{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T08:46:32Z","timestamp":1794905192942,"version":"4.9.1"},"reference-count":53,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R01HD081525"],"award-info":[{"award-number":["R01HD081525"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["5R01HD094861"],"award-info":[{"award-number":["5R01HD094861"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Trans. Neural Syst. Rehabil. Eng."],"published-print":{"date-parts":[[2023]]},"DOI":"10.1109\/tnsre.2022.3221558","type":"journal-article","created":{"date-parts":[[2022,11,10]],"date-time":"2022-11-10T15:38:03Z","timestamp":1668094683000},"page":"271-281","source":"Crossref","is-referenced-by-count":43,"title":["User Performance With a Transradial Multi-Articulating Hand Prosthesis During Pattern Recognition and Direct Control Home Use"],"prefix":"10.1109","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6431-0329","authenticated-orcid":false,"given":"Ann M.","family":"Simon","sequence":"first","affiliation":[{"name":"Shirley Ryan AbilityLab, Center for Bionic Medicine, Chicago, IL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristi L.","family":"Turner","sequence":"additional","affiliation":[{"name":"Shirley Ryan AbilityLab, Center for Bionic Medicine, Chicago, IL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7271-6214","authenticated-orcid":false,"given":"Laura A.","family":"Miller","sequence":"additional","affiliation":[{"name":"Shirley Ryan AbilityLab, Center for Bionic Medicine, Chicago, IL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin K.","family":"Potter","sequence":"additional","affiliation":[{"name":"Department of Surgery, Walter Reed National Military Medical Center, Uniformed Services University, Bethesda, MD, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark D.","family":"Beachler","sequence":"additional","affiliation":[{"name":"Department of Rehabilitation, Orthotic and Prosthetic Service, Walter Reed National Military Medical Center, Bethesda, MD, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregory A.","family":"Dumanian","sequence":"additional","affiliation":[{"name":"Division of Plastic Surgery, Northwestern Feinberg School of Medicine, Chicago, IL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1705-0050","authenticated-orcid":false,"given":"Levi J.","family":"Hargrove","sequence":"additional","affiliation":[{"name":"Shirley Ryan AbilityLab, Center for Bionic Medicine, Chicago, IL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Todd A.","family":"Kuiken","sequence":"additional","affiliation":[{"name":"Shirley Ryan AbilityLab, Center for Bionic Medicine, Chicago, IL, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"263","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1097\/00007611-200208000-00018"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1109\/TOH.2014.2326871"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1109\/TOH.2014.2326867"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1682\/jrrd.2011.10.0188"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1615\/critrevbiomedeng.2013007887"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.1960"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2019.101588"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620x.47b3.411"},{"key":"ref9","first-page":"207","article-title":"Control of powered upper extremity prostheses","volume-title":"Functional Restoration of Adults and Children With Upper Extremity Amputation","author":"Williams","year":"2004"},{"issue":"30","key":"ref10","first-page":"8","article-title":"Pattern-recognition arm prosthesis: A historical perspective. A final report","volume-title":"Bull. Prosthet. Res.","volume":"10","author":"Wirta","year":"1978"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1007\/BF00286094"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/10.204774"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2003.813539"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2009.2039590"},{"key":"ref15","doi-asserted-by":"publisher","DOI":"10.1152\/jn.00178.2007"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2011.2108667"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2008.2005485"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2009.2039619"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC44109.2020.9176603"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2020.3016909"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-14386-w"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1109\/JTEHM.2016.2616123"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-018-0361-3"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0203987"},{"key":"ref25","volume-title":"Complete Control","year":"2019"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1097\/jpo.0000000000000058"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1177\/0309364617728117"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.2340\/jrm.v53.807"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1109\/JTEHM.2018.2811458"},{"key":"ref30","volume-title":"I-Limb Ultra Revolution","year":"2022"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1097\/jpo.0b013e3182515437"},{"key":"ref32","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC.2012.6346318"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2009.116"},{"key":"ref34","volume-title":"Pattern Classification","author":"Duda","year":"2000"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1682\/jrrd.2010.09.0177"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2013.2247421"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1097\/jpo.0b013e3181a1d2dc"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1053\/apmr.2002.32737"},{"issue":"6","key":"ref39","first-page":"311","article-title":"An objective and standardized test of hand function","volume":"50","author":"Jebsen","year":"1969","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.1080\/16501970410024280"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.2340\/16501977-0361"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.5014\/ajot.39.6.386"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1016\/j.apmr.2012.10.004"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.3109\/03093641003767207"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0219333"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2015.2398112"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.1007\/bf02443970"},{"key":"ref48","first-page":"1","article-title":"Prosthesis-guided training increases functional wear time and improves tolerance to malfunctioning inputs of pattern recognition\u2013controlled prostheses","volume-title":"Proc. Myoelectr. Control Symp. (MEC)","author":"Simon"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-019-0480-5"},{"key":"ref50","first-page":"1","article-title":"Prosthesis-guided training for practical use of pattern recognition control of prostheses","volume-title":"Proc. Myoelectr. Symp. (MEC)","author":"Lock"},{"key":"ref51","first-page":"1","article-title":"Data quality assessment tool to improve upper limb myoelectric prosthesis control","volume-title":"Proc. Amer. Orthotics Prosthetics (AOPA)","author":"Wright"},{"key":"ref52","first-page":"1","article-title":"Data logging during pattern recognition calibration as a remote diagnositc tool","volume-title":"Proc. MEC Symp.","author":"Miller"},{"key":"ref53","doi-asserted-by":"publisher","DOI":"10.2340\/16501977-1827"}],"container-title":["IEEE Transactions on Neural Systems and Rehabilitation Engineering"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/7333\/10031624\/09946002.pdf?arnumber=9946002","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,31]],"date-time":"2024-01-31T21:42:12Z","timestamp":1706737332000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/9946002\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"references-count":53,"URL":"https:\/\/doi.org\/10.1109\/tnsre.2022.3221558","relation":{"has-preprint":[{"id-type":"doi","id":"10.36227\/techrxiv.19859281","asserted-by":"object"},{"id-type":"doi","id":"10.36227\/techrxiv.19859281.v2","asserted-by":"object"},{"id-type":"doi","id":"10.36227\/techrxiv.19859281.v1","asserted-by":"object"}]},"ISSN":["1534-4320","1558-0210"],"issn-type":[{"value":"1534-4320","type":"print"},{"value":"1558-0210","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023]]}}}