2011.5874892"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2012.2208658"},{"key":"ref2","article-title":"Smart cities preliminary report","year":"2015"},{"key":"ref1","article-title":"Report to the president technology and the future of cities","year":"2016"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.2172\/6584645"},{"key":"ref22","first-page":"142","article-title":"Diversity: A new problem in feeder pick-up","author":"hartay","year":"1952","journal-title":"Elect Light Power"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1109\/JPROC.2011.2114630"},{"key":"ref24","first-page":"52","article-title":"Normal relay settings handle cold load","author":"smithley","year":"1959","journal-title":"Elect World"},{"key":"ref23","first-page":"101","article-title":"A new approach to cold load restoration","author":"ramsaur","year":"1952","journal-title":"Elect World"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1109\/JPHOTOV.2013.2280953"},{"key":"ref25","author":"kundur","year":"1994","journal-title":"Power System Stability and Control"},{"key":"ref50","article-title":"Utility assessment report for SPIDERS phase 1: Joint base Pearl Harbor Hickam (Rev 2.0)","author":"schneider","year":"2013"},{"key":"ref51","article-title":"Utility assessment report for SPIDERS phase 2: Ft. Carson (Rev 1.0)","author":"barr","year":"2015"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1109\/ISGT-LA.2015.7381268"},{"key":"ref11","first-page":"1","article-title":"Knowledge and decisions for smart cities initiatives","author":"arduin","year":"2016","journal-title":"Proc Int Conf Comput Syst Ind Informat"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.1109\/PESGM.2015.7286424"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2014.2344684"},{"key":"ref13","year":"2013","journal-title":"Microgrid Effects and Opportunities for Utilities"},{"key":"ref14","article-title":"SPIDERS project: Fort Carson preliminary design summary","author":"stamp","year":"2012"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/PESGM.2012.6345525"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2010.2051819"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2013.2295514"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1016\/j.brat.2007.04.013"},{"key":"ref19","article-title":"Economic impact of Hurricane Sandy potential economic activity lost and gained in New Jersey and New York","year":"2013"},{"key":"ref4","article-title":"Global innovations: International case studies on smart cities","year":"2013"},{"key":"ref3","article-title":"Smart cities: Background paper","year":"2013"},{"key":"ref6","article-title":"Research report on smart city","year":"2015"},{"key":"ref5","article-title":"Sustainable Chicago year two progress report, city of Chicago","year":"2014"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/PES.2011.6039045"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2015.2469260"},{"key":"ref49","article-title":"How to size a genset: Proper generator set sizing requires analysis of parameters and loads","year":"2007","journal-title":"White Paper"},{"key":"ref9","author":"hirose","year":"2013","journal-title":"The Sendai Microgrid Operational Experience in the Aftermath of the Tohoku Earthquake A Case Study"},{"key":"ref46","year":"2017","journal-title":"Turbine-Governor Models Standard Dynamic Turbine-Governor Systems in NEPLAN Power System Analysis Tool NEPLAN V555"},{"key":"ref45","year":"2017","journal-title":"Cummins Prime Power Generator Data Sheets"},{"key":"ref48","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/492320"},{"key":"ref47","article-title":"Grid friendly \n$^{TM}$\n chip data sheet and users&#x2019; manual","author":"hammerstrom","year":"2008"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2015.2389712"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2015.2494867"},{"key":"ref44","author":"fitzgerald","year":"2003","journal-title":"Umans Electric machinery"},{"key":"ref43","year":"2017","journal-title":"IEEE PES Distribution Systems Analysis Subcommittee Radial Test Feeders"}],"container-title":["IEEE Transactions on Smart Grid"],"original-title":[],"link":[{"URL":"https:\/\/ieeexplore.ieee.org\/ielaam\/5165411\/8443168\/7857787-aam.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/5165411\/8443168\/07857787.pdf?arnumber=7857787","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,8]],"date-time":"2022-04-08T18:52:40Z","timestamp":1649443960000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/7857787\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9]]},"references-count":51,"journal-issue":{"issue":"5"},"URL":"https:\/\/doi.org\/10.1109\/tsg.2017.2669642","relation":{},"ISSN":["1949-3053","1949-3061"],"issn-type":[{"value":"1949-3053","type":"print"},{"value":"1949-3061","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9]]}}}