{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T14:44:56Z","timestamp":1773153896500,"version":"3.50.1"},"reference-count":41,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2007,3,22]],"date-time":"2007-03-22T00:00:00Z","timestamp":1174521600000},"content-version":"vor","delay-in-days":8299,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[1984,7]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>\n                    The cerebral function analysing monitor is a development of the cerebral function monitor. It produces a more detailed analysis of the electroencephalogram (EEG) amplitude and analyses the frequency of the waveforms into standard\n                    <jats:italic>beta, alpha, theta<\/jats:italic>\n                    and\n                    <jats:italic>delta<\/jats:italic>\n                    bands. It can analyse the EEG from two input channels, produce traces of the standard EEG, and compute visual, auditory, somato sensory and brain stem evoked potentials.\n                  <\/jats:p>","DOI":"10.1111\/j.1365-2044.1984.tb06477.x","type":"journal-article","created":{"date-parts":[[2007,3,22]],"date-time":"2007-03-22T08:54:53Z","timestamp":1174553693000},"page":"678-690","source":"Crossref","is-referenced-by-count":53,"title":["The cerebral function analysing monitor Initial clinical experience, application and further development"],"prefix":"10.1111","volume":"39","author":[{"given":"D. E.","family":"MAYNARD","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. L.","family":"JENKINSON","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2007,3,22]]},"reference":[{"key":"e_1_2_1_1_2","first-page":"479","article-title":"The cerebral function analysing monitor (CFAM)","volume":"43","author":"Maynard DE","year":"1977","journal-title":"Electroencephalography and Clinical Neurophysiology"},{"key":"e_1_2_1_2_2","first-page":"253","article-title":"Development of the CFM: The cerebral function analysing monitor","volume":"20","author":"Maynard DE","year":"1979","journal-title":"Annales de L'Anesthesiologie Francaise"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.4.5682.545-a"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/53.6.639"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1973.tb00545.x"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1136\/thx.28.4.464"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1136\/thx.30.3.258"},{"key":"e_1_2_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1973.tb00544.x"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.44.10.924"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1978.tb08343.x"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/54.6.609"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/50.10.993"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1528-1157.1973.tb03975.x"},{"key":"e_1_2_1_14_2","first-page":"325","volume-title":"Epileptology. Proceedings of the seventh international symposium on epilepsy","author":"Prior PF","year":"1976"},{"key":"e_1_2_1_15_2","volume-title":"Monitoring cerebral function: long term recordings of cerebral electrical activity","author":"Prior PF","year":"1979"},{"key":"e_1_2_1_16_2","first-page":"234","article-title":"A note of the nature of the non\u2010rhythmic components of the electroencephalogram","volume":"11","author":"Maynard DE","year":"1969","journal-title":"Activitas Nervosa Superior"},{"key":"e_1_2_1_17_2","first-page":"55","volume-title":"Automation of clinical electroencephalography","author":"Bickford RG","year":"1973"},{"key":"e_1_2_1_18_2","volume-title":"EEG processing in cardiac surgery","author":"Pronk RAF"},{"key":"e_1_2_1_19_2","first-page":"101","article-title":"The values and limitations of EEG monitoring in intensive care units","volume":"32","author":"Bickford RG","year":"1972","journal-title":"Electroencephalography and Clinical Neurophysiology"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/0013-4694(79)90015-4"},{"key":"e_1_2_1_21_2","article-title":"Comparison of plasma thiopentone concentrations and the cerebral function analysing monitor during repeated bolus injections of thiopentone","author":"Frank M","journal-title":"British Journal of Anasthesia"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/55.12.1265"},{"key":"e_1_2_1_23_2","article-title":"The effect of nitrous oxide as assessed by the cerebral function analysing monitor (CFAM)","author":"Williams DJM","journal-title":"British Journal of Anasthesia"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-198301000-00011"},{"key":"e_1_2_1_25_2","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1097\/00000542-197306000-00011","article-title":"Neurophysiologic effects of general anasthesia: I. The electroencephalogram and sensory evoked responses in man","volume":"38","author":"Clarke DL","year":"1973","journal-title":"Anesthesiology"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-198210000-00015"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.282.6263.520"},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(78)90712-2"},{"key":"e_1_2_1_29_2","volume-title":"Controlled hypotension in neuroanasthesia","author":"Prior PF","year":"1983"},{"key":"e_1_2_1_30_2","first-page":"347","volume-title":"Clinical neurophysiology","author":"Prior PF","year":"1981"},{"key":"e_1_2_1_31_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.4.5730.265"},{"key":"e_1_2_1_32_2","volume-title":"The EEG in acute cerebral anoxia","author":"Prior PF","year":"1973"},{"key":"e_1_2_1_33_2","first-page":"297","volume-title":"Fetal and neonatal physiological measurements","author":"Viniker DA","year":"1980"},{"key":"e_1_2_1_34_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.1979.tb11241.x"},{"key":"e_1_2_1_35_2","first-page":"315","volume-title":"Fetal and neonatal physiological measurements","author":"Maynard DE","year":"1980"},{"key":"e_1_2_1_36_2","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1177\/155005948201300106","article-title":"Prediction of outcome in neonates using the EEG","volume":"13","author":"Obrecht R","year":"1982","journal-title":"Clinical electroencephalography"},{"key":"e_1_2_1_37_2","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/0002-9378(76)90373-2","article-title":"Computer interpreted fetal electroencephalogram. 1. Relative frequency of patterns","volume":"125","author":"Chik L","year":"1976","journal-title":"American Journal of Obstetrics and Gynecology"},{"key":"e_1_2_1_38_2","first-page":"744","article-title":"A predictive instrument to assist with interpretation of EEGs of patients resuscitated after cardiac arrest","volume":"34","author":"Maynard DE","year":"1973","journal-title":"Electroencephalography and Clinical Neurophysiology"},{"key":"e_1_2_1_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/0013-4694(70)90271-3"},{"key":"e_1_2_1_40_2","first-page":"269","volume-title":"Automation of clinical electroencephalography","author":"Viglione SS","year":"1973"},{"key":"e_1_2_1_41_2","first-page":"243","volume-title":"Automation of clinical electroencephalography","author":"Larsen LE","year":"1973"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1365-2044.1984.tb06477.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1365-2044.1984.tb06477.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T17:41:34Z","timestamp":1761673294000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1111\/j.1365-2044.1984.tb06477.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1984,7]]},"references-count":41,"journal-issue":{"issue":"7","published-print":{"date-parts":[[1984,7]]}},"alternative-id":["10.1111\/j.1365-2044.1984.tb06477.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1365-2044.1984.tb06477.x","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"value":"0003-2409","type":"print"},{"value":"1365-2044","type":"electronic"}],"subject":[],"published":{"date-parts":[[1984,7]]}}}