{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T21:48:48Z","timestamp":1791841728434,"version":"4.3.4"},"reference-count":111,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2015,9,1]],"date-time":"2015-09-01T00:00:00Z","timestamp":1441065600000},"content-version":"tdm","delay-in-days":639,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Aust Dent J"],"published-print":{"date-parts":[[2013,12]]},"DOI":"10.1111\/adj.12111","type":"journal-article","created":{"date-parts":[[2013,12,4]],"date-time":"2013-12-04T14:33:00Z","timestamp":1386167580000},"page":"408-419","source":"Crossref","is-referenced-by-count":58,"title":["Clinical guidelines for oral appliance therapy in the treatment of snoring and obstructive sleep apnoea"],"prefix":"10.1111","volume":"58","author":[{"given":"J","family":"Ngiam","sequence":"first","affiliation":[{"name":"Department of Respiratory and Sleep Medicine; Royal North Shore Hospital; Sydney New South Wales"},{"name":"Faculty of Medicine; The University of Sydney; New South Wales"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R","family":"Balasubramaniam","sequence":"additional","affiliation":[{"name":"School of Dentistry; The University of Western Australia; Nedlands Western Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MA","family":"Darendeliler","sequence":"additional","affiliation":[{"name":"Department of Orthodontics; The University of Sydney; Sydney Dental Hospital; Sydney and South Western Sydney Local Health Districts; New South Wales"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"AT","family":"Cheng","sequence":"additional","affiliation":[{"name":"Discipline of Paediatrics and Child Health; The University of Sydney; New South Wales"},{"name":"Department of Paediatric Otolaryngology; The Children's Hospital at Westmead; New South Wales"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K","family":"Waters","sequence":"additional","affiliation":[{"name":"SIDS and Sleep Apnoea Research Group; The Children's Hospital at Westmead; New South Wales"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"CE","family":"Sullivan","sequence":"additional","affiliation":[{"name":"Faculty of Medicine; The University of Sydney; New South Wales"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2013,12,3]]},"reference":[{"key":"10.1111\/adj.12111-BIB0001|adj12111-cit-0001","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1016\/S0272-5231(21)00401-9","article-title":"Obstructive sleep apnea","volume":"6","author":"Sullivan","year":"1985","journal-title":"Clin Chest Med"},{"key":"10.1111\/adj.12111-BIB0002|adj12111-cit-0002","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1164\/rccm.2109080","article-title":"Epidemiology of obstructive sleep apnea: a population health perspective","volume":"165","author":"Young","year":"2002","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0003|adj12111-cit-0003","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1136\/thx.46.2.85","article-title":"Predictors and prevalence of obstructive sleep apnoea and snoring in 1001 middle aged men","volume":"46","author":"Stradling","year":"1991","journal-title":"Thorax"},{"key":"10.1111\/adj.12111-BIB0004|adj12111-cit-0004","doi-asserted-by":"crossref","first-page":"1459","DOI":"10.1164\/ajrccm.151.5.7735600","article-title":"Snoring and sleep apnea","volume":"151","author":"Bearpark","year":"1995","journal-title":"A population study in Australian men. Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0005|adj12111-cit-0005","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1093\/sleep\/3.3-4.235","article-title":"Pathophysiological mechanisms in obstructive sleep apnea","volume":"3","author":"Sullivan","year":"1980","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0006|adj12111-cit-0006","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1513\/pats.200707-114MG","article-title":"Pathophysiology of adult obstructive sleep apnea","volume":"5","author":"Eckert","year":"2008","journal-title":"Proc Am Thorac Soc"},{"key":"10.1111\/adj.12111-BIB0007|adj12111-cit-0007","first-page":"1079","article-title":"Sleep apnea as an independent risk factor for all-cause mortality: the Busselton Health Study","volume":"31","author":"Marshall","year":"2008","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0008|adj12111-cit-0008","doi-asserted-by":"crossref","first-page":"15","DOI":"10.5664\/jcsm.27387","article-title":"Is sleep apnea an independent risk factor for prevalent and incident diabetes in the Busselton Health Study?","volume":"5","author":"Marshall","year":"2009","journal-title":"J Clin Sleep Med"},{"key":"10.1111\/adj.12111-BIB0009|adj12111-cit-0009","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1016\/j.pcad.2009.01.002","article-title":"Obstructive sleep apnea and cardiovascular disease: a perspective and future directions","volume":"51","author":"Pack","year":"2009","journal-title":"Prog Cardiovasc Dis"},{"key":"10.1111\/adj.12111-BIB0010|adj12111-cit-0010","first-page":"1207","article-title":"Heavy snoring as a cause of carotid artery atherosclerosis","volume":"31","author":"Lee","year":"2008","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0011|adj12111-cit-0011","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1161\/HYPERTENSIONAHA.108.119420","article-title":"Additive effects of obstructive sleep apnea and hypertension on early markers of carotid atherosclerosis","volume":"53","author":"Drager","year":"2009","journal-title":"Hypertension"},{"key":"10.1111\/adj.12111-BIB0012|adj12111-cit-0012","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1183\/09031936.00077409","article-title":"Nasopharyngoscopic evaluation of oral appliance therapy for obstructive sleep apnoea","volume":"35","author":"Chan","year":"2009","journal-title":"Eur Respir J"},{"key":"10.1111\/adj.12111-BIB0013|adj12111-cit-0013","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1136\/thx.2009.131094","article-title":"The effect of mandibular advancement on upper airway structure in obstructive sleep apnoea","volume":"65","author":"Chan","year":"2010","journal-title":"Thorax"},{"key":"10.1111\/adj.12111-BIB0014|adj12111-cit-0014","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1007\/BF03045024","article-title":"Mandibular advancement modulates respiratory-related genioglossus electromyographic activity","volume":"4","author":"Tsuiki","year":"2000","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0015|adj12111-cit-0015","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1111\/j.1475-097X.2007.00714.x","article-title":"The effect of mandibular advancement appliances on awake upper airway and masticatory muscle activity in patients with obstructive sleep apnoea","volume":"27","author":"Johal","year":"2007","journal-title":"Clin Physiol Funct Imaging"},{"key":"10.1111\/adj.12111-BIB0016|adj12111-cit-0016","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1164\/rccm.200311-1571OC","article-title":"Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea","volume":"170","author":"Barnes","year":"2004","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0017|adj12111-cit-0017","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1164\/rccm.200203-208OC","article-title":"Oral appliance therapy improves symptoms in obstructive sleep apnea: a randomized, controlled trial","volume":"166","author":"Gotsopoulos","year":"2002","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0018|adj12111-cit-0018","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1177\/154411130401500303","article-title":"Efficacy and co-morbidity of oral appliances in the treatment of obstructive sleep apnea-hypopnea: a systematic review","volume":"15","author":"Hoekema","year":"2004","journal-title":"Crit Rev Oral Biol Med"},{"key":"10.1111\/adj.12111-BIB0019|adj12111-cit-0019","unstructured":"Dental Board of Australia Policies, Codes, and Guidelines, 2012 http:\/\/www.dentalboard.gov.au"},{"key":"10.1111\/adj.12111-BIB0020|adj12111-cit-0020","unstructured":"Australasian Sleep Association Dental appliance therapy for treatment of sleep-disordered breathing, July 2010 http:\/\/www.sleep.org.au"},{"key":"10.1111\/adj.12111-BIB0021|adj12111-cit-0021","unstructured":"Australian Dental Association Inc Policy Statement 6.7. Use of dental appliances to treat sleep-disordered breathing. April 2012 http:\/\/www.ada.org.au"},{"key":"10.1111\/adj.12111-BIB0022|adj12111-cit-0022","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1164\/ajrccm.165.1.2011031","article-title":"Randomized controlled study of an oral jaw positioning appliance for the treatment of obstructive sleep apnea in children with malocclusion","volume":"165","author":"Villa","year":"2002","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0023|adj12111-cit-0023","first-page":"241","article-title":"A modified monobloc for treatment of young children with obstructive sleep apnea","volume":"38","author":"Cozza","year":"2004","journal-title":"J Clin Orthod"},{"key":"10.1111\/adj.12111-BIB0024|adj12111-cit-0024","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1001\/archoto.2008.521","article-title":"Rapid maxillary expansion for the treatment of nasal obstruction in children younger than 12\u00a0years","volume":"135","author":"Monini","year":"2009","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"10.1111\/adj.12111-BIB0025|adj12111-cit-0025","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.sleep.2006.06.009","article-title":"Rapid maxillary expansion in children with obstructive sleep apnea syndrome: 12-month follow-up","volume":"8","author":"Villa","year":"2007","journal-title":"Sleep Med"},{"key":"10.1111\/adj.12111-BIB0026|adj12111-cit-0026","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1007\/s11325-011-0505-1","article-title":"Efficacy of rapid maxillary expansion in children with obstructive sleep apnea syndrome: 36\u00a0months of follow-up","volume":"15","author":"Villa","year":"2011","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0027|adj12111-cit-0027","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1513\/pats.200707-114MG","article-title":"Pathophysiology of adult obstructive sleep apnea","volume":"5","author":"Eckert","year":"2008","journal-title":"Proc Am Thorac Soc"},{"key":"10.1111\/adj.12111-BIB0028|adj12111-cit-0028","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1055\/s-2000-19520","article-title":"Site specific versus diffuse treatment\/presenting severity of obstructive sleep apnea","volume":"4","author":"Moore","year":"2000","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0029|adj12111-cit-0029","first-page":"101","volume-title":"Snoring and obstructive sleep apnea","author":"Fujita","year":"1987"},{"key":"10.1111\/adj.12111-BIB0030|adj12111-cit-0030","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1177\/019459988609400510","article-title":"Inferior sagittal osteotomy of the mandible with hyoid myotomy-suspension: a new procedure for obstructive sleep apnea","volume":"94","author":"Riley","year":"1986","journal-title":"Otolaryngol Head Neck Surg"},{"key":"10.1111\/adj.12111-BIB0031|adj12111-cit-0031","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1016\/j.otohns.2005.10.021","article-title":"Lingual tonsillectomy using bipolar radiofrequency plasma excision","volume":"134","author":"Robinson","year":"2006","journal-title":"Otolaryngol Head Neck Surg"},{"key":"10.1111\/adj.12111-BIB0032|adj12111-cit-0032","doi-asserted-by":"crossref","first-page":"1273","DOI":"10.1097\/00005537-199908000-00017","article-title":"Tongue base reduction with hyoepiglottoplasty: a treatment for severe obstructive sleep apnea","volume":"109","author":"Chabolle","year":"1999","journal-title":"Laryngoscope"},{"key":"10.1111\/adj.12111-BIB0033|adj12111-cit-0033","first-page":"153","volume-title":"Surgery for sleep disordered breathing","author":"Maurer","year":"2010"},{"key":"10.1111\/adj.12111-BIB0034|adj12111-cit-0034","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1016\/0278-2391(89)90719-2","article-title":"Maxillomandibular advancement surgery in 23 patients with obstructive sleep apnea syndrome","volume":"47","author":"Waite","year":"1989","journal-title":"J Oral Maxillofac Surg"},{"key":"10.1111\/adj.12111-BIB0035|adj12111-cit-0035","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1007\/978-3-540-77786-1_10","volume-title":"Surgery for sleep disordered breathing","author":"Verse","year":"2010"},{"key":"10.1111\/adj.12111-BIB0036|adj12111-cit-0036","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1007\/s11325-008-0188-4","article-title":"CPAP compliance in patients with obstructive sleep apnea syndrome","volume":"12","author":"Yetkin","year":"2008","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0037|adj12111-cit-0037","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1513\/pats.200708-119MG","article-title":"Adherence to continuous positive airway pressure therapy: the challenge to effective treatment","volume":"5","author":"Weaver","year":"2008","journal-title":"Proc Am Thorac Soc"},{"key":"10.1111\/adj.12111-BIB0038|adj12111-cit-0038","first-page":"S172","article-title":"Treatment, airway and compliance effects of a titratable oral appliance","volume":"23","author":"Lowe","year":"2000","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0039|adj12111-cit-0039","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1177\/154405910808700917","article-title":"Obstructive sleep apnea therapy","volume":"87","author":"Hoekema","year":"2008","journal-title":"J Dent Res"},{"key":"10.1111\/adj.12111-BIB0040|adj12111-cit-0040","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1093\/sleep\/29.2.240","article-title":"Practice parameters for the treatment of snoring and obstructive sleep apnea with oral appliances: an update for 2005","volume":"29","author":"Kushida","year":"2006","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0041|adj12111-cit-0041","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1164\/ajrccm.163.6.2004213","article-title":"A randomized, controlled study of a mandibular advancement splint for obstructive sleep apnea","volume":"163","author":"Mehta","year":"2001","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0042|adj12111-cit-0042","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1111\/j.1365-2869.2008.00645.x","article-title":"Mandibular advancement appliance for obstructive sleep apnoea: results of a randomised placebo controlled trial using parallel group design","volume":"17","author":"Petri","year":"2008","journal-title":"J Sleep Res"},{"key":"10.1111\/adj.12111-BIB0043|adj12111-cit-0043","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1007\/s11325-003-0119-3","article-title":"A prospective randomized study comparing two different degrees of mandibular advancement with a dental appliance in treatment of severe obstructive sleep apnea","volume":"7","author":"Walker-Engstrom","year":"2003","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0044|adj12111-cit-0044","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1007\/s11325-011-0496-y","article-title":"The efficacy of oral appliances in the treatment of severe obstructive sleep apnea","volume":"15","author":"Lam","year":"2011","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0045|adj12111-cit-0045","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1093\/sleep\/27.4.761","article-title":"Rapid maxillary expansion in children with obstructive sleep apnea syndrome","volume":"27","author":"Pirelli","year":"2004","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0046|adj12111-cit-0046","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s11325-006-0084-8","article-title":"Review of oral appliances for treatment of sleep-disordered breathing","volume":"11","author":"Hoffstein","year":"2007","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0047|adj12111-cit-0047","doi-asserted-by":"crossref","first-page":"934","DOI":"10.1093\/sleep\/27.5.934","article-title":"Oral appliance therapy reduces blood pressure in obstructive sleep apnea: a randomized, controlled trial","volume":"27","author":"Gotsopoulos","year":"2004","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0048|adj12111-cit-0048","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1164\/rccm.200204-342OC","article-title":"Effect of vertical dimension on efficacy of oral appliance therapy in obstructive sleep apnea","volume":"166","author":"Pitsis","year":"2002","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0049|adj12111-cit-0049","first-page":"w13276","article-title":"Mandibular advancement splints for the treatment of sleep apnea syndrome","volume":"141","author":"Sutherland","year":"2011","journal-title":"Swiss Med Wkly"},{"key":"10.1111\/adj.12111-BIB0050|adj12111-cit-0050","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1007\/s00784-009-0298-9","article-title":"Effects of an oral appliance with different mandibular protrusion positions at a constant vertical dimension on obstructive sleep apnea","volume":"14","author":"Aarab","year":"2010","journal-title":"Clin Oral Investig"},{"key":"10.1111\/adj.12111-BIB0051|adj12111-cit-0051","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1111\/j.1365-2869.2009.00738.x","article-title":"A randomized prospective long-term study of two oral appliances for sleep apnoea treatment","volume":"18","author":"Ghazal","year":"2009","journal-title":"J Sleep Res"},{"key":"10.1111\/adj.12111-BIB0052|adj12111-cit-0052","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/s11325-005-0038-6","article-title":"The effect of oral appliance therapy on blood pressure in patients with obstructive sleep apnea","volume":"10","author":"Otsuka","year":"2006","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0053|adj12111-cit-0053","first-page":"61","article-title":"Effect on blood pressure of oral appliance therapy for sleep apnea syndrome","volume":"19","author":"Yoshida","year":"2006","journal-title":"Int J Prosthodont"},{"key":"10.1111\/adj.12111-BIB0054|adj12111-cit-0054","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1183\/09031936.00148208","article-title":"Titrated mandibular advancement versus positive airway pressure for sleep apnoea","volume":"34","author":"Gagnadoux","year":"2009","journal-title":"Eur Respir J"},{"key":"10.1111\/adj.12111-BIB0055|adj12111-cit-0055","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1007\/s11325-006-0093-7","article-title":"Simulated driving in obstructive sleep apnoea-hypopnoea; effects of oral appliances and continuous positive airway pressure","volume":"11","author":"Hoekema","year":"2007","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0056|adj12111-cit-0056","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1378\/chest.121.3.739","volume":"121","author":"Walker-Engstrom","year":"2002","journal-title":"Chest"},{"key":"10.1111\/adj.12111-BIB0057|adj12111-cit-0057","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1378\/chest.113.4.992","article-title":"The efficacy of oral appliances in the treatment of persistent sleep apnea after uvulopalatopharyngoplasty","volume":"113","author":"Millman","year":"1998","journal-title":"Chest"},{"key":"10.1111\/adj.12111-BIB0058|adj12111-cit-0058","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1111\/j.1600-0501.2007.01343.x","article-title":"Implant-retained oral appliances: a novel treatment for edentulous patients with obstructive sleep apnea-hypopnea syndrome","volume":"18","author":"Hoekema","year":"2007","journal-title":"Clin Oral Implants Res"},{"key":"10.1111\/adj.12111-BIB0059|adj12111-cit-0059","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1007\/s11325-009-0302-2","article-title":"Orthoimplants: an alternative treatment for SAHS?","volume":"14","author":"De","year":"2010","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0060|adj12111-cit-0060","doi-asserted-by":"crossref","first-page":"978","DOI":"10.2319\/071311-449.1","article-title":"Microimplant-based mandibular advancement therapy for the treatment of snoring and obstructive sleep apnea: a prospective study","volume":"82","author":"Ngiam","year":"2012","journal-title":"Angle Orthod"},{"key":"10.1111\/adj.12111-BIB0061|adj12111-cit-0061","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1093\/sleep\/32.5.648","article-title":"Comparison of mandibular advancement splint and tongue stabilizing device in obstructive sleep apnea: a randomized controlled trial","volume":"32","author":"Deane","year":"2009","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0062|adj12111-cit-0062","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1093\/sleep\/34.4.469","article-title":"Comparative effects of two oral appliances on upper airway structure in obstructive sleep apnea","volume":"34","author":"Sutherland","year":"2011","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0063|adj12111-cit-0063","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1164\/rccm.2008167","article-title":"Mandibular advancement devices: rate of contraindications in 100 consecutive obstructive sleep apnea patients","volume":"166","author":"Petit","year":"2002","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0064|adj12111-cit-0064","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1007\/s11325-008-0244-0","article-title":"Obstructive sleep apnoea and periodontitis: a novel association?","volume":"13","author":"Gunaratnam","year":"2009","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0065|adj12111-cit-0065","first-page":"339","article-title":"Prevalence of temporomandibular disorders in obstructive sleep apnea patients referred for oral appliance therapy","volume":"23","author":"Cunali","year":"2009","journal-title":"J Orofac Pain"},{"key":"10.1111\/adj.12111-BIB0066|adj12111-cit-0066","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1093\/sleep\/32.6.779","article-title":"Sleep disorders and their association with laboratory pain sensitivity in temporomandibular joint disorder","volume":"32","author":"Smith","year":"2009","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0067|adj12111-cit-0067","doi-asserted-by":"crossref","first-page":"1270","DOI":"10.1378\/chest.125.4.1270","article-title":"Mandibular advancement devices in 630 men and women with obstructive sleep apnea and snoring: tolerability and predictors of treatment success","volume":"125","author":"Marklund","year":"2004","journal-title":"Chest"},{"key":"10.1111\/adj.12111-BIB0068|adj12111-cit-0068","doi-asserted-by":"crossref","first-page":"439","DOI":"10.5664\/JCSM.1300","article-title":"Comparison of adjustable and fixed oral appliances for the treatment of obstructive sleep apnea","volume":"7","author":"Lettieri","year":"2011","journal-title":"J Clin Sleep Med"},{"key":"10.1111\/adj.12111-BIB0069|adj12111-cit-0069","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1093\/sleep\/24.5.538","article-title":"Influence of sleep posture on response to oral appliance therapy for sleep apnea syndrome","volume":"24","author":"Yoshida","year":"2001","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0070|adj12111-cit-0070","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/S0022-3913(08)60067-0","article-title":"Ten-year follow-up of mandibular advancement devices for the management of snoring and sleep apnea","volume":"99","author":"Jauhar","year":"2008","journal-title":"J Prosthet Dent"},{"key":"10.1111\/adj.12111-BIB0071|adj12111-cit-0071","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1067\/mod.2001.118782","article-title":"Cephalometric and physiologic predictors of the efficacy of an adjustable oral appliance for treating obstructive sleep apnea","volume":"120","author":"Liu","year":"2001","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1111\/adj.12111-BIB0072|adj12111-cit-0072","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/s11325-011-0484-2","article-title":"Cephalometry and prediction of oral appliance treatment outcome","volume":"16","author":"Ng","year":"2012","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0073|adj12111-cit-0073","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/S0889-5406(00)70169-7","article-title":"Cephalometric comparisons between Chinese and Caucasian patients with obstructive sleep apnea","volume":"117","author":"Liu","year":"2000","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1111\/adj.12111-BIB0074|adj12111-cit-0074","first-page":"666","article-title":"Oropharyngeal collapse predicts treatment response with oral appliance therapy in obstructive sleep apnea","volume":"29","author":"Ng","year":"2006","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0075|adj12111-cit-0075","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1093\/sleep\/31.4.543","article-title":"Influence of nasal resistance on oral appliance treatment outcome in obstructive sleep apnea","volume":"31","author":"Zeng","year":"2008","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0076|adj12111-cit-0076","doi-asserted-by":"crossref","first-page":"726","DOI":"10.1164\/rccm.200608-1205OC","article-title":"Use of flow-volume curves to predict oral appliance treatment outcome in obstructive sleep apnea","volume":"175","author":"Zeng","year":"2007","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0077|adj12111-cit-0077","first-page":"37","article-title":"Craniofacial phenotyping in obstructive sleep apnea-a novel quantitative photographic approach","volume":"32","author":"Lee","year":"2009","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0078|adj12111-cit-0078","first-page":"46","article-title":"Prediction of obstructive sleep apnea with craniofacial photographic analysis","volume":"32","author":"Lee","year":"2009","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0079|adj12111-cit-0079","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1016\/j.ajodo.2010.01.030","article-title":"Subjective efficacy of oral appliance design features in the management of obstructive sleep apnea: a systematic review","volume":"138","author":"Ahrens","year":"2010","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1111\/adj.12111-BIB0080|adj12111-cit-0080","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1093\/ejo\/cjq079","article-title":"A systematic review of the efficacy of oral appliance design in the management of obstructive sleep apnoea","volume":"33","author":"Ahrens","year":"2011","journal-title":"Eur J Orthod"},{"key":"10.1111\/adj.12111-BIB0081|adj12111-cit-0081","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1007\/s11325-012-0712-4","article-title":"Updates in oral appliance therapy for snoring and obstructive sleep apnea","volume":"17","author":"Chen","year":"2013","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0082|adj12111-cit-0082","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1159\/000029468","article-title":"Immediate intraoral adaptation of mandibular advancing appliances of thermoplastic material for the treatment of obstructive sleep apnea","volume":"67","author":"Schonhofer","year":"2000","journal-title":"Respiration"},{"key":"10.1111\/adj.12111-BIB0083|adj12111-cit-0083","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1080\/00016480310015984","article-title":"Pilot study of a novel mandibular advancement device for the control of snoring","volume":"124","author":"Vanderveken","year":"2004","journal-title":"Acta Otolaryngol"},{"key":"10.1111\/adj.12111-BIB0084|adj12111-cit-0084","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1164\/rccm.200701-114OC","article-title":"Comparison of a custom-made and a thermoplastic oral appliance for the treatment of mild sleep apnea","volume":"178","author":"Vanderveken","year":"2008","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0085|adj12111-cit-0085","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1007\/s11325-009-0304-0","article-title":"Side effects of boil and bite type oral appliance therapy in sleep apnea patients","volume":"14","author":"Tsuda","year":"2010","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0086|adj12111-cit-0086","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1097\/MCP.0b013e3283319b12","article-title":"Oral appliance treatment of obstructive sleep apnea: an update","volume":"15","author":"Chan","year":"2009","journal-title":"Curr Opin Pulm Med"},{"key":"10.1111\/adj.12111-BIB0087|adj12111-cit-0087","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1159\/000156861","article-title":"Mandibular advancement for obstructive sleep apnea: dose effect on apnea, long-term use and tolerance","volume":"76","author":"Gindre","year":"2008","journal-title":"Respiration"},{"key":"10.1111\/adj.12111-BIB0088|adj12111-cit-0088","doi-asserted-by":"crossref","first-page":"198","DOI":"10.5664\/jcsm.27485","article-title":"Effect of a titration polysomnogram on treatment success with a mandibular repositioning appliance","volume":"5","author":"Almeida","year":"2009","journal-title":"J Clin Sleep Med"},{"key":"10.1111\/adj.12111-BIB0089|adj12111-cit-0089","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1164\/ajrccm.161.2.9903079","article-title":"An oral elastic mandibular advancement device for obstructive sleep apnea","volume":"161","author":"Henke","year":"2000","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0090|adj12111-cit-0090","first-page":"507","article-title":"Effects of mandibular posture on obstructive sleep apnea severity and the temporomandibular joint in patients fitted with an oral appliance","volume":"25","author":"De","year":"2002","journal-title":"Sleep"},{"key":"10.1111\/adj.12111-BIB0091|adj12111-cit-0091","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/S0889-5406(03)00508-0","article-title":"Effect of titrated mandibular advancement and jaw opening on the upper airway in nonapneic men: a magnetic resonance imaging and cephalometric study","volume":"125","author":"Gao","year":"2004","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1111\/adj.12111-BIB0092|adj12111-cit-0092","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1378\/chest.117.4.1065","article-title":"Dose-dependent effects of mandibular advancement on pharyngeal mechanics and nocturnal oxygenation in patients with sleep-disordered breathing","volume":"117","author":"Kato","year":"2000","journal-title":"Chest"},{"key":"10.1111\/adj.12111-BIB0093|adj12111-cit-0093","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1016\/j.ajodo.2003.05.006","article-title":"Effects of an anteriorly titrated mandibular position on awake airway and obstructive sleep apnea severity","volume":"125","author":"Tsuiki","year":"2004","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1111\/adj.12111-BIB0094|adj12111-cit-0094","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1164\/ajrccm.165.8.2108056","article-title":"One-night mandibular advancement titration for obstructive sleep apnea syndrome: a pilot study","volume":"165","author":"Petelle","year":"2002","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0095|adj12111-cit-0095","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1164\/rccm.200310-1446OC","article-title":"Remotely controlled mandibular positioner predicts efficacy of oral appliances in sleep apnea","volume":"170","author":"Tsai","year":"2004","journal-title":"Am J Respir Crit Care Med"},{"key":"10.1111\/adj.12111-BIB0096|adj12111-cit-0096","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1183\/09031936.06.00077804","article-title":"Mandibular advancement and obstructive sleep apnoea: a method for determining effective mandibular protrusion","volume":"27","author":"Dort","year":"2006","journal-title":"Eur Respir J"},{"key":"10.1111\/adj.12111-BIB0097|adj12111-cit-0097","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1007\/s11325-008-0232-4","article-title":"Evaluation of a portable recording device (ApneaLink) for case selection of obstructive sleep apnea","volume":"13","author":"Chen","year":"2009","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0098|adj12111-cit-0098","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1093\/ejo\/25.4.371","article-title":"Dental and occlusal changes during mandibular advancement splint therapy in sleep disordered patients","volume":"25","author":"Robertson","year":"2003","journal-title":"Eur J Orthod"},{"key":"10.1111\/adj.12111-BIB0099|adj12111-cit-0099","doi-asserted-by":"crossref","first-page":"143","DOI":"10.5664\/jcsm.8978","article-title":"Long-term compliance and side effects of oral appliances used for the treatment of snoring and obstructive sleep apnea syndrome","volume":"1","author":"De","year":"2005","journal-title":"J Clin Sleep Med"},{"key":"10.1111\/adj.12111-BIB0100|adj12111-cit-0100","doi-asserted-by":"crossref","first-page":"30","DOI":"10.2319\/030309-122.1","article-title":"Five years of sleep apnea treatment with a mandibular advancement device","volume":"80","author":"Martinez-Gomis","year":"2010","journal-title":"Side effects and technical complications. Angle Orthod"},{"key":"10.1111\/adj.12111-BIB0101|adj12111-cit-0101","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.ajodo.2006.10.031","article-title":"Three-dimensional computer assisted study model analysis of long-term oral-appliance wear","volume":"134","author":"Chen","year":"2008","journal-title":"Part 2. Side effects of oral appliances in obstructive sleep apnea patients. Am J Orthod Dentofacial Orthop"},{"key":"10.1111\/adj.12111-BIB0102|adj12111-cit-0102","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1007\/s11325-012-0695-1","article-title":"The incidence and prevalence of temporomandibular disorders and posterior open bite in patients receiving mandibular advancement device therapy for obstructive sleep apnea","volume":"17","author":"Perez","year":"2013","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0103|adj12111-cit-0103","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.2319\/012210-46.1","article-title":"An orthodontic oral appliance","volume":"80","author":"Marklund","year":"2010","journal-title":"Angle Orthod"},{"key":"10.1111\/adj.12111-BIB0104|adj12111-cit-0104","doi-asserted-by":"crossref","first-page":"866","DOI":"10.2319\/100107-470.1","article-title":"Changes in occlusal contact area during oral appliance therapy assessed on study models","volume":"78","author":"Ueda","year":"2008","journal-title":"Angle Orthod"},{"key":"10.1111\/adj.12111-BIB0105|adj12111-cit-0105","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/S0889-5406(03)00240-3","article-title":"Dental and skeletal changes after 4\u00a0years of obstructive sleep apnea treatment with a mandibular advancement device: a prospective, randomized study","volume":"124","author":"Ringqvist","year":"2003","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1111\/adj.12111-BIB0106|adj12111-cit-0106","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1007\/s00784-011-0555-6","article-title":"Long-term oral appliance therapy in obstructive sleep apnea syndrome: a controlled study on temporomandibular side effects","volume":"16","author":"Doff","year":"2012","journal-title":"Clin Oral Investig"},{"key":"10.1111\/adj.12111-BIB0107|adj12111-cit-0107","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1007\/s11325-009-0257-3","article-title":"Systematic assessment of the impact of oral appliance therapy on the temporomandibular joint during treatment of obstructive sleep apnea: long-term evaluation","volume":"13","author":"Giannasi","year":"2009","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0108|adj12111-cit-0108","doi-asserted-by":"crossref","first-page":"430e1","DOI":"10.1016\/j.ajodo.2008.12.013","article-title":"Effect of 2 jaw exercises on occlusal function in patients with obstructive sleep apnea during oral appliance therapy: a randomized controlled trial","volume":"135","author":"Ueda","year":"2009","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"10.1111\/adj.12111-BIB0109|adj12111-cit-0109","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1007\/s11325-010-0428-2","article-title":"Mandibular exercises improve mandibular advancement device therapy for obstructive sleep apnea","volume":"15","author":"Cunali","year":"2011","journal-title":"Sleep Breath"},{"key":"10.1111\/adj.12111-BIB0110|adj12111-cit-0110","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1378\/chest.120.1.162","article-title":"Mandibular advancement device in patients with obstructive sleep apnea: long-term effects on apnea and sleep","volume":"120","author":"Marklund","year":"2001","journal-title":"Chest"},{"key":"10.1111\/adj.12111-BIB0111|adj12111-cit-0111","first-page":"125","article-title":"Position paper on the use of mandibular advancement devices in adults with sleep-related breathing disorders","volume":"11","author":"Schwarting","year":"2007","journal-title":"A position paper of the German Society of Dental Sleep Medicine (Deutsche Gesellschaft Zahnaerztliche Schlafmedizin, DGZS). Sleep Breath"}],"container-title":["Australian Dental Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fadj.12111","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/onlinelibrary.wiley.com\/wol1\/doi\/10.1111\/adj.12111\/fullpdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,18]],"date-time":"2022-03-18T16:59:01Z","timestamp":1647622741000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/adj.12111"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,12]]},"references-count":111,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2013,12]]}},"URL":"https:\/\/doi.org\/10.1111\/adj.12111","relation":{},"ISSN":["0045-0421"],"issn-type":[{"value":"0045-0421","type":"print"}],"subject":[],"published":{"date-parts":[[2013,12]]}}}