{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T16:14:38Z","timestamp":1790612078231,"version":"4.1.0"},"reference-count":30,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2016,1,27]],"date-time":"2016-01-27T00:00:00Z","timestamp":1453852800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100010101","name":"Taichung Veterans General Hospital","doi-asserted-by":"crossref","award":["1037321B"],"award-info":[{"award-number":["1037321B"]}],"id":[{"id":"10.13039\/501100010101","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100010101","name":"Taichung Veterans General Hospital","doi-asserted-by":"crossref","award":["1047303B"],"award-info":[{"award-number":["1047303B"]}],"id":[{"id":"10.13039\/501100010101","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2016,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Clinical implantation of clavicle hook plates is often used as a treatment for acromioclavicular joint dislocation. However, it is not uncommon to find patients that have developed acromion osteolysis or had peri\u2010implant fracture after hook plate fixation. With the aim of preventing complications or fixation failure caused by implantation of inappropriate clavicle hook plates, the present study investigated the biomechanics of clavicle hook plates made of different materials and with different hook depths in treating acromioclavicular joint dislocation, using finite element analysis (<jats:styled-content style=\"fixed-case\">FEA<\/jats:styled-content>). This study established four parts using computer models: the clavicle, acromion, clavicle hook plate, and screws, and these established models were used for <jats:styled-content style=\"fixed-case\">FEA<\/jats:styled-content>. Moreover, implantations of clavicle hook plates made of different materials (stainless steel and titanium alloy) and with different depths (12, 15, and 18\u2009mm) in patients with acromioclavicular joint dislocation were simulated in the biomechanical analysis. The results indicate that deeper implantation of the clavicle hook plate reduces stress on the clavicle, and also reduces the force applied to the acromion by the clavicle hook plate. Even though a clavicle hook plate made of titanium alloy (a material with a lower Young's modulus) reduces the force applied to the acromion by the clavicle hook plate, slightly higher stress on the clavicle may occur. The results obtained in this study provide a better reference for orthopedic surgeons in choosing different clavicle hook plates for surgery.<\/jats:p>","DOI":"10.1111\/aor.12679","type":"journal-article","created":{"date-parts":[[2016,1,27]],"date-time":"2016-01-27T13:34:47Z","timestamp":1453901687000},"page":"1062-1070","source":"Crossref","is-referenced-by-count":32,"title":["Biomechanical Analysis of Implanted Clavicle Hook Plates With Different Implant Depths and Materials in the Acromioclavicular Joint: A Finite Element Analysis Study"],"prefix":"10.1111","volume":"40","author":[{"given":"Cheng\u2010Hung","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Orthopedics Taichung Veterans General Hospital  Taichung Taiwan"},{"name":"Department of Biotechnology Hung Kuang University  Taichung Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng\u2010Min","family":"Shih","sequence":"additional","affiliation":[{"name":"Department of Orthopedics Taichung Veterans General Hospital  Taichung Taiwan"},{"name":"Rong Hsing Research Center for Translational Medicine National Chung Hsing University  Taichung Taiwan"},{"name":"Department of Biological Science and Technology National Chiao Tung University  Hsinchu Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kui\u2010Chou","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Orthopedics Taichung Veterans General Hospital  Taichung Taiwan"},{"name":"School of Medicine National Yang\u2010Ming University  Taipei Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kun\u2010Hui","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Orthopedics Taichung Veterans General Hospital  Taichung Taiwan"},{"name":"Department of Biomedical Engineering Hungkuang University  Taichung Taiwan"},{"name":"Department of Biomedical Engineering National Yang\u2010Ming University  Taipei Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li\u2010Kun","family":"Hung","sequence":"additional","affiliation":[{"name":"Department of Orthopedics Taichung Veterans General Hospital  Taichung Taiwan"},{"name":"Department of Orthopaedics Chiayi Branch Taichung Veterans General Hospital  Chiayi Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuo\u2010Chih","family":"Su","sequence":"additional","affiliation":[{"name":"Department of Medical Research Taichung Veterans General Hospital  Taichung Taiwan"},{"name":"Rong Hsing Research Center for Translational Medicine National Chung Hsing University  Taichung Taiwan"},{"name":"Department of Biomedical Engineering Hungkuang University  Taichung Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2016,1,27]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arthro.2012.11.023"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.5812\/traumamon.13728"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2005.10.017"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1186\/1749-799X-7-2"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2009.12.005"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.3113\/JSOA.2014.0147"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1186\/1749-799X-9-46"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.blo.0000203469.66055.6a"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1177\/230949900601400320"},{"key":"e_1_2_8_11_1","first-page":"e718","article-title":"Comparing hook plates and Kirschner tension band wiring for unstable lateral clavicle fractures","volume":"34","author":"Wu K","year":"2011","journal-title":"Orthopedics"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-009-0925-8"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0b013e318193d878"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1186\/1749-799X-9-6"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2009.12.012"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jse.2005.11.012"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2010.02.011"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1902\/jop.2009.090013"},{"key":"e_1_2_8_19_1","first-page":"59","article-title":"Finite element analysis of the effects of sizes of acetabular components on the initial stability of the acetabular cup","volume":"28","author":"Hsu JT","year":"2008","journal-title":"J Med Biol Eng"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1080\/10255842.2013.765410"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10237-013-0514-z"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1080\/10255842.2013.845175"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/817321"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-015-2890-8"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0034-1367050"},{"key":"e_1_2_8_26_1","first-page":"468","volume-title":"Finite Element Simulations with ANSYS Workbench 15","author":"Lee HH","year":"2014"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2012.01.015"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2007.11.016"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1142\/S0219519413500127"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-010-1613-0"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.84B8.13752"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1111%2Faor.12679","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1111\/aor.12679","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,24]],"date-time":"2023-09-24T12:55:04Z","timestamp":1695560104000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1111\/aor.12679"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1,27]]},"references-count":30,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2016,11]]}},"alternative-id":["10.1111\/aor.12679"],"URL":"https:\/\/doi.org\/10.1111\/aor.12679","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1,27]]}}}