{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,25]],"date-time":"2026-01-25T14:46:18Z","timestamp":1769352378838,"version":"3.49.0"},"reference-count":38,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2014,9,3]],"date-time":"2014-09-03T00:00:00Z","timestamp":1409702400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[2015,1]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>\n                    We performed a review of published literature comparing the i\u2010gel\n                    <jats:sup>\u2122<\/jats:sup>\n                    with other supraglottic airway devices in children. Sixty\u2010two articles were identified following a literature search; we included data from 14 randomised controlled trials and eight observational studies that compared i\u2010gel sizes 1\u20132.5 with other commonly used, equivalently\u2010sized, devices. The primary outcome in most studies was oropharyngeal leak pressure. In the 14 randomised trials the i\u2010gel performed the same as the comparator device in five trials, significantly better in eight studies (p\u00a0&lt;\u00a00.05) and significantly worse in one (p\u00a0&lt;\u00a00.01). Seven studies assessed fibreoptic views of the larynx through the device; two found significantly better views through the i\u2010gel. Three studies reported a shorter insertion time for the i\u2010gel, whereas two reported a longer time. Insertion success rate, gastric tube placement and complications were similar for all the devices. Seven of the eight observational studies measured average oropharyngeal leak pressures of 20\u201327\u00a0cmH\n                    <jats:sub>2<\/jats:sub>\n                    O and all had first\u2010time insertion success rates exceeding 90%. We conclude that the i\u2010gel is at least equivalent to other supraglottic airway devices currently available for use in children, and may enable a higher oropharyngeal leak pressure and an improved fibreoptic view of the glottis.\n                  <\/jats:p>","DOI":"10.1111\/anae.12830","type":"journal-article","created":{"date-parts":[[2014,9,3]],"date-time":"2014-09-03T10:17:53Z","timestamp":1409739473000},"page":"84-92","source":"Crossref","is-referenced-by-count":24,"title":["A performance comparison of the paediatric i\u2010gel\n                    <sup>\u2122<\/sup>\n                    with other supraglottic airway devices"],"prefix":"10.1111","volume":"70","author":[{"given":"P.","family":"Smith","sequence":"first","affiliation":[{"name":"Department of Anaesthetics Great Ormond Street Hospital NHS Foundation Trust London UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C. R.","family":"Bailey","sequence":"additional","affiliation":[{"name":"Department of Anaesthetics Guys and St. Thomas' NHS Foundation Trust London UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2014,9,3]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2009.02997.x"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1213\/01.ANE.0000134798.00069.2B"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.d5928"},{"key":"e_1_2_7_5_1","first-page":"664","article-title":"Avoiding bias in observational studies","volume":"106","author":"Hammer GP","year":"2009","journal-title":"Deutsches Arzteblatt International"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2001.00649.x"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2011.03757.x"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.4103\/1658-354X.101212"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.4103\/0259-1162.108305"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/pan.12078"},{"key":"e_1_2_7_11_1","first-page":"231","article-title":"A comparison of the i\u2010gel with the LMA Supreme in non\u2010paralysed anaesthetized children. EUROANAESTHESIA 2011: the European Anaesthesiology Congress 19AP2\u20108","volume":"28","author":"Francksen H","year":"2011","journal-title":"European Journal of Anaesthesiology"},{"key":"e_1_2_7_12_1","first-page":"267","article-title":"Comparison of LMA\u2010Supreme and i\u2010gel in children: difficult airway scenario. EUROANAESTHESIA 2011: the European Anaesthesiology Congress 19AP3\u20109","volume":"28","author":"Kus A","year":"2011","journal-title":"European Journal of Anaesthesiology"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2012.02765.x"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00540-012-1477-4"},{"key":"e_1_2_7_15_1","first-page":"208","article-title":"Comparison of the efficacies of I\u2010gel and LMA\u2010ProSeal for airway management in pediatric patients","volume":"43","author":"Tokgoz O","year":"2013","journal-title":"Turkish Journal of Medical Sciences"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.4103\/1947-2714.101983"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2012.07072.x"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/anae.12592"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e318219d619"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2012.03893.x"},{"issue":"2","key":"e_1_2_7_21_1","first-page":"ii298","article-title":"I\u2010gel (supraglottic airway device) in pediatric ophthalmic anaesthesiology","volume":"108","author":"Rylov P","year":"2012","journal-title":"British Journal of Anaesthesia"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2008.01869.x"},{"key":"e_1_2_7_23_1","first-page":"258","article-title":"Airway management in anesthetized small children using the pediatric i\u2010gel and classic laryngeal mask airway. EUROANAESTHESIA 2011: the European Anaesthesiology Congress 19AP6\u20103","volume":"28","author":"Lee J","year":"2011","journal-title":"European Journal of Anaesthesiology"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00540-011-1322-1"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1136\/emermed-2012-201570"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aei167"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03014975"},{"key":"e_1_2_7_28_1","first-page":"457","article-title":"A proposed fiber\u2010optic scoring system to standardize the assessment of laryngeal mask airway position","volume":"76","author":"Brimacombe J","year":"1993","journal-title":"Anesthesia and Analgesia"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/79.6.710"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1097\/EJA.0b013e32835f9969"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003643-201106001-00481"},{"issue":"2","key":"e_1_2_7_32_1","first-page":"ii303","article-title":"Pediatric i\u2010gel use in 100 children","volume":"108","author":"Gil JAL","year":"2012","journal-title":"British Journal of Anaesthesia"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2011.06884.x"},{"key":"e_1_2_7_34_1","first-page":"107","article-title":"Tracheal compression caused by oversized i\u2010gel in children","volume":"79","author":"Agnoletti V","year":"2013","journal-title":"Minerva Anestesiologica"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2011.07024.x"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.4103\/0970-9185.98359"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.4097\/kjae.2013.65.1.61"},{"key":"e_1_2_7_38_1","first-page":"e002467","article-title":"Randomised comparison of the effectiveness of the laryngeal mask supreme, i\u2010gel and current practice in the initial airway management of prehospital cardiac arrest (REVIVE\u2010Airways): a feasibility study research protocol","volume":"3","author":"Benger JR","year":"2013","journal-title":"British Medical Journal Open"},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2012.07155.x"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fanae.12830","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/anae.12830","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T20:43:54Z","timestamp":1761684234000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1111\/anae.12830"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,9,3]]},"references-count":38,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015,1]]}},"alternative-id":["10.1111\/anae.12830"],"URL":"https:\/\/doi.org\/10.1111\/anae.12830","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"value":"0003-2409","type":"print"},{"value":"1365-2044","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,9,3]]}}}