{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,13]],"date-time":"2024-09-13T09:13:35Z","timestamp":1726218815654},"reference-count":13,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2012,12,14]],"date-time":"2012-12-14T00:00:00Z","timestamp":1355443200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["obgyn.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Obstet Gynecol Scand"],"published-print":{"date-parts":[[2013,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Electrothermal injuries in monopolar laparoscopy may derive indirectly, but rarely, from capacitive coupling releasing stray currents into neighboring non\u2010targeted tissues, with intact instrument insulation. Since 2007, seven episodes of indirect electrosurgical damage to non\u2010targeted tissues have been observed in our gynecological practice, including incidental coagulative necrosis of appendix, Fallopian tube, cystic pedicle, and broad ligament stump. Such an electrical response becomes greater where there is increased contact with the cystic wall (cysts &lt;3\u00a0cm in diameter). Appropriate measures are available for minimizing capacitive coupling specifically caused by monopolar electrocautery. Thorough staff training, regular safety inspections, and strict procedure performance should exist to minimize such risks and injuries.<\/jats:p>","DOI":"10.1111\/aogs.12049","type":"journal-article","created":{"date-parts":[[2012,11,29]],"date-time":"2012-11-29T18:32:14Z","timestamp":1354213934000},"page":"238-241","update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Indirect electrical injuries from capacitive coupling: a rarely mentioned electrosurgical complication in monopolar laparoscopy"],"prefix":"10.1111","volume":"92","author":[{"given":"Qiang","family":"Liu","sequence":"first","affiliation":[{"name":"Department of Minimally Invasive Gynecology Specialist Clinic Affiliated to the Fourth Military Medical University Xi'an China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xue\u2010Bing","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Minimally Invasive Gynecology Specialist Clinic Affiliated to the Fourth Military Medical University Xi'an China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,12,14]]},"reference":[{"key":"e_1_2_5_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0929-6646(10)60049-6"},{"key":"e_1_2_5_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s004649900769"},{"key":"e_1_2_5_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9610(99)00267-6"},{"key":"e_1_2_5_5_1","first-page":"311","article-title":"Laparoscopic electrosurgical injuries: survey results and their implications","volume":"5","author":"Tucker RD","year":"1995","journal-title":"Surg Laparosc Endosc."},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-009-0601-5"},{"key":"e_1_2_5_7_1","first-page":"303","article-title":"Capacitive coupled stray currents during laparoscopic and endoscopic electrosurgical procedures","volume":"26","author":"Tucker RD","year":"1992","journal-title":"Biomed Instrum Technol."},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003081-199509000-00021"},{"key":"e_1_2_5_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0015-0282(03)01189-0"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1074-3804(05)81009-6"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/0029-7844(95)00411-4"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/00129689-200012000-00016"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0015-0282(00)01785-4"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijgo.2007.03.001"}],"container-title":["Acta Obstetricia et Gynecologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faogs.12049","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aogs.12049","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,30]],"date-time":"2023-10-30T12:47:35Z","timestamp":1698670055000},"score":1,"resource":{"primary":{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/10.1111\/aogs.12049"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,12,14]]},"references-count":13,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2013,2]]}},"alternative-id":["10.1111\/aogs.12049"],"URL":"https:\/\/doi.org\/10.1111\/aogs.12049","archive":["Portico"],"relation":{},"ISSN":["0001-6349","1600-0412"],"issn-type":[{"value":"0001-6349","type":"print"},{"value":"1600-0412","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,12,14]]},"assertion":[{"value":"2010-11-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2012-11-07","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2012-12-14","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}