{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T10:13:53Z","timestamp":1783505633865,"version":"3.55.0"},"reference-count":27,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2015,6,5]],"date-time":"2015-06-05T00:00:00Z","timestamp":1433462400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[2015,11]]},"abstract":"<jats:sec><jats:title>Background<\/jats:title><jats:p>Extracorporeal membrane oxygenation (<jats:styled-content style=\"fixed-case\">ECMO<\/jats:styled-content>) is increasingly used in patients with severe respiratory failure. Indirect calorimetry (<jats:styled-content style=\"fixed-case\">IC<\/jats:styled-content>) is a safe and non\u2010invasive method for measuring resting energy expenditure (<jats:styled-content style=\"fixed-case\">REE<\/jats:styled-content>). No data exist on the use of <jats:styled-content style=\"fixed-case\">IC<\/jats:styled-content> in <jats:styled-content style=\"fixed-case\">ECMO<\/jats:styled-content>\u2010treated patients as oxygen uptake and carbon dioxide elimination are divided between mechanical ventilation and the artificial lung. We report our preliminary clinical experience with a theoretical model that derives <jats:styled-content style=\"fixed-case\">REE<\/jats:styled-content> from <jats:styled-content style=\"fixed-case\">IC<\/jats:styled-content> measurements obtained separately on the ventilator and on the artificial lung.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A patient undergoing veno\u2010venous <jats:styled-content style=\"fixed-case\">ECMO<\/jats:styled-content> for acute respiratory failure due to bilateral pneumonia was studied. The calorimeter was first connected to the ventilator and oxygen consumption (<jats:styled-content style=\"fixed-case\">VO<\/jats:styled-content><jats:sub>2<\/jats:sub>) and carbon dioxide transport (<jats:styled-content style=\"fixed-case\">VCO<\/jats:styled-content><jats:sub>2<\/jats:sub>) were measured until steady state was reached. Subsequently, the <jats:styled-content style=\"fixed-case\">IC<\/jats:styled-content> was connected to the membrane oxygenator and similar gas analysis was performed. <jats:styled-content style=\"fixed-case\">VO<\/jats:styled-content><jats:sub>2<\/jats:sub> and <jats:styled-content style=\"fixed-case\">VCO<\/jats:styled-content><jats:sub>2<\/jats:sub> values at the native and artificial lung were summed and incorporated in the Weir equation to obtain a <jats:styled-content style=\"fixed-case\">REE<\/jats:styled-content><jats:sub>composite<\/jats:sub>.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>At the ventilator level, <jats:styled-content style=\"fixed-case\">VO<\/jats:styled-content><jats:sub>2<\/jats:sub> and <jats:styled-content style=\"fixed-case\">VCO<\/jats:styled-content><jats:sub>2<\/jats:sub> were 29.5\u00a0ml\/min and 16\u00a0ml\/min. <jats:styled-content style=\"fixed-case\">VO<\/jats:styled-content><jats:sub>2<\/jats:sub> and <jats:styled-content style=\"fixed-case\">VCO<\/jats:styled-content><jats:sub>2<\/jats:sub> at the artificial lung level were 213\u00a0ml\/min and 187\u00a0ml\/min. Based on these values, a <jats:styled-content style=\"fixed-case\">REE<\/jats:styled-content><jats:sub>composite<\/jats:sub> of 1703\u00a0kcal\/day was obtained. The Faisy\u2013Fagon and Harris\u2013Benedict equations calculated a <jats:styled-content style=\"fixed-case\">REE<\/jats:styled-content> of 1373 and 1563\u00a0kcal\/day.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>We present <jats:styled-content style=\"fixed-case\">IC<\/jats:styled-content>\u2010acquired gas analysis in <jats:styled-content style=\"fixed-case\">ECMO<\/jats:styled-content> patients. We propose to insert individually obtained <jats:styled-content style=\"fixed-case\">IC<\/jats:styled-content> measurements at the native and the artificial lung in the Weir equation for retrieving a measured <jats:styled-content style=\"fixed-case\">REE<\/jats:styled-content><jats:sub>composite<\/jats:sub>.<\/jats:p><\/jats:sec>","DOI":"10.1111\/aas.12564","type":"journal-article","created":{"date-parts":[[2015,6,5]],"date-time":"2015-06-05T13:16:42Z","timestamp":1433510202000},"page":"1296-1302","source":"Crossref","is-referenced-by-count":47,"title":["Measuring resting energy expenditure during extracorporeal membrane oxygenation: preliminary clinical experience with a proposed theoretical model"],"prefix":"10.1111","volume":"59","author":[{"given":"E.","family":"De Waele","sequence":"first","affiliation":[{"name":"Intensive Care Department Universitair Ziekenhuis Brussel (UZ Brussel) Vrije Universiteit Brussel (VUB) Brussels Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"van Zwam","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery Universitair Ziekenhuis Brussel (UZ Brussel) Brussels Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Mattens","sequence":"additional","affiliation":[{"name":"Intensive Care Department Universitair Ziekenhuis Brussel (UZ Brussel) Vrije Universiteit Brussel (VUB) Brussels Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Staessens","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery Universitair Ziekenhuis Brussel (UZ Brussel) Brussels Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Diltoer","sequence":"additional","affiliation":[{"name":"Intensive Care Department Universitair Ziekenhuis Brussel (UZ Brussel) Vrije Universiteit Brussel (VUB) Brussels Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. M.","family":"Honor\u00e9","sequence":"additional","affiliation":[{"name":"Intensive Care Department Universitair Ziekenhuis Brussel (UZ Brussel) Vrije Universiteit Brussel (VUB) Brussels Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Czapla","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery Universitair Ziekenhuis Brussel (UZ Brussel) Brussels Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Nijs","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery Universitair Ziekenhuis Brussel (UZ Brussel) Brussels Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"La Meir","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery Universitair Ziekenhuis Brussel (UZ Brussel) Brussels Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Huyghens","sequence":"additional","affiliation":[{"name":"Intensive Care Department Universitair Ziekenhuis Brussel (UZ Brussel) Vrije Universiteit Brussel (VUB) Brussels Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.","family":"Spapen","sequence":"additional","affiliation":[{"name":"Intensive Care Department Universitair Ziekenhuis Brussel (UZ Brussel) Vrije Universiteit Brussel (VUB) Brussels Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2015,6,5]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clnu.2009.04.024"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.1949.sp004363"},{"key":"e_1_2_8_4_1","doi-asserted-by":"crossref","unstructured":"FrankenfieldDC.On heat respiration and calorimetry. Nutrition2010;26:939\u201350.","DOI":"10.1016\/j.nut.2010.01.002"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.201311-2023OC"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1053\/jpsu.2001.20007"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3468(88)80194-5"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/0884533614521835"},{"key":"e_1_2_8_9_1","first-page":"1170","article-title":"Metabolic measurement using indirect calorimetry during mechanical ventilation. American Association for Respiratory Care","volume":"39","author":"AARC Clinical Practice Guideline","year":"1994","journal-title":"Respir Care"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.3945\/ajcn.112.035014"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1177\/0148607197021003168"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1093\/ajcn\/78.2.241"},{"key":"e_1_2_8_13_1","volume-title":"Biometric studies of basal metabolism in man","author":"Harris JA","year":"1919"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1093\/ajcn\/40.1.168"},{"key":"e_1_2_8_15_1","first-page":"272","article-title":"Measured versus calculated resting energy expenditure in critically ill adult patients. Do mathematics match the gold standard?","volume":"81","author":"De Waele E","year":"2015","journal-title":"Minerva Anestesiol"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-013-3053-2"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1159\/000350610"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3468(99)90572-9"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1159\/000341292"},{"key":"e_1_2_8_20_1","unstructured":"ELSO Guidelines for Cardiopulmonary Extracorporeal Life Support Extracorporeal Life Support Organization Version 1.3 November 2013.Ann Arbor MI. Available at:www.elsonet.org(accessed 15 January 2015)."},{"key":"e_1_2_8_21_1","first-page":"230","article-title":"Nutritional support in adult patients receiving extracorporeal membrane oxygenation","volume":"12","author":"Lukas G","year":"2010","journal-title":"Crit Care Resusc"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/cc7993"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(12)61351-8"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3468(85)80045-2"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-3468(94)90270-4"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1203\/00006450-200103000-00014"},{"key":"e_1_2_8_27_1","unstructured":"Guidance for Cardiopulmonary Bypass Oxygenators 510(k) Submissions; Final Guidance for Industry and FDA Staff.U.S. Department of Health and Human Services. Food and Drug Administration. Center for Devices and Radiological Health. January 17 2000."},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1177\/0267659112469642"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faas.12564","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aas.12564","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T17:25:39Z","timestamp":1696353939000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aas.12564"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,6,5]]},"references-count":27,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2015,11]]}},"alternative-id":["10.1111\/aas.12564"],"URL":"https:\/\/doi.org\/10.1111\/aas.12564","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,6,5]]}}}