{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T12:20:19Z","timestamp":1769170819722,"version":"3.49.0"},"reference-count":38,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2015,5,1]],"date-time":"2015-05-01T00:00:00Z","timestamp":1430438400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"CardioFluidMechanics","award":["EU FP7 293931"],"award-info":[{"award-number":["EU FP7 293931"]}]},{"name":"ERC STR","award":["307460"],"award-info":[{"award-number":["307460"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2015,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Cardiopulmonary bypass (<jats:styled-content style=\"fixed-case\">CPB<\/jats:styled-content>) procedure is employed to repair most congenital heart defects (<jats:styled-content style=\"fixed-case\">CHD<\/jats:styled-content>). Cannulation is a critical component of this procedure where the location and diameter of cannula controls the hemodynamic performance. State\u2010of\u2010the\u2010art computational studies of neonatal <jats:styled-content style=\"fixed-case\">CPB<\/jats:styled-content> employed an isolated aortic arch region by truncating the three\u2010dimensional (3<jats:styled-content style=\"fixed-case\">D<\/jats:styled-content>) patient\u2010specific cerebral system. The present work expanded these studies where the 3<jats:styled-content style=\"fixed-case\">D<\/jats:styled-content> patient\u2010specific <jats:styled-content style=\"fixed-case\">MRI<\/jats:styled-content> reconstruction of the cerebral system, including the <jats:styled-content style=\"fixed-case\">C<\/jats:styled-content>ircle of <jats:styled-content style=\"fixed-case\">W<\/jats:styled-content>illis (<jats:styled-content style=\"fixed-case\">CoW<\/jats:styled-content>), is integrated with a hypoplastic neonatal aortic arch. The inlet of the arterial cannula is assigned a steady velocity boundary condition of the <jats:styled-content style=\"fixed-case\">CPB<\/jats:styled-content> pump, while all outlets are modeled as resistance boundary conditions, thus allowing acute comparisons between different cannula configurations. Three\u2010dimensional (<jats:styled-content style=\"fixed-case\">3D<\/jats:styled-content>) flow simulations in the aortic arch model are performed at a Reynolds number of 2150 using an experimentally validated commercial solver. Results demonstrate that the inclusion of 3<jats:styled-content style=\"fixed-case\">D CoW<\/jats:styled-content> is essential to predict the accurate head\u2010neck blood perfusion and therefore critical in deciding the neonatal aortic cannulation strategy preoperatively. Using this integrated model two <jats:styled-content style=\"fixed-case\">CPB<\/jats:styled-content> configurations are studied, where the cannulas were placed at innominate artery (<jats:styled-content style=\"fixed-case\">IA<\/jats:styled-content>) (<jats:styled-content style=\"fixed-case\">IA<\/jats:styled-content>\u2010cannula configuration) and ductus arteriosus (<jats:styled-content style=\"fixed-case\">DA<\/jats:styled-content>) (<jats:styled-content style=\"fixed-case\">DA<\/jats:styled-content>\u2010cannula configuration). Configuration change produced significant differences in flow splits and local hemodynamics of blood flow throughout the whole aortic arch, neck and cerebral arteries. Percent flow rate differences between the <jats:styled-content style=\"fixed-case\">IA<\/jats:styled-content>\u2010 and <jats:styled-content style=\"fixed-case\">DA<\/jats:styled-content>\u2010cannula configurations are computed to be: 19%, for descending aorta, 198% for ascending aorta (perfusing coronary arteries), 91% for right anterior cerebral artery, and 68% for left anterior cerebral artery. Another important finding is the retrograde flow at vertebral arteries for <jats:styled-content style=\"fixed-case\">IA<\/jats:styled-content>\u2010cannula configuration, but not for <jats:styled-content style=\"fixed-case\">DA<\/jats:styled-content>\u2010cannula. These results may help to translate better neonatal arterial cannulae design for minimizing cerebral complications during <jats:styled-content style=\"fixed-case\">CPB<\/jats:styled-content> procedures.<\/jats:p>","DOI":"10.1111\/aor.12468","type":"journal-article","created":{"date-parts":[[2015,5,2]],"date-time":"2015-05-02T04:28:55Z","timestamp":1430540935000},"source":"Crossref","is-referenced-by-count":13,"title":["Computational Modeling of Neonatal Cardiopulmonary Bypass Hemodynamics With Full <scp>C<\/scp>ircle of <scp>W<\/scp>illis Anatomy"],"prefix":"10.1111","volume":"39","author":[{"given":"Senol","family":"Piskin","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering Koc University  Istanbul Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akif","family":"\u00dcndar","sequence":"additional","affiliation":[{"name":"Pediatric Cardiovascular Research Center Department of Pediatrics, Surgery and Bioengineering Penn State Hershey College of Medicine  Hershey PA USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kerem","family":"Pekkan","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering Koc University  Istanbul Turkey"},{"name":"Department of Biomedical Engineering Carnegie Mellon University  Pittsburgh PA USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2015,5]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-013-0857-8"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/aor.12262"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-014-1064-y"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/aor.12094"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2012.11.004"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2012.10.029"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2009.00848.x"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2009.00938.x"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.2978988"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2012.03.053"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.2011.01433.x"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2013.11.005"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2014.03.039"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2014.02.039"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-010-0132-1"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jneumeth.2011.08.018"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2012.08.007"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2006.05.065"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2013.10.039"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2012.05.135"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(03)01072-5"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2008.10.043"},{"key":"e_1_2_7_24_1","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1051\/ject\/201042212","article-title":"Monitoring microemboli during cardiopulmonary bypass with the EDAC quantifier","volume":"42","author":"Lynch JE","year":"2010","journal-title":"J Extra Corpor Technol"},{"key":"e_1_2_7_25_1","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1051\/ject\/201143107","article-title":"In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters","volume":"43","author":"Liu S","year":"2011","journal-title":"J Extra Corpor Technol"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13239-010-0029-z"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0895-6111(02)00020-4"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2010.11.010"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0060271"},{"key":"e_1_2_7_30_1","first-page":"420","article-title":"Pulsatile venous waveform quality in Fontan circulation\u2010clinical implications, venous assists options and the future","volume":"12","author":"Kocyildirim E","year":"2012","journal-title":"Anadolu Kardiyol Derg"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.1351807"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-009-9650-0"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2014.06.021"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2007.12.059"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2011.05.033"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1080\/10255842.2011.629616"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ppedcard.2010.06.005"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2014.08.012"},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.177.1.1770053"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faor.12468","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aor.12468","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T03:40:24Z","timestamp":1696477224000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aor.12468"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,5]]},"references-count":38,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2015,10]]}},"alternative-id":["10.1111\/aor.12468"],"URL":"https:\/\/doi.org\/10.1111\/aor.12468","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,5]]}}}