{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T00:35:17Z","timestamp":1787013317616,"version":"build-2736575974"},"reference-count":43,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","issue":"1","license":[{"start":{"date-parts":[[2020,1,1]],"date-time":"2020-01-01T00:00:00Z","timestamp":1577836800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/legalcode"}],"funder":[{"DOI":"10.13039\/501100003246","name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek","doi-asserted-by":"publisher","award":["13525"],"award-info":[{"award-number":["13525"]}],"id":[{"id":"10.13039\/501100003246","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100007423","name":"Duchenne Parent Project","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100007423","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Hankamp Rehab"},{"name":"Spieren voor Spieren"},{"DOI":"10.13039\/501100019679","name":"Tropical Marine Science Institute, National University of Singapore","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100019679","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Festo"},{"name":"Pontes Medical"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Neural Syst. Rehabil. Eng."],"published-print":{"date-parts":[[2020,1]]},"DOI":"10.1109\/tnsre.2019.2952470","type":"journal-article","created":{"date-parts":[[2020,1,8]],"date-time":"2020-01-08T16:24:38Z","timestamp":1578500678000},"page":"258-266","source":"Crossref","is-referenced-by-count":38,"title":["A Case Study With Symbihand: An sEMG-Controlled Electrohydraulic Hand Orthosis for Individuals With Duchenne Muscular Dystrophy"],"prefix":"10.1109","volume":"28","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7251-5941","authenticated-orcid":false,"given":"Ronald A.","family":"Bos","sequence":"first","affiliation":[{"name":"Department of Biomechanical Engineering, Delft University of Technology, Delft, CD, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6965-0242","authenticated-orcid":false,"given":"Kostas","family":"Nizamis","sequence":"additional","affiliation":[{"name":"Department of Biomechanical Engineering, University of Twente, Enschede, NB, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5091-1724","authenticated-orcid":false,"given":"Bart F. J. M.","family":"Koopman","sequence":"additional","affiliation":[{"name":"Department of Biomechanical Engineering, University of Twente, Enschede, NB, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2770-0539","authenticated-orcid":false,"given":"Just L.","family":"Herder","sequence":"additional","affiliation":[{"name":"Department of Precision and Microsystems Engineering, Delft University of Technology, Delft, CD, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0930-6535","authenticated-orcid":false,"given":"Massimo","family":"Sartori","sequence":"additional","affiliation":[{"name":"Department of Biomechanical Engineering, University of Twente, Enschede, NB, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dick H.","family":"Plettenburg","sequence":"additional","affiliation":[{"name":"Department of Biomechanical Engineering, Delft University of Technology, Delft, CD, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"263","reference":[{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1109\/TMRB.2019.2895791"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/aae26b"},{"key":"ref33","first-page":"139","article-title":"Analysis of the reliability and reproducibility of goniometry compared to hand photogrammetry","volume":"20","author":"de carvalho","year":"2012","journal-title":"Acta Ortop&#x00E9 dica Brasileira"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1109\/EURCON.2005.1629944"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1177\/027836499701600302"},{"key":"ref30","first-page":"71","article-title":"Evaluation of cable vs. hydraulic transmission of forces for body-powered arm prostheses","author":"le blanc","year":"1985","journal-title":"Proc RESNA 8th Ann Conf"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-04255-x"},{"key":"ref36","article-title":"Human grasping database for activities of daily living with depth, color and kinematic data streams","volume":"5","author":"saudabayev","year":"2018","journal-title":"Data Science Journal"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1186\/1743-0003-11-91"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1109\/TOH.2013.6"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.bbadis.2006.06.009"},{"key":"ref40","first-page":"82","article-title":"Instrumented objects for quantitative evaluation of hand grasp","volume":"34","author":"memberg","year":"1997","journal-title":"J Rehabil Res Develop"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1016\/0003-9993(93)90004-T"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1080\/09638288.2017.1347721"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.nmd.2016.04.005"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1016\/S1474-4422(09)70272-8"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2012.2198821"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1002\/9781119082934.ch20"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-016-0168-z"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2016.2530762"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-017-0282-6","article-title":"Comparison between sEMG and force as control interfaces to support planar arm movements in adults with Duchenne: A feasibility study","volume":"14","author":"lobo-prat","year":"2017","journal-title":"J Neuroeng Rehabil"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1111\/dmcn.12213"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1097\/PEP.0b013e3181cbfbf6"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.5535\/arm.2012.36.1.22"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.2340\/16501977-1898"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1080\/13638490400010191"},{"key":"ref29","author":"bos","year":"2018","journal-title":"SymbiHand DMD case study"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/S1474-4422(09)70271-6"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1111\/dmcn.14248"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1080\/09638288.2016.1196398"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1186\/s13023-017-0631-3"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.nmd.2007.11.004"},{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1007\/s00415-014-7316-9"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/ICORR.2015.7281175"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2010.2079334"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1109\/ICRA.2015.7139597"},{"key":"ref42","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1080\/03091900110065951","article-title":"An instrumented object for evaluation of lateral hand grasp during functional tasks","volume":"25","author":"inmann","year":"2001","journal-title":"Journal of Medical Engineering & Technology"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.3389\/fnins.2017.00547"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1109\/86.681187"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-018-0391-x"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1109\/BIOROB.2018.8487196"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2018.2866956"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1109\/TMRB.2019.2912453"}],"container-title":["IEEE Transactions on Neural Systems and Rehabilitation Engineering"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/7333\/8952818\/08926408.pdf?arnumber=8926408","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,15]],"date-time":"2024-01-15T16:32:58Z","timestamp":1705336378000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/8926408\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1]]},"references-count":43,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.1109\/tnsre.2019.2952470","relation":{},"ISSN":["1534-4320","1558-0210"],"issn-type":[{"value":"1534-4320","type":"print"},{"value":"1558-0210","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1]]}}}