{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T14:38:28Z","timestamp":1773153508599,"version":"3.50.1"},"reference-count":25,"publisher":"Wiley","issue":"S4","license":[{"start":{"date-parts":[[2017,9,21]],"date-time":"2017-09-21T00:00:00Z","timestamp":1505952000000},"content-version":"vor","delay-in-days":20,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2017,9,1]],"date-time":"2017-09-01T00:00:00Z","timestamp":1504224000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["obgyn.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["BJOG"],"published-print":{"date-parts":[[2017,9]]},"abstract":"<jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>\n                      The\n                      <jats:styled-content style=\"fixed-case\">BD<\/jats:styled-content>\n                      Odon Device\u2122 is a new instrument for operative vaginal birth with potential for preventing maternal, fetal and newborn morbidity\/mortality during a complicated second stage of labour. The device is a plastic sleeve with an air chamber inflated around the baby's head which is gently pulled through the birth canal. The aim was to monitor changes in cerebral circulation during constriction of the neck to evaluate a risk of potential malposition of the device.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>Randomised prospective study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Population or sample<\/jats:title>\n                    <jats:p>Twelve newborn piglets.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      The anaesthetised piglets were exposed to hypoxia until base excess was \u201320\u00a0mmol\/l and\/or mean arterial blood pressure had decreased to 20\u00a0mmHg. At reoxygenation, an air chamber was inflated around the neck to 300\u00a0mmHg and the piglets randomised into three groups: 10 (\n                      <jats:italic>n<\/jats:italic>\n                      \u00a0=\u00a05), 5 (\n                      <jats:italic>n<\/jats:italic>\n                      \u00a0=\u00a05) or 2 (\n                      <jats:italic>n<\/jats:italic>\n                      \u00a0=\u00a02) minutes\u2019 occlusion. Cerebral perfusion was evaluated with transcranial contrast\u2010enhanced ultrasound at four time\u2010points, and analysed in the carotid arteries, basal ganglia, cortex and whole brain. Statistical analysis used\n                      <jats:styled-content style=\"fixed-case\">ANOVA<\/jats:styled-content>\n                      , linear mixed model, Kruskal\u2013Wallis\n                      <jats:italic>H<\/jats:italic>\n                      \u2010test.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main outcome measures<\/jats:title>\n                    <jats:p>Perfusion parameters; peak intensity, time to peak intensity, upslope, mean transit time, area under the curve.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The haemodynamic response was comparable between groups. Perfusion parameters showed a slight increase at end hypoxia followed by a decrease during occlusion, especially in the cortex (\n                      <jats:italic>P\u00a0<\/jats:italic>\n                      =\u00a00.00\u20130.2). After deflation, perfusion returned towards baseline values.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Simulation of malposition of the Odon Device was performed using a newborn hypoxic piglet model. Considerable compression of the neck vessels was applied, with only a moderate decrease in perfusion and with restoration of haemodynamics\/cerebral perfusion after decompression.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Tweetable abstract<\/jats:title>\n                    <jats:p>Malposition of Odon Device\u2122 in a piglet model revealed a reversible decrease in cerebral perfusion during neck constriction.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1111\/1471-0528.14751","type":"journal-article","created":{"date-parts":[[2017,9,21]],"date-time":"2017-09-21T09:45:19Z","timestamp":1505987119000},"page":"26-34","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Assessment of cerebral perfusion with contrast\u2010enhanced ultrasound during constriction of the neck mimicking malposition of the\n                    <scp>BD<\/scp>\n                    Odon Device\u2122: a study in newborn piglets"],"prefix":"10.1111","volume":"124","author":[{"given":"C","family":"de Lange","sequence":"first","affiliation":[{"name":"Division of Radiology and Nuclear Medicine Paediatric Unit Oslo University Hospital Rikshospitalet Oslo Norway"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"O D","family":"Saugstad","sequence":"additional","affiliation":[{"name":"Department of Paediatric Research and Department of Surgical Research Oslo University Hospital Rikshospitalet Oslo Norway"},{"name":"University of Oslo Oslo Norway"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R","family":"Solberg","sequence":"additional","affiliation":[{"name":"Department of Paediatric Research and Department of Surgical Research Oslo University Hospital Rikshospitalet Oslo Norway"},{"name":"Department of Paediatrics Vestfold Hospital Trust T\u00f8nsberg Norway"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,9,21]]},"reference":[{"key":"e_1_2_6_2_1","unstructured":"New low\u2010cost instrument for assisted vaginal delivery World Health Organization[webpage].2013. [http:\/\/www.who.int\/reproductivehealth\/topics\/maternal_perinatal\/odon_device\/en\/] Accessed 10.05.2017."},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1186\/1742-4755-10-42"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1186\/1742-4755-10-33"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1203\/00006450-199412000-00003"},{"key":"e_1_2_6_6_1","first-page":"1","article-title":"A piglet model for detection of hypoxic\u2010ischemic brain injury with magnetic resonance imaging","author":"Munkeby BH","year":"2008","journal-title":"Acta Radiol"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1203\/00006450-199004000-00001"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1203\/00006450-199207000-00021"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1159\/000244220"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0150-9861(05)83159-1"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10406-004-0076-3"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10406-004-0086-1"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2006-927023"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-010-1965-6"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2463070652"},{"key":"e_1_2_6_16_1","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1097\/RLI.0b013e3182266431","article-title":"Cerebral perfusion in perinatal hypoxia and resuscitation assessed by transcranial contrast\u2010enhanced ultrasound and 3 T MRI in newborn pigs","volume":"46","author":"Lange C","year":"2011","journal-title":"Invest Radiol"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000053"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.7863\/ultra.15.02030"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2014.11.003"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpedsurg.2015.10.074"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-963413"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.10058"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1954.6.12.731"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/0378-3782(79)90022-7"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.20084"},{"key":"e_1_2_6_26_1","first-page":"551","article-title":"Comparison of cerebrocortical microvascular effects of different hypoxic\u2010ischemic insults in piglets: a laser\u2010speckle imaging study","volume":"65","author":"Domoki F","year":"2014","journal-title":"J Physiol Pharmacol"}],"container-title":["BJOG: An International Journal of Obstetrics &amp; Gynaecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2F1471-0528.14751","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/1471-0528.14751","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/full-xml\/10.1111\/1471-0528.14751","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/1471-0528.14751","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T08:49:11Z","timestamp":1772959751000},"score":1,"resource":{"primary":{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/10.1111\/1471-0528.14751"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9]]},"references-count":25,"journal-issue":{"issue":"S4","published-print":{"date-parts":[[2017,9]]}},"alternative-id":["10.1111\/1471-0528.14751"],"URL":"https:\/\/doi.org\/10.1111\/1471-0528.14751","archive":["Portico"],"relation":{},"ISSN":["1470-0328","1471-0528"],"issn-type":[{"value":"1470-0328","type":"print"},{"value":"1471-0528","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,9]]},"assertion":[{"value":"2017-06-25","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2017-09-21","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}