{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T00:44:21Z","timestamp":1787013861874,"version":"build-2736575974"},"reference-count":25,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2015,9,1]],"date-time":"2015-09-01T00:00:00Z","timestamp":1441065600000},"content-version":"tdm","delay-in-days":768,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2014,4]]},"DOI":"10.1111\/aor.12139","type":"journal-article","created":{"date-parts":[[2013,7,26]],"date-time":"2013-07-26T05:37:23Z","timestamp":1374817043000},"page":"316-326","source":"Crossref","is-referenced-by-count":27,"title":["Analysis of Pressure Head-Flow Loops of Pulsatile Rotodynamic Blood Pumps"],"prefix":"10.1111","volume":"38","author":[{"given":"Silje E.","family":"Jahren","sequence":"first","affiliation":[{"name":"ARTORG Center for Biomedical Research; University of Bern; Bern USA"},{"name":"Institute for Dynamic Systems and Control; ETH Zurich; Zurich Switzerland USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gregor","family":"Ochsner","sequence":"additional","affiliation":[{"name":"Institute for Dynamic Systems and Control; ETH Zurich; Zurich Switzerland USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fangjun","family":"Shu","sequence":"additional","affiliation":[{"name":"Mechanical and Aerospace Engineering Department; New Mexico State University; Las Cruces NM USA"},{"name":"Department of Biomedical Engineering; Carnegie Mellon University; Pittsburgh PA USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raffael","family":"Amacher","sequence":"additional","affiliation":[{"name":"Institute for Dynamic Systems and Control; ETH Zurich; Zurich Switzerland USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James F.","family":"Antaki","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering; Carnegie Mellon University; Pittsburgh PA USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stijn","family":"Vandenberghe","sequence":"additional","affiliation":[{"name":"ARTORG Center for Biomedical Research; University of Bern; Bern USA"},{"name":"Department of Biomedical Engineering; Carnegie Mellon University; Pittsburgh PA USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2013,7,25]]},"reference":[{"key":"10.1111\/aor.12139-BIB0001|aor12139-cit-0001","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1016\/j.medengphy.2011.04.010","article-title":"A review of clinical ventricular assist devices","volume":"33","author":"Timms","year":"2011","journal-title":"Med Eng Phys"},{"key":"10.1111\/aor.12139-BIB0002|aor12139-cit-0002","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1177\/039139880202501107","article-title":"The heart-pump interaction: effects of a microaxial blood pump","volume":"25","author":"Stolinski","year":"2002","journal-title":"Int J Artif Organs"},{"key":"10.1111\/aor.12139-BIB0003|aor12139-cit-0003","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1098\/rsfs.2010.0039","article-title":"Computational modeling and evaluation of cardiovascular response under pulsatile impeller pump support","volume":"1","author":"Shi","year":"2011","journal-title":"Interface Focus"},{"key":"10.1111\/aor.12139-BIB0004|aor12139-cit-0004","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1109\/10.46252","article-title":"Design and control of the atrio-aortic left ventricular assist device based on O2 consumption","volume":"37","author":"Drzewiecki","year":"1990","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1111\/aor.12139-BIB0005|aor12139-cit-0005","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1111\/j.1525-1594.1992.tb00293.x","article-title":"Noninvasive monitoring of rotary blood pumps: necessity, possibilities, and limitations","volume":"16","author":"Schima","year":"1992","journal-title":"Artif Organs"},{"key":"10.1111\/aor.12139-BIB0006|aor12139-cit-0006","doi-asserted-by":"crossref","DOI":"10.1016\/j.jtcvs.2012.12.048","article-title":"Control of ventricular unloading using an electrocardiogram-synchronized Thoratec paracorporeal ventricular assist device","author":"Amacher","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1111\/aor.12139-BIB0007|aor12139-cit-0007","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1111\/j.1525-1594.2009.00755.x","article-title":"A mathematical model to evaluate control strategies for mechanical circulatory support","volume":"33","author":"Cox","year":"2009","journal-title":"Artif Organs"},{"key":"10.1111\/aor.12139-BIB0008|aor12139-cit-0008","first-page":"29","article-title":"Performance optimization of left ventricular assistance-a computer model study","volume":"39","author":"Platt","year":"1993","journal-title":"ASAIO J"},{"key":"10.1111\/aor.12139-BIB0009|aor12139-cit-0009","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1111\/j.1525-1594.2006.00276.x","article-title":"In vivo assessment of a rotary left ventricular device-induced artifical pulse in the proximal and distal aorta","volume":"30","author":"Bourque","year":"2006","journal-title":"Artif Organs"},{"key":"10.1111\/aor.12139-BIB0010|aor12139-cit-0010","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1097\/MAT.0b013e31805b7e39","article-title":"Left ventricle load impedance control by apical VAD can help heart recovery and patient perfusion: a numerical study","volume":"53","author":"Colacino","year":"2007","journal-title":"ASAIO J"},{"key":"10.1111\/aor.12139-BIB0011|aor12139-cit-0011","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jtcvs.2008.07.032","article-title":"Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices","volume":"137","author":"Crow","year":"2009","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1111\/aor.12139-BIB0012|aor12139-cit-0012","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1016\/j.jtcvs.2012.02.015","article-title":"Pulsatile control of rotary blood pumps: does the modulation waveform matter?","volume":"144","author":"Pirbodaghi","year":"2012","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1111\/aor.12139-BIB0013|aor12139-cit-0013","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1007\/s10047-011-0573-9","article-title":"A novel counterpulsation mode of rotary left ventricular assist devices can enhance myocardial Perfusion","volume":"14","author":"Ando","year":"2011","journal-title":"J Artif Organs"},{"key":"10.1111\/aor.12139-BIB0014|aor12139-cit-0014","doi-asserted-by":"crossref","first-page":"E125","DOI":"10.1111\/j.1525-1594.2012.01448.x","article-title":"Effect of parameter variations on the hemodynamic response under rotary blood pump assistance","volume":"36","author":"Lim","year":"2012","journal-title":"Artif Organs"},{"key":"10.1111\/aor.12139-BIB0015|aor12139-cit-0015","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1111\/j.1525-1594.2010.01101.x","article-title":"Prediction of the external work of the native heart from the dynamic H-Q curves of the rotary blood pumps during left heart bypass","volume":"34","author":"Yokoyama","year":"2010","journal-title":"Artif Organs"},{"key":"10.1111\/aor.12139-BIB0016|aor12139-cit-0016","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1007\/BF02345135","article-title":"Optimum control of the Hemopump as a left-ventricular assist device","volume":"43","author":"He","year":"2005","journal-title":"Med Biol Eng Comput"},{"key":"10.1111\/aor.12139-BIB0017|aor12139-cit-0017","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1097\/01.mat.0000179251.40649.45","article-title":"Hemodynamic modes of ventricular assist with a rotary blood pump: continuous, pulsatile, and failure","volume":"51","author":"Vandenberghe","year":"2005","journal-title":"ASAIO J"},{"key":"10.1111\/aor.12139-BIB0018|aor12139-cit-0018","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1109\/TBME.2012.2230000","article-title":"A novel interface for hybrid mock circulations to evaluate ventricular assist devices","volume":"60","author":"Ochsner","year":"2013","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1111\/aor.12139-BIB0019|aor12139-cit-0019","doi-asserted-by":"crossref","unstructured":"Ochsner G Amacher R Schmid-Daners M Emulation of ventricular suction in a hybrid mock circulation Proc. European Control Conference 2013","DOI":"10.23919\/ECC.2013.6669530"},{"key":"10.1111\/aor.12139-BIB0020|aor12139-cit-0020","doi-asserted-by":"crossref","first-page":"H501","DOI":"10.1152\/ajpheart.00138.2005","article-title":"Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchers","volume":"289","author":"Burkhoff","year":"2005","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"10.1111\/aor.12139-BIB0021|aor12139-cit-0021","unstructured":"Meyns B Ventricular support with miniature rotary blood pump, an experimental study 1997"},{"key":"10.1111\/aor.12139-BIB0022|aor12139-cit-0022","first-page":"A44","article-title":"Electrical, hydrodynamic, and optical evaluation of pulsatile RBP application","volume":"30","author":"Vandenberghe","year":"2006","journal-title":"Artif Organs"},{"key":"10.1111\/aor.12139-BIB0023|aor12139-cit-0023","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1097\/MAT.0b013e3181e321da","article-title":"Biomechanics of the aortic valve in the continuous flow VAD-assisted heart","volume":"56","author":"May-Newman","year":"2010","journal-title":"ASAIO J"},{"key":"10.1111\/aor.12139-BIB0024|aor12139-cit-0024","article-title":"A robust reference signal generator for synchronized ventricular assist devices","author":"Amacher","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1111\/aor.12139-BIB0025|aor12139-cit-0025","doi-asserted-by":"crossref","first-page":"761","DOI":"10.1111\/j.1525-1594.2008.00628.x","article-title":"Physiological control of a rotary blood pump with selectable therapeutic options: control of pulsatility gradient","volume":"32","author":"Arndt","year":"2008","journal-title":"Artif Organs"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faor.12139","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2021,7,4]],"date-time":"2021-07-04T14:03:28Z","timestamp":1625407408000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aor.12139"}},"subtitle":["Analysis of HQ Loops"],"short-title":[],"issued":{"date-parts":[[2013,7,25]]},"references-count":25,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2014,4]]}},"URL":"https:\/\/doi.org\/10.1111\/aor.12139","relation":{},"ISSN":["0160-564X"],"issn-type":[{"value":"0160-564X","type":"print"}],"subject":[],"published":{"date-parts":[[2013,7,25]]}}}