{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T09:06:13Z","timestamp":1794301573123,"version":"4.9.0"},"reference-count":23,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2017,3,24]],"date-time":"2017-03-24T00:00:00Z","timestamp":1490313600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[2017,7]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>\n                    An accurate and reproducible recording of laryngoscopic view at tracheal intubation is an important aspect of anaesthetic practice. Unlike direct laryngoscopy, in which the view achieved by the line of sight directly relates to the ease of intubating the trachea, videolaryngoscopy can create a situation in which the view is good, but intubation difficult or impossible. Communicating this to a subsequent anaesthetist is important. We compared three scoring systems: Cormack and Lehane;\n                    <jats:styled-content style=\"fixed-case\">POGO<\/jats:styled-content>\n                    (percentage of glottic opening); and the Fremantle score, as used by 74 critical care doctors rating 30 anonymised videos of videolaryngoscopic intubations. Accuracy (degree of agreement of score with an expert panel assessment) was higher for\n                    <jats:styled-content style=\"fixed-case\">POGO<\/jats:styled-content>\n                    (75.5%) and the Fremantle score (73.9%) than for Cormack and Lehane (65.4%; p &lt; 0.001). Intra\u2010rater reliability (mean free marginal Kappa for ordinal scores and mean Cronbach's Alpha for continuous score) was higher for Fremantle score (0.796) and Cormack and Lehane (0.773) than\n                    <jats:styled-content style=\"fixed-case\">POGO<\/jats:styled-content>\n                    (0.693). Inter\u2010rater reliability for Fremantle score (0.618) and\n                    <jats:styled-content style=\"fixed-case\">POGO<\/jats:styled-content>\n                    (0.614) were similar and higher than the inter\u2010rater reliability of Cormack and Lehane 0.464 (p &lt; 0.001). The higher accuracy and inter\u2010rater reliability of\n                    <jats:styled-content style=\"fixed-case\">POGO<\/jats:styled-content>\n                    and the Fremantle score suggest they are preferable to Cormack and Lehane for use when documenting videolaryngoscopy. The additional information about ease of intubation conveyed by the Fremantle score may support its routine use in recording videolaryngoscopic intubation.\n                  <\/jats:p>","DOI":"10.1111\/anae.13837","type":"journal-article","created":{"date-parts":[[2017,3,24]],"date-time":"2017-03-24T09:32:26Z","timestamp":1490347946000},"page":"835-839","source":"Crossref","is-referenced-by-count":62,"title":["Accuracy, intra\u2010 and inter\u2010rater reliability of three scoring systems for the glottic view at videolaryngoscopy"],"prefix":"10.1111","volume":"72","author":[{"given":"E. J.","family":"O'Loughlin","sequence":"first","affiliation":[{"name":"Department of Anaesthesia and Pain Medicine Fiona Stanley Hospital Murdoch Western Australia"},{"name":"School of Medicine and Pharmacology University of Western Australia Nedlands Western Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. D.","family":"Swann","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia and Pain Medicine Fiona Stanley Hospital Murdoch Western Australia"},{"name":"School of Medicine and Pharmacology University of Western Australia Nedlands Western Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. D.","family":"English","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia Fremantle Hospital Fremantle Western Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Ramadas","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia and Pain Medicine Fiona Stanley Hospital Murdoch Western Australia"},{"name":"School of Medicine and Pharmacology University of Western Australia Nedlands Western Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,3,24]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1984.tb08932.x"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1553-2712.1998.tb02823.x"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03013137"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.1998.00605.x"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X0203000109"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.annemergmed.2010.05.035"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2011.06777.x"},{"key":"e_1_2_6_9_1","first-page":"123","article-title":"Use of Cormack and Lehane grading with videolaryngoscopy","volume":"41","author":"Gray H","year":"2013","journal-title":"Anaesthesia and Intensive Care"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2011.06685.x"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00540-012-1534-z"},{"key":"e_1_2_6_12_1","first-page":"122","article-title":"Scoring systems for videolaryngoscopes","volume":"41","author":"Bradley WP","year":"2013","journal-title":"Anaesthesia and Intensive Care"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199712000-00005"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2011.06891.x"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/ANA.0000000000000224"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.joms.2015.06.156"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X1204000417"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1245\/s10434-009-0654-7"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.2000.01270.x"},{"key":"e_1_2_6_20_1","unstructured":"StatsToDo.http:\/\/www.statstodo.com\/CohenKappa_Pgm.php(accessed 19\/05\/2016)."},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03022626"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1080\/10903120590924663"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/anae.13413"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1111\/anae.13729"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fanae.13837","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/anae.13837","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T16:17:23Z","timestamp":1761668243000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1111\/anae.13837"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,24]]},"references-count":23,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2017,7]]}},"alternative-id":["10.1111\/anae.13837"],"URL":"https:\/\/doi.org\/10.1111\/anae.13837","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"value":"0003-2409","type":"print"},{"value":"1365-2044","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,24]]}}}