{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T14:44:05Z","timestamp":1740149045817,"version":"3.37.3"},"reference-count":12,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2015,4,1]],"date-time":"2015-04-01T00:00:00Z","timestamp":1427846400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100001026","name":"National Breast Cancer Foundation, Australia","doi-asserted-by":"crossref","award":["IF-12-02"],"award-info":[{"award-number":["IF-12-02"]}],"id":[{"id":"10.13039\/501100001026","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["J Med Imag Rad Onc"],"published-print":{"date-parts":[[2015,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>This study aims to evaluate the effectiveness of zooming in improving screen\u2010reader performance in reporting digital mammograms.<\/jats:p><\/jats:sec><jats:sec><jats:title>Method<\/jats:title><jats:p>Two experiments were conducted. In the first experiment, 5 readers were asked to report 59 two\u2010view bilateral mammograms retrospectively with zooming function turned off. The second session was similar to the first one except that zooming was enabled. The task of readers was to assess if the mammograms were normal or abnormal and rate the confidence levels for each of the lesion they detected. The reader performances were evaluated via case sensitivity, lesion sensitivity, specificity, receiver operating characteristics (<jats:styled-content style=\"fixed-case\">ROC<\/jats:styled-content>) area under the curve (<jats:styled-content style=\"fixed-case\">AUC<\/jats:styled-content>) and jackknife free\u2010response receiver operating characteristics (<jats:styled-content style=\"fixed-case\">JAFROC<\/jats:styled-content>) figure of merit (<jats:styled-content style=\"fixed-case\">FOM<\/jats:styled-content>).<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>There was no significant improvement in overall reader performance in detecting abnormalities in zooming condition compared with no zooming in terms of case sensitivity (96% and 87%, <jats:italic>P<\/jats:italic>\u2009=\u20090.285) or lesion sensitivity (88% and 81%, <jats:italic>P<\/jats:italic>\u2009=\u20090.224). However, differences in <jats:styled-content style=\"fixed-case\">ROC AUC<\/jats:styled-content> and <jats:styled-content style=\"fixed-case\">JAFROC FOM<\/jats:styled-content> (<jats:italic>P<\/jats:italic>\u2009\u2264\u20090.05) were found in two readers when they performed the test set with zooming function.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The results suggested that the use of the zooming function did improve the performance of some readers in detecting abnormal cases.<\/jats:p><\/jats:sec>","DOI":"10.1111\/1754-9485.12298","type":"journal-article","created":{"date-parts":[[2015,4,2]],"date-time":"2015-04-02T20:04:01Z","timestamp":1428005041000},"page":"292-299","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of the effect of zoom function on lesion detection by soft\u2010copy reading of screening mammograms"],"prefix":"10.1111","volume":"59","author":[{"given":"Phuong Dung","family":"Trieu","sequence":"first","affiliation":[{"name":"Medical Image Optimization and Perception (MIOPeG) Faculty of Health Sciences University of Sydney  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick","family":"Brennan","sequence":"additional","affiliation":[{"name":"Medical Image Optimization and Perception (MIOPeG) Faculty of Health Sciences University of Sydney  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bruno","family":"Giuffre","sequence":"additional","affiliation":[{"name":"Radiology Department Royal North Shore Hospital  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claudia","family":"Mello\u2010Thoms","sequence":"additional","affiliation":[{"name":"Medical Image Optimization and Perception (MIOPeG) Faculty of Health Sciences University of Sydney  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kriscia","family":"Tapia","sequence":"additional","affiliation":[{"name":"Medical Image Optimization and Perception (MIOPeG) Faculty of Health Sciences University of Sydney  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicole","family":"Santangelo","sequence":"additional","affiliation":[{"name":"BreastScreen NSW Sydney South West Area Health Service  Sydney New South Wales Australia"},{"name":"Radiology Department Concord Hospital  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Haewon","family":"Kim","sequence":"additional","affiliation":[{"name":"BreastScreen NSW Sydney South West Area Health Service  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katherine","family":"Cameron","sequence":"additional","affiliation":[{"name":"Imaging Partners Online  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Catherine","family":"Hayter","sequence":"additional","affiliation":[{"name":"Radiology Department Royal North Shore Hospital  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Glenys","family":"Da Costa","sequence":"additional","affiliation":[{"name":"Radiology Department Royal North Shore Hospital  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jarmila","family":"Sterba","sequence":"additional","affiliation":[{"name":"South Eastern Sydney Illawarra BreastScreen Service  Sydney New South Wales Australia"},{"name":"BreastScreen NSW Northern Sydney and Central Coast Local  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Warwick","family":"Lee","sequence":"additional","affiliation":[{"name":"Medical Image Optimization and Perception (MIOPeG) Faculty of Health Sciences University of Sydney  Sydney New South Wales Australia"},{"name":"BreastScreen NSW Cancer Institute NSW  Sydney New South Wales Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2015,4]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.5694\/j.1326-5377.2007.tb01420.x"},{"key":"e_1_2_7_3_1","first-page":"7","volume-title":"Practice Guidelines & Technical Standards","author":"American College of Radiology","year":"2014"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2009.07.010"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00117-002-0733-2"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-008-1135-2"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10278-009-9177-9"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.05.1397"},{"key":"e_1_2_7_9_1","first-page":"144","volume-title":"Proceedings of the SPIE, Medical Imaging: Image Perception, Observer Performance and Technology Assessment","author":"Chakraborty DP","year":"2004"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacr.2006.02.021"},{"key":"e_1_2_7_11_1","first-page":"173","article-title":"Detecting clustered microcalcifications in the female breast: secondary digitized images versus mammograms","volume":"75","author":"De Maeseneer M","year":"1992","journal-title":"J Belge Radiol"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2293021171"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10278-005-7666-z"}],"container-title":["Journal of Medical Imaging and Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2F1754-9485.12298","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/1754-9485.12298","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T07:46:23Z","timestamp":1696232783000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/1754-9485.12298"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,4]]},"references-count":12,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2015,6]]}},"alternative-id":["10.1111\/1754-9485.12298"],"URL":"https:\/\/doi.org\/10.1111\/1754-9485.12298","archive":["Portico"],"relation":{},"ISSN":["1754-9477","1754-9485"],"issn-type":[{"type":"print","value":"1754-9477"},{"type":"electronic","value":"1754-9485"}],"subject":[],"published":{"date-parts":[[2015,4]]},"assertion":[{"value":"2014-10-23","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2015-01-26","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2015-04-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}