{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T09:45:57Z","timestamp":1783158357080,"version":"3.54.6"},"reference-count":16,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2014,6,6]],"date-time":"2014-06-06T00:00:00Z","timestamp":1402012800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["ANZ Journal of Surgery"],"published-print":{"date-parts":[[2014,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>The rotational alignment of the femoral component in total knee arthroplasty (<jats:styled-content style=\"fixed-case\">TKA<\/jats:styled-content>) is regarded as being one of the critical factors associated with its long\u2010term success. Traditionally, the femoral component is aligned parallel to the transepicondylar axis (<jats:styled-content style=\"fixed-case\">TEA<\/jats:styled-content>), perpendicular to the Whiteside's line (<jats:styled-content style=\"fixed-case\">WL<\/jats:styled-content>) or at 3 degrees external rotation to the posterior condylar line (PCL). The aim of this study was to use magnetic resonance imaging (<jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content>) to evaluate the relationship between these anatomical axes used for femoral component rotation (<jats:styled-content style=\"fixed-case\">TEA<\/jats:styled-content> to <jats:styled-content style=\"fixed-case\">WL<\/jats:styled-content> and PCL to <jats:styled-content style=\"fixed-case\">TEA<\/jats:styled-content>) and identify if any of these relationships were influenced by age, sex or coronal axial deformity (mechanical axis).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Two hundred and sixty\u2010five patients undergoing preoperative <jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content> for patient\u2010specific jigs <jats:styled-content style=\"fixed-case\">TKA<\/jats:styled-content> were included in our study. The <jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content> data were then analysed via preoperative planning software, and values relating to <jats:styled-content style=\"fixed-case\">WL<\/jats:styled-content>, <jats:styled-content style=\"fixed-case\">TEA<\/jats:styled-content>, PCL and coronal axial alignment were generated.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The mean age was 66.0 \u00b1 8.7 years. There were 102 men and 163 women. The average mechanical axis (coronal deformity) was 4.2 \u00b1 6.1 degrees of varus. <jats:styled-content style=\"fixed-case\">TEA<\/jats:styled-content> compared with <jats:styled-content style=\"fixed-case\">WL<\/jats:styled-content> was on average 92.6 \u00b1 2.3 degrees. <jats:styled-content style=\"fixed-case\">PCL<\/jats:styled-content> was on average 2.3 \u00b1 1.8 degrees internally rotated to the <jats:styled-content style=\"fixed-case\">TEA<\/jats:styled-content>. The <jats:styled-content style=\"fixed-case\">PCL<\/jats:styled-content> was more internally rotated in women (<jats:italic>P<\/jats:italic> &lt; 0.01) and valgus (<jats:italic>P<\/jats:italic> &lt; 0.001) knees. There was no significant relationship between age or varus knees when comparing <jats:styled-content style=\"fixed-case\">TEA<\/jats:styled-content> to <jats:styled-content style=\"fixed-case\">WL<\/jats:styled-content> (<jats:italic>P<\/jats:italic> &gt; 0.1) and <jats:styled-content style=\"fixed-case\">PCL<\/jats:styled-content> to <jats:styled-content style=\"fixed-case\">TEA<\/jats:styled-content> (<jats:italic>P<\/jats:italic> &gt; 0.1).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Our study shows that the previously assumed values for rotational alignment of the femoral component may need to be reviewed. The use of advanced preoperative imaging (e.g. <jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content>) may aid to overcome this variability and assist surgeons in planning femoral component alignment in <jats:styled-content style=\"fixed-case\">TKA<\/jats:styled-content>.<\/jats:p><\/jats:sec>","DOI":"10.1111\/ans.12708","type":"journal-article","created":{"date-parts":[[2014,6,6]],"date-time":"2014-06-06T06:07:38Z","timestamp":1402034858000},"page":"852-855","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Defining distal femoral anatomy for rotational alignment in total knee arthroplasty: a magnetic resonance imaging\u2010based study"],"prefix":"10.1111","volume":"84","author":[{"given":"Jeevaka E.","family":"Amaranath","sequence":"first","affiliation":[{"name":"Department of Orthopaedics Nepean Public Hospital  Penrith New South Wales Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Terence R.","family":"Moopanar","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Nepean Public Hospital  Penrith New South Wales Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rami M.","family":"Sorial","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics Nepean Public Hospital\/Nepean Private Hospital The University of Sydney  Penrith New South Wales Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2014,6,6]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199301000-00008"},{"key":"e_1_2_5_3_1","first-page":"152","article-title":"Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: 10\u2010year follow\u2010up of Miller\u2010Galante I knees","volume":"14","author":"Matsuda S","year":"2001","journal-title":"Am. J. Knee Surg."},{"key":"e_1_2_5_4_1","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1097\/00003086-199302000-00027","article-title":"The effects of axial rotation alignment of the femoral component on knee stability and patella tracking in total knee arthroplasty demonstrated on autopsy specimens","volume":"287","author":"Anouchi YS","year":"1993","journal-title":"Clin. Orthop."},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200200002-00011"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199910000-00005"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/BLO.0b013e3180dc92e7"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otsr.2009.04.011"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1001\/jama.286.2.188"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.4081\/or.2009.e26"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.knee.2005.01.004"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200011000-00010"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(98)90036-5"},{"key":"e_1_2_5_14_1","first-page":"168","article-title":"The anteroposterior axis for femoral rotational alignment in valgus total knee arthroplasty","volume":"321","author":"Whiteside LA","year":"1995","journal-title":"Clin. Orthop. Relat. Res."},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(05)80068-3"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0883-5403(03)00197-9"},{"key":"e_1_2_5_17_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.J.00772"}],"container-title":["ANZ Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Fans.12708","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/ans.12708","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T12:43:55Z","timestamp":1696337035000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/ans.12708"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,6,6]]},"references-count":16,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2014,11]]}},"alternative-id":["10.1111\/ans.12708"],"URL":"https:\/\/doi.org\/10.1111\/ans.12708","archive":["Portico"],"relation":{},"ISSN":["1445-1433","1445-2197"],"issn-type":[{"value":"1445-1433","type":"print"},{"value":"1445-2197","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,6,6]]},"assertion":[{"value":"2014-05-03","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2014-06-06","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}