{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T14:11:13Z","timestamp":1773324673016,"version":"3.50.1"},"reference-count":45,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2007,12,6]],"date-time":"2007-12-06T00:00:00Z","timestamp":1196899200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Oral Implants Res"],"published-print":{"date-parts":[[2008,2]]},"abstract":"<jats:title>Abstract:<\/jats:title><jats:p><jats:bold>Objectives: <\/jats:bold> Primary implant stability is related to local bone density. After insertion of an implant, implant stability is subject to changes due to bone remodeling. In patients who have undergone radiotherapy in the head and neck region, implant stability is impaired because irradiation reduces bone vitality. The current study was designed to monitor and test implant stability immediately after implant placement and during osseointegration in irradiated and non\u2010irradiated minipig alveolar bone.<\/jats:p><jats:p><jats:bold>Materials and methods: <\/jats:bold> All maxillary and mandibular premolars and molars of six adult G\u00f6ttingen minipigs were extracted. The maxilla and mandible of three minipigs received three irradiation exposures at a total dose of 24\u2003Gy. After irradiation, five initial implant holes were drilled in the residual alveolar ridge of each edentulous site. In order to assess bone vascularity, laser Doppler flowmetry recordings were carried out in the initial holes. A total of 120 implants were placed in the six minipigs. Subsequently, and at 8, 16, and 24 weeks after implant placement, implant stability was recorded by resonance frequency analysis (RFA). RFA values were expressed as an implant stability quotient (ISQ).<\/jats:p><jats:p><jats:bold>Results: <\/jats:bold> ISQ values recorded immediately after implant placement showed no differences between irradiated and non\u2010irradiated minipigs. Repeated measurements at the four recording moments showed a decrease of ISQ values in all minipigs, being more pronounced in irradiated bone, when compared with non\u2010irradiated bone. The results at the third and fourth recording moments showed a stabilization or even a slight increase of ISQ values.<\/jats:p><jats:p><jats:bold>Conclusions: <\/jats:bold> The results document the negative effect of irradiation on bone vascularity and hence on implant stability.<\/jats:p>","DOI":"10.1111\/j.1600-0501.2007.01457.x","type":"journal-article","created":{"date-parts":[[2009,5,1]],"date-time":"2009-05-01T12:18:54Z","timestamp":1241180334000},"page":"201-206","source":"Crossref","is-referenced-by-count":28,"title":["Implant stability during osseointegration in irradiated and non\u2010irradiated minipig alveolar bone: an experimental study"],"prefix":"10.1111","volume":"19","author":[{"given":"Henk W. D.","family":"Verdonck","sequence":"first","affiliation":[]},{"given":"Gert J.","family":"Meijer","sequence":"additional","affiliation":[]},{"given":"Thorsten","family":"Laurin","sequence":"additional","affiliation":[]},{"given":"Fred H.","family":"Nieman","sequence":"additional","affiliation":[]},{"given":"Christian","family":"Stoll","sequence":"additional","affiliation":[]},{"given":"Dieter","family":"Riediger","sequence":"additional","affiliation":[]},{"given":"Paul J. W.","family":"Stoelinga","sequence":"additional","affiliation":[]},{"given":"Cees de","family":"Baat","sequence":"additional","affiliation":[]}],"member":"311","published-online":{"date-parts":[[2007,12,6]]},"reference":[{"key":"e_1_2_6_2_1","first-page":"327","article-title":"The impact of oral implants \u2013 past and future 1996\u20132042","volume":"71","author":"Albrektsson T.","year":"2005","journal-title":"Journal of the Canadian Dental Association"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(97)70232-4"},{"key":"e_1_2_6_4_1","first-page":"463","article-title":"Immediate loading of implants with mandibular overdentures","volume":"18","author":"Attard N.J.","year":"2005","journal-title":"International Journal of Prosthodontics"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2002.tb00162.x"},{"key":"e_1_2_6_6_1","first-page":"584","article-title":"A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants","volume":"20","author":"Balshi S.F.","year":"2005","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2005.76.3.391"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2004.01042.x"},{"key":"e_1_2_6_9_1","first-page":"1","article-title":"Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10\u2010year period","volume":"16","author":"Br\u00e5nemark P.I.","year":"1977","journal-title":"Scandinavian Journal of Plastic and Reconstructive Surgery"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijom.2006.03.016"},{"key":"e_1_2_6_11_1","first-page":"511","article-title":"Implants placed in an irradiated dog mandible","volume":"15","author":"Brogniez V.","year":"2000","journal-title":"International Journal of Oral and Maxillofacial Implants"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2002.130302.x"},{"key":"e_1_2_6_13_1","first-page":"211","article-title":"A survey of the use of mandibular implant overdentures in 10 countries","volume":"17","author":"Carlsson G.E.","year":"2004","journal-title":"International Journal of Prosthodontics"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1053\/joms.2001.22680"},{"key":"e_1_2_6_15_1","first-page":"855","article-title":"Immediate restoration of single\u2010tooth implants in mandibular molar sites","volume":"19","author":"Cornelini R.","year":"2004","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_16_1","first-page":"578","article-title":"A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single\u2010tooth implants under immediate loading","volume":"19","author":"Da Cunha H.A.","year":"2004","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2005.01156.x"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2005.76.7.1066"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2004.tb00024.x"},{"key":"e_1_2_6_20_1","first-page":"486","article-title":"The use and abuse of the Periotest for 2\u2010piece implant\/abutment systems","volume":"16","author":"Faulkner M.G.","year":"2001","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_21_1","first-page":"524","article-title":"Immediate loading with fixed screw\u2010retained provisional restorations in edentulous jaws","volume":"19","author":"Gallucci G.O.","year":"2004","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_22_1","first-page":"653","article-title":"A detailed analysis of titanium implants lost in irradiated tissues","volume":"9","author":"Granstr\u00f6m G.","year":"1994","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0278-2391(99)90059-9"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2005.01.008"},{"key":"e_1_2_6_25_1","first-page":"140","article-title":"Micromorphological findings in jaw bone after radiotherapy","volume":"3","author":"Grotz K.A.","year":"1999","journal-title":"Mund-, Kiefer- und Gesichtschirurgie"},{"key":"e_1_2_6_26_1","first-page":"800","article-title":"Mandibular endosseous implants and autogenous bone grafting in irradiated tissue","volume":"12","author":"Keller E.E.","year":"1997","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2005.01173.x"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2005.01174.x"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2005.01227.x"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1996.070405.x"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1615\/CritRevBiomedEng.v26.i4.20"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1996.070308.x"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1997.080310.x"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2004.01059.x"},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3913(98)70070-8"},{"key":"e_1_2_6_36_1","first-page":"39","article-title":"Immediate versus delayed loading of dental implants in the maxillae of minipigs","volume":"20","author":"Nkenke E.","year":"2005","journal-title":"International Journal of Oral & Maxillofacial Implants"},{"key":"e_1_2_6_37_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2003.tb00019.x"},{"key":"e_1_2_6_38_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2005.tb00076.x"},{"key":"e_1_2_6_39_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2005.tb00057.x"},{"key":"e_1_2_6_40_1","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1002\/(SICI)1097-4636(199822)43:2<192::AID-JBM14>3.0.CO;2-K","article-title":"Timing of loading and effect of micromotion on bone\u2013dental implant interface","volume":"43","author":"Szmukler\u2010Moncler S.","year":"1998","journal-title":"Journal of Biomedical Materials Research"},{"key":"e_1_2_6_41_1","doi-asserted-by":"publisher","DOI":"10.1177\/08959374990130010201"},{"key":"e_1_2_6_42_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1708-8208.2005.tb00084.x"},{"key":"e_1_2_6_43_1","article-title":"Assessment of vascularity in irradiated and non\u2010irradiated maxillary and mandibular alveolar minipig bone using laser Doppler flowmetry","author":"Verdonck H.W.D.","year":"2007","journal-title":"International Journal of Oral and Maxillofacial Implants"},{"key":"e_1_2_6_44_1","doi-asserted-by":"publisher","DOI":"10.1177\/154405910208101212"},{"key":"e_1_2_6_45_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0501.2005.01160.x"},{"key":"e_1_2_6_46_1","first-page":"747","article-title":"Stability measurements of 1\u2010stage implants in the maxilla by means of resonance frequency analysis","volume":"20","author":"Zix J.","year":"2005","journal-title":"International Journal of Oral & Maxillofacial Implants"}],"container-title":["Clinical Oral Implants Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fj.1600-0501.2007.01457.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/j.1600-0501.2007.01457.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T20:34:30Z","timestamp":1697402070000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/j.1600-0501.2007.01457.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,12,6]]},"references-count":45,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2008,2]]}},"alternative-id":["10.1111\/j.1600-0501.2007.01457.x"],"URL":"https:\/\/doi.org\/10.1111\/j.1600-0501.2007.01457.x","archive":["Portico"],"relation":{},"ISSN":["0905-7161","1600-0501"],"issn-type":[{"value":"0905-7161","type":"print"},{"value":"1600-0501","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,12,6]]}}}